Average Load Current of Three Phase Semi-Current Solution

STEP 0: Pre-Calculation Summary
Formula Used
Load Current 3 Phase Semi Converter = Average Voltage 3 Phase Semi Converter/Resistance 3 Phase Semi Converter
IL(3Φ-semi) = Vavg(3Φ-semi)/R3Φ-semi
This formula uses 3 Variables
Variables Used
Load Current 3 Phase Semi Converter - (Measured in Ampere) - Load Current 3 Phase Semi Converter is defined as the current flowing through the load terminal of a semi converter circuit.
Average Voltage 3 Phase Semi Converter - (Measured in Volt) - Average Voltage 3 Phase Semi Converter is defined as the average of voltage over one complete cycle in a semi converter circuit.
Resistance 3 Phase Semi Converter - (Measured in Ohm) - Resistance 3 Phase Semi Converter is a measure of the opposition to current flow in an electrical circuit. Its S.I unit is ohm.
STEP 1: Convert Input(s) to Base Unit
Average Voltage 3 Phase Semi Converter: 25.21 Volt --> 25.21 Volt No Conversion Required
Resistance 3 Phase Semi Converter: 29 Ohm --> 29 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
IL(3Φ-semi) = Vavg(3Φ-semi)/R3Φ-semi --> 25.21/29
Evaluating ... ...
IL(3Φ-semi) = 0.869310344827586
STEP 3: Convert Result to Output's Unit
0.869310344827586 Ampere --> No Conversion Required
FINAL ANSWER
0.869310344827586 0.86931 Ampere <-- Load Current 3 Phase Semi Converter
(Calculation completed in 00.004 seconds)

Credits

Created by Devyaani Garg
Shiv Nadar University (SNU), Greater Noida
Devyaani Garg has created this Calculator and 50+ more calculators!
Verified by Nikita Suryawanshi
Vellore Institute of Technology (VIT), Vellore
Nikita Suryawanshi has verified this Calculator and 25+ more calculators!

4 Three Phase Semi-Converter Calculators

RMS Output Voltage for Three Phase Semi-Converter
Go RMS Output Voltage 3 Phase Semi Converter = sqrt(3)*Peak Input Voltage 3 Phase Semi Converter*((3/(4*pi))*(pi-Delay Angle of 3 Phase Semi Converter+((sin(2*Delay Angle of 3 Phase Semi Converter))/2))^0.5)
Average Output Voltage for Three Phase Semi-Converter
Go Average Voltage 3 Phase Semi Converter = (2.6*Peak Input Voltage 3 Phase Semi Converter*(1+cos(Delay Angle of 3 Phase Semi Converter)))/pi
Average Load Current of Three Phase Semi-Current
Go Load Current 3 Phase Semi Converter = Average Voltage 3 Phase Semi Converter/Resistance 3 Phase Semi Converter
Normalized Average Output Voltage
Go Normalized Output Voltage 3 Phase Semi Converter = 0.5*(1+cos(Delay Angle of 3 Phase Semi Converter))

