BOD Influent given MLSS Solution

STEP 0: Pre-Calculation Summary
Formula Used
Influent BOD = (Daily bod*MLSS*Volume of Tank)/(Total Microbial Mass*Sewage Flow)
Qi = (BOD*X*V)/(Mt*Q)
This formula uses 6 Variables
Variables Used
Influent BOD - (Measured in Kilogram per Cubic Meter) - Influent BOD is the total amount of BOD which is present in the incoming sewage.
Daily bod - (Measured in Kilogram) - Daily bod load applied to the aeration system.
MLSS - (Measured in Kilogram per Cubic Meter) - MLSS is the sum of volatile suspended solids (organics) and fixed suspended solids (inorganics).
Volume of Tank - (Measured in Cubic Meter) - Volume of tank is defined as the capacity of flocculation and mixing tank.
Total Microbial Mass - (Measured in Kilogram) - Total microbial mass in the system in grams.
Sewage Flow - (Measured in Cubic Meter) - Sewage flow into the aeration tank is the sewage flow into the aeration tank when we have prior information of other parameters used.
STEP 1: Convert Input(s) to Base Unit
Daily bod: 3 Milligram --> 3E-06 Kilogram (Check conversion ​here)
MLSS: 1200 Milligram per Liter --> 1.2 Kilogram per Cubic Meter (Check conversion ​here)
Volume of Tank: 9 Cubic Meter --> 9 Cubic Meter No Conversion Required
Total Microbial Mass: 3 Gram --> 0.003 Kilogram (Check conversion ​here)
Sewage Flow: 20 Cubic Meter --> 20 Cubic Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Qi = (BOD*X*V)/(Mt*Q) --> (3E-06*1.2*9)/(0.003*20)
Evaluating ... ...
Qi = 0.00054
STEP 3: Convert Result to Output's Unit
0.00054 Kilogram per Cubic Meter -->0.54 Milligram per Liter (Check conversion ​here)
FINAL ANSWER
0.54 Milligram per Liter <-- Influent BOD
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

20 Food to Microorganism Ratio or F/M Ratio Calculators

Microbial Mass in Aeration System given MLSS
​ Go Total Microbial Mass = Daily bod/((Sewage Flow*Influent BOD)/(Volume of Tank*MLSS))
BOD Load Applied given MLSS
​ Go Daily bod = Total Microbial Mass*((Sewage Flow*Influent BOD)/(Volume of Tank*MLSS))
MLSS given BOD Load Applied to Aeration System
​ Go MLSS = (Total Microbial Mass*Sewage Flow*Influent BOD)/(Volume of Tank*Daily bod)
Volume of Tank given MLSS
​ Go Volume of Tank = (Total Microbial Mass*Sewage Flow*Influent BOD)/(MLSS*Daily bod)
BOD Influent given MLSS
​ Go Influent BOD = (Daily bod*MLSS*Volume of Tank)/(Total Microbial Mass*Sewage Flow)
Sewage Flow given MLSS
​ Go Sewage Flow = (Daily bod*MLSS*Volume of Tank)/(Total Microbial Mass*Influent BOD)
Biological Oxygen Demand influent
​ Go Biological oxygen demand = (Food to microorganism ratio*Volume of Tank*MLSS)/Sewage Flow
Volume of Tank given Food to Microorganism Ratio
​ Go Volume of Tank = (Sewage Flow*Influent BOD)/(Food to microorganism ratio*MLSS)
Food to Microorganism Ratio given MLSS
​ Go Food to microorganism ratio = (Sewage Flow*Influent BOD)/(MLSS*Volume of Tank)
Mixed Liquor Suspended Solid
​ Go MLSS = (Sewage Flow*Influent BOD)/(Food to microorganism ratio*Volume of Tank)
Sewage Flow given Food to Microorganism Ratio
​ Go Sewage Flow = (Food to microorganism ratio*Volume of Tank*MLSS)/Influent BOD
Total Microbial Mass given Food to Microorganism Ratio
​ Go Total Microbial Mass = Daily bod/Food to microorganism ratio
Daily BOD Load given Food to Microorganism Ratio
​ Go Daily bod = Food to microorganism ratio*Total Microbial Mass
Food to Microorganism Ratio
​ Go Food to microorganism ratio = Daily bod/Total Microbial Mass
MLSS given Microbial Mass in Aeration System
​ Go MLSS = (Total Microbial Mass/Volume of Tank)
Volume of Tank given Microbial Mass in Aeration System
​ Go Volume of Tank = Total Microbial Mass/MLSS
Microbial Mass in Aeration System
​ Go Total Microbial Mass = MLSS*Volume of Tank
Sewage Flow into Aeration System given BOD Load applied
​ Go Sewage Flow = Daily bod/Influent BOD
BOD of Influent Sewage given BOD Load applied
​ Go Influent BOD = Daily bod/Sewage Flow
BOD Load applied to Aeration System
​ Go Daily bod = Sewage Flow*Influent BOD

BOD Influent given MLSS Formula

Influent BOD = (Daily bod*MLSS*Volume of Tank)/(Total Microbial Mass*Sewage Flow)
Qi = (BOD*X*V)/(Mt*Q)

What is BOD ?

Biochemical oxygen demand is the amount of dissolved oxygen needed by aerobic biological organisms to break down organic material present in a given water sample at certain temperature over a specific time period.

How to Calculate BOD Influent given MLSS?

BOD Influent given MLSS calculator uses Influent BOD = (Daily bod*MLSS*Volume of Tank)/(Total Microbial Mass*Sewage Flow) to calculate the Influent BOD, BOD Influent given MLSS is amount of dissolved oxygen needed by aerobic biological organisms to break down organic material. Influent BOD is denoted by Qi symbol.

How to calculate BOD Influent given MLSS using this online calculator? To use this online calculator for BOD Influent given MLSS, enter Daily bod (BOD), MLSS (X), Volume of Tank (V), Total Microbial Mass (Mt) & Sewage Flow (Q) and hit the calculate button. Here is how the BOD Influent given MLSS calculation can be explained with given input values -> 540 = (3E-06*1.2*9)/(0.003*20).

FAQ

What is BOD Influent given MLSS?
BOD Influent given MLSS is amount of dissolved oxygen needed by aerobic biological organisms to break down organic material and is represented as Qi = (BOD*X*V)/(Mt*Q) or Influent BOD = (Daily bod*MLSS*Volume of Tank)/(Total Microbial Mass*Sewage Flow). Daily bod load applied to the aeration system, MLSS is the sum of volatile suspended solids (organics) and fixed suspended solids (inorganics), Volume of tank is defined as the capacity of flocculation and mixing tank, Total microbial mass in the system in grams & Sewage flow into the aeration tank is the sewage flow into the aeration tank when we have prior information of other parameters used.
How to calculate BOD Influent given MLSS?
BOD Influent given MLSS is amount of dissolved oxygen needed by aerobic biological organisms to break down organic material is calculated using Influent BOD = (Daily bod*MLSS*Volume of Tank)/(Total Microbial Mass*Sewage Flow). To calculate BOD Influent given MLSS, you need Daily bod (BOD), MLSS (X), Volume of Tank (V), Total Microbial Mass (Mt) & Sewage Flow (Q). With our tool, you need to enter the respective value for Daily bod, MLSS, Volume of Tank, Total Microbial Mass & Sewage Flow and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Influent BOD?
In this formula, Influent BOD uses Daily bod, MLSS, Volume of Tank, Total Microbial Mass & Sewage Flow. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Influent BOD = Daily bod/Sewage Flow
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!