Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Line Voltage Terms Solution

STEP 0: Pre-Calculation Summary
Formula Used
Average Output Voltage = (3/(2*pi))*Peak Line Voltage
Vdc = (3/(2*pi))*Vm(line)
This formula uses 1 Constants, 2 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Variables Used
Average Output Voltage - (Measured in Volt) - Average Output Voltage is the average dc value of the output voltage.
Peak Line Voltage - (Measured in Volt) - Peak line voltage is the maximum amplitude of the line voltage of a 3 phase system.
STEP 1: Convert Input(s) to Base Unit
Peak Line Voltage: 239.22 Volt --> 239.22 Volt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vdc = (3/(2*pi))*Vm(line) --> (3/(2*pi))*239.22
Evaluating ... ...
Vdc = 114.21913645933
STEP 3: Convert Result to Output's Unit
114.21913645933 Volt --> No Conversion Required
FINAL ANSWER
114.21913645933 114.2191 Volt <-- Average Output Voltage
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Parminder Singh
Chandigarh University (CU), Punjab
Parminder Singh has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Rachita C
BMS College Of Engineering (BMSCE), Banglore
Rachita C has verified this Calculator and 50+ more calculators!

6 Half Wave Calculators

Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Phase Voltage Terms
​ Go Average Output Voltage = ((3*sqrt(3))/(2*pi))*Peak Phase Voltage
Average Output Power of Three Phase Half Wave Diode Rectifier with R Load
​ Go Average Output Power = 0.684*Peak Phase Voltage*Peak Phase Current
Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Line Voltage Terms
​ Go Average Output Voltage = (3/(2*pi))*Peak Line Voltage
RMS Output Current of Three Phase Half Wave Diode Rectifier with R Load
​ Go Root Mean Square Current = 0.4854*Peak Phase Current
RMS Output Voltage of Three Phase Half Wave Diode Rectifier with Resistive Load
​ Go RMS Output Voltage = 0.84068*Peak Phase Voltage
Ripple Voltage of Three Phase Half Wave Diode Rectifier
​ Go Ripple Voltage = 0.151*Peak Phase Voltage

Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Line Voltage Terms Formula

Average Output Voltage = (3/(2*pi))*Peak Line Voltage
Vdc = (3/(2*pi))*Vm(line)

3 phase half wave rectifier

A 3 Phase rectifier is a device which rectifies the input AC voltage with the use of 3 phase transformer and 3 diodes which are connected to each of the three phases of transformer secondary winding. The three phases of secondary are connected in the form of star thus it is also called Star Connected Secondary. Each diodes conducts for one third of the AC cycle and remaining two diodes will remains open circuit. The output DC voltage will be between the peak value of supply voltage and half of the supply voltage.

How to Calculate Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Line Voltage Terms?

Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Line Voltage Terms calculator uses Average Output Voltage = (3/(2*pi))*Peak Line Voltage to calculate the Average Output Voltage, The Average output voltage of three phase half wave diode rectifier with R load in line voltage terms formula is defined as the average of line voltage on the load side of a rectifier over a complete cycle when the load is resistive in nature. Average Output Voltage is denoted by Vdc symbol.

How to calculate Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Line Voltage Terms using this online calculator? To use this online calculator for Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Line Voltage Terms, enter Peak Line Voltage (Vm(line)) and hit the calculate button. Here is how the Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Line Voltage Terms calculation can be explained with given input values -> 11.69789 = (3/(2*pi))*239.22.

FAQ

What is Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Line Voltage Terms?
The Average output voltage of three phase half wave diode rectifier with R load in line voltage terms formula is defined as the average of line voltage on the load side of a rectifier over a complete cycle when the load is resistive in nature and is represented as Vdc = (3/(2*pi))*Vm(line) or Average Output Voltage = (3/(2*pi))*Peak Line Voltage. Peak line voltage is the maximum amplitude of the line voltage of a 3 phase system.
How to calculate Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Line Voltage Terms?
The Average output voltage of three phase half wave diode rectifier with R load in line voltage terms formula is defined as the average of line voltage on the load side of a rectifier over a complete cycle when the load is resistive in nature is calculated using Average Output Voltage = (3/(2*pi))*Peak Line Voltage. To calculate Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Line Voltage Terms, you need Peak Line Voltage (Vm(line)). With our tool, you need to enter the respective value for Peak Line Voltage and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Average Output Voltage?
In this formula, Average Output Voltage uses Peak Line Voltage. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Average Output Voltage = ((3*sqrt(3))/(2*pi))*Peak Phase Voltage