Mridul Sharma
Indian Institute of Information Technology (IIIT), Bhopal
Mridul Sharma has created this Calculator and 100+ more calculators!
Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has verified this Calculator and 100+ more calculators!

11 Other formulas that you can solve using the same Inputs

Strain Energy due to Torsion in Hollow Shaft
Strain Energy=(Shear Stress^(2))*(Outer diameter^(2)+Inner Diameter^(2))*Volume of Shaft/(4*Shear Modulus*Outer diameter^(2)) GO
Conversion factor when flow velocity is given
conversion factor=((flow velocity*roughness coefficient of conduit surface)/((energy loss^(1/2))*hydraulic radius^(2/3))) GO
Hydraulic radius when flow velocity is given
hydraulic radius=((flow velocity*roughness coefficient of conduit surface)/(conversion factor*energy loss^(1/2)))^(3/2) GO
Roughness coefficient when flow velocity is given
roughness coefficient of conduit surface=(conversion factor*hydraulic radius^(2/3)*energy loss^(1/2))/flow velocity GO
Flow velocity using Manning's formula
flow velocity=(conversion factor*hydraulic radius^(2/3)*energy loss^(1/2))/roughness coefficient of conduit surface GO
Inside diameter when full flow velocity in sewer is given
Inner Diameter=((flow velocity*roughness coefficient of conduit surface)/(0.59*energy loss^(1/2)))^(3/2) GO
Full flow velocity in sewer
flow velocity=(0.59*Inner Diameter^(2/3)*energy loss^(1/2))/roughness coefficient of conduit surface GO
angle of twist for hollow cylindrical rod in degrees
Total Angle of Twist=584*Torque*Length/(Modulus of rigidity*((Outer diameter^4)-(Inner Diameter^4))) GO
Moment of Inertia for Hollow Circular Shaft
Polar moment of Inertia=pi*(Outer diameter^(4)-Inner Diameter^(4))/32 GO
Velocity when water flow equation is given
flow velocity=water flow/Cross sectional area GO
Area when water flow equation is given
Cross sectional area=water flow/flow velocity GO

2 Other formulas that calculate the same Output

Roughness coefficient when flow velocity is given
roughness coefficient of conduit surface=(conversion factor*hydraulic radius^(2/3)*energy loss^(1/2))/flow velocity GO
Coefficient of roughness when full flow velocity in sewer is given
roughness coefficient of conduit surface=(0.59*Inner Diameter^(2/3)*energy loss^(1/2))/flow velocity GO

Coefficient of roughness when flow quantity for a full flowing sewer is given Formula

roughness coefficient of conduit surface=(0.463*energy loss^(1/2)*Inner Diameter^(8/3))/water flow
n=(0.463*S^(1/2)*Di^(8/3))/Q
More formulas
Full flow velocity in sewer GO
Inside diameter when full flow velocity in sewer is given GO
Coefficient of roughness when full flow velocity in sewer is given GO
Energy loss when full flow velocity in sewer is given GO
Flow quantity for a full flowing sewer GO
Inside diameter when flow quantity for a full flowing sewer is given GO
Energy loss when flow quantity for a full flowing sewer is given GO

What is pipe roughness coefficient?

Roughness coefficient is a value used in Manning's formula to determine energy losses of flowing water due to pipe or channel wall roughness.It is based on the material of the pipe. New steel pipe uses a C value of 140, but with use and corrosion a lower value is typically used. For HDPE pipe, a range of C values between 150 and 160 is typical.

How to Calculate Coefficient of roughness when flow quantity for a full flowing sewer is given?

Coefficient of roughness when flow quantity for a full flowing sewer is given calculator uses roughness coefficient of conduit surface=(0.463*energy loss^(1/2)*Inner Diameter^(8/3))/water flow to calculate the roughness coefficient of conduit surface, The Coefficient of roughness when flow quantity for a full flowing sewer is given formula calculates the roughness coefficient when we have a prior info of the flow quantity ,inner diameter of the pipe and energy loss. roughness coefficient of conduit surface and is denoted by n symbol.

How to calculate Coefficient of roughness when flow quantity for a full flowing sewer is given using this online calculator? To use this online calculator for Coefficient of roughness when flow quantity for a full flowing sewer is given, enter energy loss (S), Inner Diameter (Di) and water flow (Q) and hit the calculate button. Here is how the Coefficient of roughness when flow quantity for a full flowing sewer is given calculation can be explained with given input values -> 72889.96 = (0.463*2^(1/2)*50^(8/3))/0.304800000001219.

FAQ

What is Coefficient of roughness when flow quantity for a full flowing sewer is given?
The Coefficient of roughness when flow quantity for a full flowing sewer is given formula calculates the roughness coefficient when we have a prior info of the flow quantity ,inner diameter of the pipe and energy loss and is represented as n=(0.463*S^(1/2)*Di^(8/3))/Q or roughness coefficient of conduit surface=(0.463*energy loss^(1/2)*Inner Diameter^(8/3))/water flow. energy loss is the loss of energy of flowing water, The Inner Diameter is the diameter of inner circle of circular hollow shaft and water flow is rate of flow of water.
How to calculate Coefficient of roughness when flow quantity for a full flowing sewer is given?
The Coefficient of roughness when flow quantity for a full flowing sewer is given formula calculates the roughness coefficient when we have a prior info of the flow quantity ,inner diameter of the pipe and energy loss is calculated using roughness coefficient of conduit surface=(0.463*energy loss^(1/2)*Inner Diameter^(8/3))/water flow. To calculate Coefficient of roughness when flow quantity for a full flowing sewer is given, you need energy loss (S), Inner Diameter (Di) and water flow (Q). With our tool, you need to enter the respective value for energy loss, Inner Diameter and water flow and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate roughness coefficient of conduit surface?
In this formula, roughness coefficient of conduit surface uses energy loss, Inner Diameter and water flow. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • roughness coefficient of conduit surface=(conversion factor*hydraulic radius^(2/3)*energy loss^(1/2))/flow velocity
  • roughness coefficient of conduit surface=(0.59*Inner Diameter^(2/3)*energy loss^(1/2))/flow velocity
Share Image
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!