Aquifer Thickness given Confined Aquifer Discharge with Base 10 Solution

STEP 0: Pre-Calculation Summary
Formula Used
Aquifer Thickness During Pumping = Discharge/((2.72*Coefficient of Permeability*Total Drawdown in Well)/(log((Radius of Influence/Radius of well),10)))
bp = Q/((2.72*Kw*st)/(log((Rw/r),10)))
This formula uses 1 Functions, 6 Variables
Functions Used
log - Logarithmic function is an inverse function to exponentiation., log(Base, Number)
Variables Used
Aquifer Thickness During Pumping - (Measured in Meter) - Aquifer Thickness During Pumping is the thickness of aquifer during pumping stage.
Discharge - (Measured in Cubic Meter per Second) - Discharge is the rate of flow of a liquid.
Coefficient of Permeability - (Measured in Meter per Second) - Coefficient of Permeability is the velocity in meters or centimeters per second of water through soils.
Total Drawdown in Well - (Measured in Meter) - The Total Drawdown in Well is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test.
Radius of Influence - (Measured in Meter) - Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table.
Radius of well - (Measured in Meter) - Radius of well is defined as the distance from center of well to its outer boundary.
STEP 1: Convert Input(s) to Base Unit
Discharge: 1.01 Cubic Meter per Second --> 1.01 Cubic Meter per Second No Conversion Required
Coefficient of Permeability: 1000 Centimeter per Second --> 10 Meter per Second (Check conversion ​here)
Total Drawdown in Well: 0.83 Meter --> 0.83 Meter No Conversion Required
Radius of Influence: 8.6 Meter --> 8.6 Meter No Conversion Required
Radius of well: 7.5 Meter --> 7.5 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
bp = Q/((2.72*Kw*st)/(log((Rw/r),10))) --> 1.01/((2.72*10*0.83)/(log((8.6/7.5),10)))
Evaluating ... ...
bp = 0.752689961365958
STEP 3: Convert Result to Output's Unit
0.752689961365958 Meter --> No Conversion Required
FINAL ANSWER
0.752689961365958 0.75269 Meter <-- Aquifer Thickness During Pumping
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

9 Aquifer Thickness Calculators

Thickness of Confined Aquifer given Discharge in Confined Aquifer
​ Go Aquifer Thickness During Pumping = Discharge/((2*pi*Coefficient of Permeability*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of well),e)))
Aquifer Thickness from Impermeable Layer given Discharge in Confined Aquifer
​ Go Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of well),e))/(2*pi*Coefficient of Permeability*Aquifer Thickness))
Aquifer Thickness given Depth of Water in Two Wells
​ Go Aquifer Thickness During Pumping = Discharge/((2.72*Coefficient of Permeability*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10)))
Aquifer Thickness from Impermeable Layer given Coefficient of Transmissibility
​ Go Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of well),e))/(2*pi*Coefficient of Transmissibility in Enviro. Eng.))
Aquifer Thickness given Confined Aquifer Discharge
​ Go Aquifer Thickness = Discharge/((2*pi*Coefficient of Permeability in Well Hydraulics*Total Drawdown in Well)/(log((Radius of Influence/Radius of well),e)))
Thickness of Confined Aquifer given Discharge in Confined Aquifer with Base 10
​ Go Aquifer Thickness During Pumping = Discharge/((2.72*Coefficient of Permeability in Well Hydraulics*(Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of well),10)))
Aquifer Thickness from Impermeable Layer given Discharge in Confined Aquifer with Base 10
​ Go Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of well),10))/(2.72*Coefficient of Permeability*Aquifer Thickness))
Aquifer Thickness from Impermeable Layer given Coefficient of Transmissibility with Base 10
​ Go Initial Aquifer Thickness = Depth of Water+((Discharge*log((Radius of Influence/Radius of well),10))/(2.72*Coefficient of Transmissibility in Enviro. Eng.))
Aquifer Thickness given Confined Aquifer Discharge with Base 10
​ Go Aquifer Thickness During Pumping = Discharge/((2.72*Coefficient of Permeability*Total Drawdown in Well)/(log((Radius of Influence/Radius of well),10)))

Aquifer Thickness given Confined Aquifer Discharge with Base 10 Formula

Aquifer Thickness During Pumping = Discharge/((2.72*Coefficient of Permeability*Total Drawdown in Well)/(log((Radius of Influence/Radius of well),10)))
bp = Q/((2.72*Kw*st)/(log((Rw/r),10)))

What is Aquifer?

