Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in Solution

STEP 0: Pre-Calculation Summary
Formula Used
Area = Inlet Capacity/(0.6*(2*Acceleration due to Gravity*Depth)^(1/2))
A = Qi/(0.6*(2*g*D)^(1/2))
This formula uses 4 Variables
Variables Used
Area - (Measured in Square Meter) - The area is the amount of two-dimensional space taken up by an object.
Inlet Capacity - (Measured in Cubic Meter per Second) - Inlet Capacity measures the flow in a sewer in terms of cubic meters of flow per day.
Acceleration due to Gravity - (Measured in Meter per Square Second) - Acceleration due to Gravity is acceleration gained by an object because of gravitational force.
Depth - (Measured in Meter) - Depth is the distance from the top or surface to the bottom of something.
STEP 1: Convert Input(s) to Base Unit
Inlet Capacity: 42 Cubic Meter per Second --> 42 Cubic Meter per Second No Conversion Required
Acceleration due to Gravity: 9.8 Meter per Square Second --> 9.8 Meter per Square Second No Conversion Required
Depth: 3 Meter --> 3 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
A = Qi/(0.6*(2*g*D)^(1/2)) --> 42/(0.6*(2*9.8*3)^(1/2))
Evaluating ... ...
A = 9.12870929175277
STEP 3: Convert Result to Output's Unit
9.12870929175277 Square Meter --> No Conversion Required
FINAL ANSWER
9.12870929175277 9.128709 Square Meter <-- Area
(Calculation completed in 00.020 seconds)

Credits

Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

10+ Disposing of storm water Calculators

Depth of Flow at Inlet when Runoff Quantity with Full Gutter Flow is Giiven
Go Depth of flow at Inlet = ((Quantity of Runoff/(0.7*Length of Opening))^(2/3))-Depression in Curb Inlet
Depression in Curb Inlet given Runoff Quantity with Full Gutter flow
Go Depression in Curb Inlet = ((Quantity of Runoff/(0.7*Length of Opening))^(2/3))-Depth of flow at Inlet
Length of Opening given Runoff Quantity with Full Gutter Flow
Go Length of Opening = Quantity of Runoff/(0.7*(Depression in Curb Inlet+Depth of flow at Inlet)^(3/2))
Runoff Quantity with Full Gutter Flow
Go Quantity of Runoff = 0.7*Length of Opening*(Depression in Curb Inlet+Depth of flow at Inlet)^(3/2)
Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in
Go Depth = ((Inlet Capacity/(0.6*Area))^2)*(1/(2*Acceleration due to Gravity))
Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in
Go Area = Inlet Capacity/(0.6*(2*Acceleration due to Gravity*Depth)^(1/2))
Inlet Capacity for Flow Depth more than 1ft 5in
Go Inlet Capacity = 0.6*Area*((2*Acceleration due to Gravity*Depth)^(1/2))
Depth of Flow at Inlet given Inlet Capacity for Flow Depth up to 4.8in
Go Depth of flow at Inlet = (Water Flow/(3*Perimeter of grate opening))^(2/3)
Perimeter when Inlet Capacity for Flow Depth is up to 4.8 inches
Go Perimeter of grate opening = Water Flow/(3*Depth of flow at Inlet^(3/2))
Inlet Capacity for Flow Depth
Go Water Flow = 3*Perimeter of grate opening*Depth of flow at Inlet^(3/2)

Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in Formula

Area = Inlet Capacity/(0.6*(2*Acceleration due to Gravity*Depth)^(1/2))
A = Qi/(0.6*(2*g*D)^(1/2))

What is flow depth?

Flow depth is the depth of flow in a channel or culvert when the slope of the water surface and channel bottom is the same and the water depth remains constant.

How to Calculate Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in?

Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in calculator uses Area = Inlet Capacity/(0.6*(2*Acceleration due to Gravity*Depth)^(1/2)) to calculate the Area, Area of opening given inlet capacity for flow depth more than 1ft 5in formula is defined as is area of opening of sewer pipe from where waster is discharged. Area is denoted by A symbol.

How to calculate Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in using this online calculator? To use this online calculator for Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in, enter Inlet Capacity (Qi), Acceleration due to Gravity (g) & Depth (D) and hit the calculate button. Here is how the Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in calculation can be explained with given input values -> 9.128709 = 42/(0.6*(2*9.8*3)^(1/2)).

FAQ

What is Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in?
Area of opening given inlet capacity for flow depth more than 1ft 5in formula is defined as is area of opening of sewer pipe from where waster is discharged and is represented as A = Qi/(0.6*(2*g*D)^(1/2)) or Area = Inlet Capacity/(0.6*(2*Acceleration due to Gravity*Depth)^(1/2)). Inlet Capacity measures the flow in a sewer in terms of cubic meters of flow per day, Acceleration due to Gravity is acceleration gained by an object because of gravitational force & Depth is the distance from the top or surface to the bottom of something.
How to calculate Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in?
Area of opening given inlet capacity for flow depth more than 1ft 5in formula is defined as is area of opening of sewer pipe from where waster is discharged is calculated using Area = Inlet Capacity/(0.6*(2*Acceleration due to Gravity*Depth)^(1/2)). To calculate Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in, you need Inlet Capacity (Qi), Acceleration due to Gravity (g) & Depth (D). With our tool, you need to enter the respective value for Inlet Capacity, Acceleration due to Gravity & Depth and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!