Area for Siphon Throat Solution

STEP 0: Pre-Calculation Summary
Formula Used
Area for Siphon Throat = Volume Flow Rate/(Coefficient of Discharge*(2*Acceleration due to Gravity*Head of Liquid)^(1/2))
As = Q/(Cd*(2*g*H)^(1/2))
This formula uses 5 Variables
Variables Used
Area for Siphon Throat - (Measured in Square Meter) - Area for Siphon Throat is the area of the siphon from where the discharge is released.
Volume Flow Rate - (Measured in Cubic Meter per Second) - Volume Flow Rate is the volume of fluid that passes per unit of time.
Coefficient of Discharge - The Coefficient of Discharge or efflux coefficient is the ratio of the actual discharge to the theoretical discharge.
Acceleration due to Gravity - (Measured in Meter per Square Second) - Acceleration due to Gravity is acceleration gained by an object because of gravitational force.
Head of Liquid - (Measured in Meter) - The Head of Liquid is the height of a liquid column that corresponds to a particular pressure exerted by the liquid column from the base of its container.
STEP 1: Convert Input(s) to Base Unit
Volume Flow Rate: 1.5 Cubic Meter per Second --> 1.5 Cubic Meter per Second No Conversion Required
Coefficient of Discharge: 0.94 --> No Conversion Required
Acceleration due to Gravity: 9.8 Meter per Square Second --> 9.8 Meter per Square Second No Conversion Required
Head of Liquid: 15 Meter --> 15 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
As = Q/(Cd*(2*g*H)^(1/2)) --> 1.5/(0.94*(2*9.8*15)^(1/2))
Evaluating ... ...
As = 0.0930657197106071
STEP 3: Convert Result to Output's Unit
0.0930657197106071 Square Meter --> No Conversion Required
FINAL ANSWER
0.0930657197106071 0.093066 Square Meter <-- Area for Siphon Throat
(Calculation completed in 00.004 seconds)

Credits

Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

7 Controlling Sewer-Water Flow Calculators

Head given Area for Siphon Throat
Go Head of Liquid = (Volume Flow Rate/(Area for Siphon Throat*Coefficient of Discharge))^(2)*(1/(2*Acceleration due to Gravity))
Coefficient of Discharge given Area for Siphon Throat
Go Coefficient of Discharge = Volume Flow Rate/(Area for Siphon Throat*(2*Acceleration due to Gravity*Head of Liquid)^(1/2))
Area for Siphon Throat
Go Area for Siphon Throat = Volume Flow Rate/(Coefficient of Discharge*(2*Acceleration due to Gravity*Head of Liquid)^(1/2))
Discharge given Area for Siphon Throat
Go Volume Flow Rate = Area for Siphon Throat*Coefficient of Discharge*(2*Acceleration due to Gravity*Head of Liquid)^(1/2)
Depth of Flow over Weir given Flow Diversion
Go Depth of Flow Over Weir = (Volume Flow Rate/(3.32*(Length of Weir)^0.83))^(1/1.67)
Length of Weir given Flow Diversion
Go Length of Weir = (Volume Flow Rate/(3.32*Depth of Flow Over Weir^1.67))^(1/0.83)
Flow Diversion for Side Weir
Go Volume Flow Rate = 3.32*Length of Weir^(0.83)*Depth of Flow Over Weir^(1.67)

Area for Siphon Throat Formula

Area for Siphon Throat = Volume Flow Rate/(Coefficient of Discharge*(2*Acceleration due to Gravity*Head of Liquid)^(1/2))
As = Q/(Cd*(2*g*H)^(1/2))

What is siphon?

A siphon is any of a wide variety of devices that involve the flow of liquids through tubes. Pipelines called inverted siphons are used to carry sewage or stormwater under streams, highway cuts, or other depressions in the ground.

How to Calculate Area for Siphon Throat?

Area for Siphon Throat calculator uses Area for Siphon Throat = Volume Flow Rate/(Coefficient of Discharge*(2*Acceleration due to Gravity*Head of Liquid)^(1/2)) to calculate the Area for Siphon Throat, The Area for siphon throat formula is defined as the area of siphon from where the discharge is released. Area for Siphon Throat is denoted by As symbol.

How to calculate Area for Siphon Throat using this online calculator? To use this online calculator for Area for Siphon Throat, enter Volume Flow Rate (Q), Coefficient of Discharge (Cd), Acceleration due to Gravity (g) & Head of Liquid (H) and hit the calculate button. Here is how the Area for Siphon Throat calculation can be explained with given input values -> 0.093066 = 1.5/(0.94*(2*9.8*15)^(1/2)).

FAQ

What is Area for Siphon Throat?
The Area for siphon throat formula is defined as the area of siphon from where the discharge is released and is represented as As = Q/(Cd*(2*g*H)^(1/2)) or Area for Siphon Throat = Volume Flow Rate/(Coefficient of Discharge*(2*Acceleration due to Gravity*Head of Liquid)^(1/2)). Volume Flow Rate is the volume of fluid that passes per unit of time, The Coefficient of Discharge or efflux coefficient is the ratio of the actual discharge to the theoretical discharge, Acceleration due to Gravity is acceleration gained by an object because of gravitational force & The Head of Liquid is the height of a liquid column that corresponds to a particular pressure exerted by the liquid column from the base of its container.
How to calculate Area for Siphon Throat?
The Area for siphon throat formula is defined as the area of siphon from where the discharge is released is calculated using Area for Siphon Throat = Volume Flow Rate/(Coefficient of Discharge*(2*Acceleration due to Gravity*Head of Liquid)^(1/2)). To calculate Area for Siphon Throat, you need Volume Flow Rate (Q), Coefficient of Discharge (Cd), Acceleration due to Gravity (g) & Head of Liquid (H). With our tool, you need to enter the respective value for Volume Flow Rate, Coefficient of Discharge, Acceleration due to Gravity & Head of Liquid and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!