19 Power Converter Characteristics Calculators

RMS Harmonic Current for PWM Control
Go RMS nth Harmonic Current = ((sqrt(2)*Armature Current)/pi)*sum(x,1,Number of Pulse in Half-cycle of PWM,(cos(Harmonic Order*Excitation Angle))-(cos(Harmonic Order*Symmetrical Angle)))
Average Output Voltage for PWM Control
Go Average Output Voltage of PWM Controlled Converter = (Peak Input Voltage of PWM Converter/pi)*sum(x,1,Number of Pulse in Half-cycle of PWM,(cos(Excitation Angle)-cos(Symmetrical Angle)))
Fundamental Supply Current for PWM Control
Go Fundamental Supply Current = ((sqrt(2)*Armature Current)/pi)*sum(x,1,Number of Pulse in Half-cycle of PWM,(cos(Excitation Angle))-(cos(Symmetrical Angle)))
RMS Output Voltage for Three Phase Semi-Converter
Go RMS Output Voltage 3 Phase Semi Converter = sqrt(3)*Peak Input Voltage 3 Phase Semi Converter*((3/(4*pi))*(pi-Delay Angle of 3 Phase Semi Converter+((sin(2*Delay Angle of 3 Phase Semi Converter))/2))^0.5)
RMS Supply Current for PWM Control
Go Root Mean Square Current = Armature Current/sqrt(pi)*sqrt(sum(x,1,Number of Pulse in Half-cycle of PWM,(Symmetrical Angle-Excitation Angle)))
RMS Output Voltage for Resistive Load
Go RMS Output Voltage 3 Phase Half Converter = sqrt(3)*Peak Phase Voltage*(sqrt((1/6)+((sqrt(3)*cos(2*Delay Angle of 3 Phase Half Converter))/(8*pi))))
RMS Output Voltage for Continuous Load Current
Go RMS Output Voltage 3 Phase Half Converter = sqrt(3)*Peak Input Voltage 3 Phase Half Converter*((1/6)+(sqrt(3)*cos(2*Delay Angle of 3 Phase Half Converter))/(8*pi))^0.5
RMS Output Voltage of Single Phase Thyristor Converter with Resistive Load
Go RMS Voltage Thyristor Converter = (Peak Input Voltage Thyristor Converter/2)*((180-Delay Angle of Thyristor Converter)/180+(0.5/pi)*sin(2*Delay Angle of Thyristor Converter))^0.5
RMS Output Voltage of Single Phase Semi-Converter with Highly Inductive Load
Go RMS Output Voltage Semi Converter = (Maximum Input Voltage Semi Converter/(2^0.5))*((180-Delay Angle Semi Converter)/180+(0.5/pi)*sin(2*Delay Angle Semi Converter))^0.5
Average Output Voltage for Continuous Load Current
Go Average Voltage 3 Phase Half Converter = (3*sqrt(3)*Peak Input Voltage 3 Phase Half Converter*(cos(Delay Angle of 3 Phase Half Converter)))/(2*pi)
RMS Output Voltage of Three-Phase Full Converter
Go RMS Output Voltage 3 Phase Full Converter = ((6)^0.5)*Peak Input Voltage 3 Phase Full Converter*((0.25+0.65*(cos(2*Delay Angle of 3 Phase Full Converter))/pi)^0.5)
Average Output Voltage of Single Phase Thyristor Converter with Resistive Load
Go Average Voltage Thyristor Converter = (Peak Input Voltage Thyristor Converter/(2*pi))*(1+cos(Delay Angle of Thyristor Converter))
Average Output Voltage for Three-Phase Converter
Go Average Voltage 3 Phase Full Converter = (2*Peak Phase Voltage Full Converter*cos(Delay Angle of 3 Phase Full Converter/2))/pi
DC Output Voltage of Second Converter
Go DC Output Voltage Second Converter = (2*Peak Input Voltage Dual Converter*(cos(Delay Angle of Second Converter)))/pi
DC Output Voltage for First Converter
Go DC Output Voltage First Converter = (2*Peak Input Voltage Dual Converter*(cos(Delay Angle of First Converter)))/pi
Average DC Output Voltage of Single Phase Full Converter
Go Average Voltage Full Converter = (2*Maximum DC Output Voltage Full Converter*cos(Firing Angle Full Converter))/pi
Average Output Voltage of Single Phase Semi-Converter with Highly Inductive Load
Go Average Voltage Semi Converter = (Maximum Input Voltage Semi Converter/pi)*(1+cos(Delay Angle Semi Converter))
Average Load Current of Three Phase Semi-Current
Go Load Current 3 Phase Semi Converter = Average Voltage 3 Phase Semi Converter/Resistance 3 Phase Semi Converter
RMS Output Voltage of Single Phase Full Converter
Go RMS Output Voltage Full Converter = Maximum Input Voltage Full Converter/(sqrt(2))

Average Load Current of Three Phase Semi-Current Formula

Load Current 3 Phase Semi Converter = Average Voltage 3 Phase Semi Converter/Resistance 3 Phase Semi Converter
IL(3Φ-semi) = Vavg(3Φ-semi)/R3Φ-semi

What is the average current?

Average current refers to the average of every instantaneous current value from zero to the peak and back again on a sine wave; alternating or AC is represented by a sine wave.

How to Calculate Average Load Current of Three Phase Semi-Current?

Average Load Current of Three Phase Semi-Current calculator uses Load Current 3 Phase Semi Converter = Average Voltage 3 Phase Semi Converter/Resistance 3 Phase Semi Converter to calculate the Load Current 3 Phase Semi Converter, Average Load Current of Three Phase Semi-Current is calculated by finding the ratio of the average output voltage to the load resistance. Load Current 3 Phase Semi Converter is denoted by IL(3Φ-semi) symbol.

How to calculate Average Load Current of Three Phase Semi-Current using this online calculator? To use this online calculator for Average Load Current of Three Phase Semi-Current, enter Average Voltage 3 Phase Semi Converter (Vavg(3Φ-semi)) & Resistance 3 Phase Semi Converter (R3Φ-semi) and hit the calculate button. Here is how the Average Load Current of Three Phase Semi-Current calculation can be explained with given input values -> 0.86931 = 25.21/29.

FAQ

What is Average Load Current of Three Phase Semi-Current?
Average Load Current of Three Phase Semi-Current is calculated by finding the ratio of the average output voltage to the load resistance and is represented as IL(3Φ-semi) = Vavg(3Φ-semi)/R3Φ-semi or Load Current 3 Phase Semi Converter = Average Voltage 3 Phase Semi Converter/Resistance 3 Phase Semi Converter. Average Voltage 3 Phase Semi Converter is defined as the average of voltage over one complete cycle in a semi converter circuit & Resistance 3 Phase Semi Converter is a measure of the opposition to current flow in an electrical circuit. Its S.I unit is ohm.
How to calculate Average Load Current of Three Phase Semi-Current?
Average Load Current of Three Phase Semi-Current is calculated by finding the ratio of the average output voltage to the load resistance is calculated using Load Current 3 Phase Semi Converter = Average Voltage 3 Phase Semi Converter/Resistance 3 Phase Semi Converter. To calculate Average Load Current of Three Phase Semi-Current, you need Average Voltage 3 Phase Semi Converter (Vavg(3Φ-semi)) & Resistance 3 Phase Semi Converter (R3Φ-semi). With our tool, you need to enter the respective value for Average Voltage 3 Phase Semi Converter & Resistance 3 Phase Semi Converter and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!