An aquifer is an underground layer of water-bearing permeable rock, rock fractures or unconsolidated materials (gravel, sand, or silt). Groundwater can be extracted using a water well.

How to Calculate Aquifer Thickness given Confined Aquifer Discharge with Base 10?

Aquifer Thickness given Confined Aquifer Discharge with Base 10 calculator uses Aquifer Thickness During Pumping = Discharge/((2.72*Coefficient of Permeability*Total Drawdown in Well)/(log((Radius of Influence/Radius of well),10))) to calculate the Aquifer Thickness During Pumping, The Aquifer Thickness given Confined Aquifer Discharge with Base 10 is defined as the value of aquifer thickness when we have prior information of other parameters used. Aquifer Thickness During Pumping is denoted by bp symbol.

How to calculate Aquifer Thickness given Confined Aquifer Discharge with Base 10 using this online calculator? To use this online calculator for Aquifer Thickness given Confined Aquifer Discharge with Base 10, enter Discharge (Q), Coefficient of Permeability (Kw), Total Drawdown in Well (st), Radius of Influence (Rw) & Radius of well (r) and hit the calculate button. Here is how the Aquifer Thickness given Confined Aquifer Discharge with Base 10 calculation can be explained with given input values -> 0.75269 = 1.01/((2.72*10*0.83)/(log((8.6/7.5),10))).

FAQ

What is Aquifer Thickness given Confined Aquifer Discharge with Base 10?
The Aquifer Thickness given Confined Aquifer Discharge with Base 10 is defined as the value of aquifer thickness when we have prior information of other parameters used and is represented as bp = Q/((2.72*Kw*st)/(log((Rw/r),10))) or Aquifer Thickness During Pumping = Discharge/((2.72*Coefficient of Permeability*Total Drawdown in Well)/(log((Radius of Influence/Radius of well),10))). Discharge is the rate of flow of a liquid, Coefficient of Permeability is the velocity in meters or centimeters per second of water through soils, The Total Drawdown in Well is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test, Radius of Influence measured from the center of the well to the point where drawdown curve meets the original water table & Radius of well is defined as the distance from center of well to its outer boundary.
How to calculate Aquifer Thickness given Confined Aquifer Discharge with Base 10?
The Aquifer Thickness given Confined Aquifer Discharge with Base 10 is defined as the value of aquifer thickness when we have prior information of other parameters used is calculated using Aquifer Thickness During Pumping = Discharge/((2.72*Coefficient of Permeability*Total Drawdown in Well)/(log((Radius of Influence/Radius of well),10))). To calculate Aquifer Thickness given Confined Aquifer Discharge with Base 10, you need Discharge (Q), Coefficient of Permeability (Kw), Total Drawdown in Well (st), Radius of Influence (Rw) & Radius of well (r). With our tool, you need to enter the respective value for Discharge, Coefficient of Permeability, Total Drawdown in Well, Radius of Influence & Radius of well and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Aquifer Thickness During Pumping?
In this formula, Aquifer Thickness During Pumping uses Discharge, Coefficient of Permeability, Total Drawdown in Well, Radius of Influence & Radius of well. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Aquifer Thickness During Pumping = Discharge/((2*pi*Coefficient of Permeability*(Initial Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of well),e)))
  • Aquifer Thickness During Pumping = Discharge/((2.72*Coefficient of Permeability in Well Hydraulics*(Aquifer Thickness-Depth of Water))/(log((Radius of Influence/Radius of well),10)))
  • Aquifer Thickness During Pumping = Discharge/((2.72*Coefficient of Permeability*(Depth of Water 2-Depth of Water 1))/(log((Radial Distance at Observation Well 2/Radial Distance at Observation Well 1),10)))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!