Ambient atmospheric pressure Solution

STEP 0: Pre-Calculation Summary
Formula Used
Atmospheric Pressure = Pressure in Flushing Hole-(Net Force Acting on the Electrode*(2*ln(Radius of the Electrodes/Radius of Flushing Hole)))/(pi*(Radius of the Electrodes^2-Radius of Flushing Hole^2))
Patm = P1-(Fnet*(2*ln(R0/R1)))/(pi*(R0^2-R1^2))
This formula uses 1 Constants, 1 Functions, 5 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Functions Used
ln - The natural logarithm, also known as the logarithm to the base e, is the inverse function of the natural exponential function., ln(Number)
Variables Used
Atmospheric Pressure - (Measured in Pascal) - Atmospheric pressure, also known as barometric pressure, is the pressure within the atmosphere of Earth.
Pressure in Flushing Hole - (Measured in Pascal) - Pressure in Flushing Hole is the pressure in hole during EDM machining.
Net Force Acting on the Electrode - (Measured in Newton) - Net force acting on the electrode is the net force acting on the electrode.
Radius of the Electrodes - (Measured in Meter) - Radius of the electrodes is defined as the radius of the electrode used for unconventional machining by EDM.
Radius of Flushing Hole - (Measured in Meter) - Radius of flushing hole is the radius of flushing hole in EDM.
STEP 1: Convert Input(s) to Base Unit
Pressure in Flushing Hole: 176.66 Newton per Square Centimeter --> 1766600 Pascal (Check conversion ​here)
Net Force Acting on the Electrode: 6 Kilonewton --> 6000 Newton (Check conversion ​here)
Radius of the Electrodes: 5 Centimeter --> 0.05 Meter (Check conversion ​here)
Radius of Flushing Hole: 2 Centimeter --> 0.02 Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Patm = P1-(Fnet*(2*ln(R0/R1)))/(pi*(R0^2-R1^2)) --> 1766600-(6000*(2*ln(0.05/0.02)))/(pi*(0.05^2-0.02^2))
Evaluating ... ...
Patm = 99946.2938621456
STEP 3: Convert Result to Output's Unit
99946.2938621456 Pascal -->9.99462938621456 Newton per Square Centimeter (Check conversion ​here)
FINAL ANSWER
9.99462938621456 9.994629 Newton per Square Centimeter <-- Atmospheric Pressure
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rajat Vishwakarma
University Institute of Technology RGPV (UIT - RGPV), Bhopal
Rajat Vishwakarma has created this Calculator and 400+ more calculators!
Verifier Image
Vallurupalli Nageswara Rao Vignana Jyothi Institute of Engineering and Technology (VNRVJIET), Hyderabad
Sai Venkata Phanindra Chary Arendra has verified this Calculator and 300+ more calculators!

3 Net force acting on the electrode Calculators

Pressure in flushing hole net force electrode
​ Go Pressure in Flushing Hole = Atmospheric Pressure+(Net Force Acting on the Electrode*(2*ln(Radius of the Electrodes/Radius of Flushing Hole)))/(pi*(Radius of the Electrodes^2-Radius of Flushing Hole^2))
Net force acting on electrode
​ Go Net Force Acting on the Electrode = (pi*(Pressure in Flushing Hole-Atmospheric Pressure)*(Radius of the Electrodes^2-Radius of Flushing Hole^2))/(2*ln(Radius of the Electrodes/Radius of Flushing Hole))
Ambient atmospheric pressure
​ Go Atmospheric Pressure = Pressure in Flushing Hole-(Net Force Acting on the Electrode*(2*ln(Radius of the Electrodes/Radius of Flushing Hole)))/(pi*(Radius of the Electrodes^2-Radius of Flushing Hole^2))

Ambient atmospheric pressure Formula

Atmospheric Pressure = Pressure in Flushing Hole-(Net Force Acting on the Electrode*(2*ln(Radius of the Electrodes/Radius of Flushing Hole)))/(pi*(Radius of the Electrodes^2-Radius of Flushing Hole^2))
Patm = P1-(Fnet*(2*ln(R0/R1)))/(pi*(R0^2-R1^2))

What does the term Flushing mean in Electric Discharge Machining?

Flushing refers to the method in which the dielectric fluid flows between the tool and the work gap.The efficiency of machining depends to a greater extent on the efficiency of the flushing. The wear debris present in the spark gap should be removed as quickly as possible. With poor flushing there is a possibility of build-up of the machined particles in the gap resulting in the short-circuiting and lower material removal rates. Problems with improper flushing are: uneven and significant tool wear affecting accuracy and surface finish; reduced removal rates due to unstable machining conditions and arcing around regions with high concentration of debris. It is noted during an experimental study that there is an optimum dielectric flushing rate of about 13 ml/s while machining AISI O1 tool steel, where the crack density and average thickness of the recast layer are at a minimum.

How to Calculate Ambient atmospheric pressure?

Ambient atmospheric pressure calculator uses Atmospheric Pressure = Pressure in Flushing Hole-(Net Force Acting on the Electrode*(2*ln(Radius of the Electrodes/Radius of Flushing Hole)))/(pi*(Radius of the Electrodes^2-Radius of Flushing Hole^2)) to calculate the Atmospheric Pressure, The Ambient atmospheric pressure formula is defined as the pressure of the ambient area where electrode performs EDM. Atmospheric Pressure is denoted by Patm symbol.

How to calculate Ambient atmospheric pressure using this online calculator? To use this online calculator for Ambient atmospheric pressure, enter Pressure in Flushing Hole (P1), Net Force Acting on the Electrode (Fnet), Radius of the Electrodes (R0) & Radius of Flushing Hole (R1) and hit the calculate button. Here is how the Ambient atmospheric pressure calculation can be explained with given input values -> 0.000999 = 1766600-(6000*(2*ln(0.05/0.02)))/(pi*(0.05^2-0.02^2)).

FAQ

What is Ambient atmospheric pressure?
The Ambient atmospheric pressure formula is defined as the pressure of the ambient area where electrode performs EDM and is represented as Patm = P1-(Fnet*(2*ln(R0/R1)))/(pi*(R0^2-R1^2)) or Atmospheric Pressure = Pressure in Flushing Hole-(Net Force Acting on the Electrode*(2*ln(Radius of the Electrodes/Radius of Flushing Hole)))/(pi*(Radius of the Electrodes^2-Radius of Flushing Hole^2)). Pressure in Flushing Hole is the pressure in hole during EDM machining, Net force acting on the electrode is the net force acting on the electrode, Radius of the electrodes is defined as the radius of the electrode used for unconventional machining by EDM & Radius of flushing hole is the radius of flushing hole in EDM.
How to calculate Ambient atmospheric pressure?
The Ambient atmospheric pressure formula is defined as the pressure of the ambient area where electrode performs EDM is calculated using Atmospheric Pressure = Pressure in Flushing Hole-(Net Force Acting on the Electrode*(2*ln(Radius of the Electrodes/Radius of Flushing Hole)))/(pi*(Radius of the Electrodes^2-Radius of Flushing Hole^2)). To calculate Ambient atmospheric pressure, you need Pressure in Flushing Hole (P1), Net Force Acting on the Electrode (Fnet), Radius of the Electrodes (R0) & Radius of Flushing Hole (R1). With our tool, you need to enter the respective value for Pressure in Flushing Hole, Net Force Acting on the Electrode, Radius of the Electrodes & Radius of Flushing Hole and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!