BOD in Sewage Solution

STEP 0: Pre-Calculation Summary
Formula Used
BOD = DO Consumed*(Volume of Diluted Sample/Volume of Undiluted Sample)
BOD = DO*(V/Vu)
This formula uses 4 Variables
Variables Used
BOD - (Measured in Kilogram per Cubic Meter) - BOD Biochemical Oxygen Demand is a measure of the amount of oxygen that microorganisms will consume while decomposing organic matter under aerobic conditions.
DO Consumed - (Measured in Kilogram per Cubic Meter) - DO Consumed refers to the total amount of dissolved oxygen consumed.
Volume of Diluted Sample - (Measured in Cubic Meter) - Volume of Diluted Sample refers to the total space occupied by the diluted sample.
Volume of Undiluted Sample - (Measured in Cubic Meter) - Volume of Undiluted Sample refers to the total space occupied by the undiluted sample.
STEP 1: Convert Input(s) to Base Unit
DO Consumed: 12.5 Milligram per Liter --> 0.0125 Kilogram per Cubic Meter (Check conversion ​here)
Volume of Diluted Sample: 3.5 Cubic Meter --> 3.5 Cubic Meter No Conversion Required
Volume of Undiluted Sample: 2.1 Cubic Meter --> 2.1 Cubic Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
BOD = DO*(V/Vu) --> 0.0125*(3.5/2.1)
Evaluating ... ...
BOD = 0.0208333333333333
STEP 3: Convert Result to Output's Unit
0.0208333333333333 Kilogram per Cubic Meter -->20.8333333333333 Milligram per Liter (Check conversion ​here)
FINAL ANSWER
20.8333333333333 20.83333 Milligram per Liter <-- BOD
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 500+ more calculators!

Biodegradable Oxygen Demand BOD Calculators

BOD in Sewage
​ Go BOD = DO Consumed*(Volume of Diluted Sample/Volume of Undiluted Sample)
BOD of Industry given Population Equivalent
​ Go BOD of Industrial Sewage = 0.08*Population Equivalent
BOD given Dilution Factor
​ Go BOD = DO Consumed*(3/4)

BOD in Sewage Formula

BOD = DO Consumed*(Volume of Diluted Sample/Volume of Undiluted Sample)
BOD = DO*(V/Vu)

What is the Maximum Permissible Limits of BOD?

Maximum Permissible Limits of BOD are set to ensure water quality and protect aquatic life. These limits can vary based on the intended use of the water (e.g., drinking water, recreational water, discharge into natural water bodies) and local regulations.

How to Calculate BOD in Sewage?

BOD in Sewage calculator uses BOD = DO Consumed*(Volume of Diluted Sample/Volume of Undiluted Sample) to calculate the BOD, The BOD in sewage formula is defined as the measure of the amount of oxygen required to remove waste organic matter from water in the process of decomposition by aerobic bacteria. BOD is denoted by BOD symbol.

How to calculate BOD in Sewage using this online calculator? To use this online calculator for BOD in Sewage, enter DO Consumed (DO), Volume of Diluted Sample (V) & Volume of Undiluted Sample (Vu) and hit the calculate button. Here is how the BOD in Sewage calculation can be explained with given input values -> 19886.36 = 0.0125*(3.5/2.1).

FAQ

What is BOD in Sewage?
The BOD in sewage formula is defined as the measure of the amount of oxygen required to remove waste organic matter from water in the process of decomposition by aerobic bacteria and is represented as BOD = DO*(V/Vu) or BOD = DO Consumed*(Volume of Diluted Sample/Volume of Undiluted Sample). DO Consumed refers to the total amount of dissolved oxygen consumed, Volume of Diluted Sample refers to the total space occupied by the diluted sample & Volume of Undiluted Sample refers to the total space occupied by the undiluted sample.
How to calculate BOD in Sewage?
The BOD in sewage formula is defined as the measure of the amount of oxygen required to remove waste organic matter from water in the process of decomposition by aerobic bacteria is calculated using BOD = DO Consumed*(Volume of Diluted Sample/Volume of Undiluted Sample). To calculate BOD in Sewage, you need DO Consumed (DO), Volume of Diluted Sample (V) & Volume of Undiluted Sample (Vu). With our tool, you need to enter the respective value for DO Consumed, Volume of Diluted Sample & Volume of Undiluted Sample and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate BOD?
In this formula, BOD uses DO Consumed, Volume of Diluted Sample & Volume of Undiluted Sample. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • BOD = DO Consumed*(3/4)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!