Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Phase Voltage Terms Solution

STEP 0: Pre-Calculation Summary
Formula Used
Average Output Voltage = ((3*sqrt(3))/(2*pi))*Peak Phase Voltage
Vdc = ((3*sqrt(3))/(2*pi))*Vm(phase)
This formula uses 1 Constants, 1 Functions, 2 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Average Output Voltage - (Measured in Volt) - Average Output Voltage is the average dc value of the output voltage.
Peak Phase Voltage - (Measured in Volt) - Peak Phase Voltage is the maximum amplitude of the phase voltage of a 3 phase system.
STEP 1: Convert Input(s) to Base Unit
Peak Phase Voltage: 115.1 Volt --> 115.1 Volt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vdc = ((3*sqrt(3))/(2*pi))*Vm(phase) --> ((3*sqrt(3))/(2*pi))*115.1
Evaluating ... ...
Vdc = 95.1869337945724
STEP 3: Convert Result to Output's Unit
95.1869337945724 Volt --> No Conversion Required
FINAL ANSWER
95.1869337945724 95.18693 Volt <-- Average Output Voltage
(Calculation completed in 00.004 seconds)

Credits

Created by Parminder Singh
Chandigarh University (CU), Punjab
Parminder Singh has created this Calculator and 100+ more calculators!
Verified by Vidyashree V
BMS College of Engineering (BMSCE), Bangalore
Vidyashree V has verified this Calculator and 25+ more calculators!

6 Half Wave Calculators

Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Phase Voltage Terms
Go Average Output Voltage = ((3*sqrt(3))/(2*pi))*Peak Phase Voltage
Average Output Power of Three Phase Half Wave Diode Rectifier with R Load
Go Average Output Power = 0.684*Peak Phase Voltage*Peak Phase Current
Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Line Voltage Terms
Go Average Output Voltage = (3/(2*pi))*Peak Line Voltage
RMS Output Current of Three Phase Half Wave Diode Rectifier with R Load
Go Root Mean Square Current = 0.4854*Peak Phase Current
RMS Output Voltage of Three Phase Half Wave Diode Rectifier with Resistive Load
Go RMS Output Voltage = 0.84068*Peak Phase Voltage
Ripple Voltage of Three Phase Half Wave Diode Rectifier
Go Ripple Voltage = 0.151*Peak Phase Voltage

Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Phase Voltage Terms Formula

Average Output Voltage = ((3*sqrt(3))/(2*pi))*Peak Phase Voltage
Vdc = ((3*sqrt(3))/(2*pi))*Vm(phase)

What is a 3 phase half wave rectifier?

A 3 Phase rectifier is a device which rectifies the input AC voltage with the use of 3 phase transformer and 3 diodes which are connected to each of the three phases of transformer secondary winding. The three phases of secondary are connected in the form of star thus it is also called Star Connected Secondary. Each diodes conducts for one third of the AC cycle and remaining two diodes will remains open circuit. The ouput DC voltage will be between the peak value of supply voltage and half of the supply voltage.

How to Calculate Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Phase Voltage Terms?

Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Phase Voltage Terms calculator uses Average Output Voltage = ((3*sqrt(3))/(2*pi))*Peak Phase Voltage to calculate the Average Output Voltage, The Average output voltage of three phase half wave diode rectifier with R load in phase voltage terms formula is defined as the average of phase voltage on the load side of a rectifier over a complete cycle when the load is resistive in nature. Average Output Voltage is denoted by Vdc symbol.

How to calculate Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Phase Voltage Terms using this online calculator? To use this online calculator for Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Phase Voltage Terms, enter Peak Phase Voltage (Vm(phase)) and hit the calculate button. Here is how the Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Phase Voltage Terms calculation can be explained with given input values -> 95.18693 = ((3*sqrt(3))/(2*pi))*115.1.

FAQ

What is Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Phase Voltage Terms?
The Average output voltage of three phase half wave diode rectifier with R load in phase voltage terms formula is defined as the average of phase voltage on the load side of a rectifier over a complete cycle when the load is resistive in nature and is represented as Vdc = ((3*sqrt(3))/(2*pi))*Vm(phase) or Average Output Voltage = ((3*sqrt(3))/(2*pi))*Peak Phase Voltage. Peak Phase Voltage is the maximum amplitude of the phase voltage of a 3 phase system.
How to calculate Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Phase Voltage Terms?
The Average output voltage of three phase half wave diode rectifier with R load in phase voltage terms formula is defined as the average of phase voltage on the load side of a rectifier over a complete cycle when the load is resistive in nature is calculated using Average Output Voltage = ((3*sqrt(3))/(2*pi))*Peak Phase Voltage. To calculate Average Output Voltage of Three Phase Half Wave Diode Rectifier with R Load in Phase Voltage Terms, you need Peak Phase Voltage (Vm(phase)). With our tool, you need to enter the respective value for Peak Phase Voltage and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Average Output Voltage?
In this formula, Average Output Voltage uses Peak Phase Voltage. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Average Output Voltage = (3/(2*pi))*Peak Line Voltage
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!