Mridul Sharma
Indian Institute of Information Technology (IIIT), Bhopal
Mridul Sharma has created this Calculator and 100+ more calculators!
Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 500+ more calculators!

11 Other formulas that you can solve using the same Inputs

Hydraulic radius when flow velocity is given
hydraulic radius=((flow velocity*roughness coefficient of conduit surface)/(conversion factor*energy loss^(1/2)))^(3/2) GO
Roughness coefficient when flow velocity is given
roughness coefficient of conduit surface=(conversion factor*hydraulic radius^(2/3)*energy loss^(1/2))/flow velocity GO
Energy loss when flow velocity is given
energy loss=((flow velocity*roughness coefficient of conduit surface)/(conversion factor*hydraulic radius^(2/3)))^2 GO
Flow velocity using Manning's formula
flow velocity=(conversion factor*hydraulic radius^(2/3)*energy loss^(1/2))/roughness coefficient of conduit surface GO
Inside diameter when full flow velocity in sewer is given
Inner Diameter=((flow velocity*roughness coefficient of conduit surface)/(0.59*energy loss^(1/2)))^(3/2) GO
Coefficient of roughness when full flow velocity in sewer is given
roughness coefficient of conduit surface=(0.59*Inner Diameter^(2/3)*energy loss^(1/2))/flow velocity GO
Energy loss when full flow velocity in sewer is given
energy loss=((flow velocity*roughness coefficient of conduit surface)/(0.59*Inner Diameter^(2/3)))^2 GO
Full flow velocity in sewer
flow velocity=(0.59*Inner Diameter^(2/3)*energy loss^(1/2))/roughness coefficient of conduit surface GO
Flow quantity for a full flowing sewer
water flow=(0.463*energy loss^(1/2)*Inner Diameter^(8/3))/roughness coefficient of conduit surface GO
Area when water flow equation is given
Cross sectional area=water flow/flow velocity GO
Water flow equation
water flow=Cross sectional area*flow velocity GO

Conversion factor when flow velocity is given Formula

conversion factor=((flow velocity*roughness coefficient of conduit surface)/((energy loss^(1/2))*hydraulic radius^(2/3)))
C=((V*n)/((S^(1/2))*R^(2/3)))
More formulas
Flow velocity using Manning's formula GO
Roughness coefficient when flow velocity is given GO
Hydraulic radius when flow velocity is given GO
Energy loss when flow velocity is given GO
Water flow equation GO
Area when water flow equation is given GO
Velocity when water flow equation is given GO

What is hydraulic radius?

hydraulic radius is the ratio of the cross-sectional area of a channel or pipe in which a fluid is flowing to the wet perimeter of the conduit.

How to Calculate Conversion factor when flow velocity is given?

Conversion factor when flow velocity is given calculator uses conversion factor=((flow velocity*roughness coefficient of conduit surface)/((energy loss^(1/2))*hydraulic radius^(2/3))) to calculate the conversion factor, The Conversion factor when flow velocity is given formula calculates the conversion factor to account for change from metric units used in development of the formula when we have a prior info of flow velocity. conversion factor and is denoted by C symbol.

How to calculate Conversion factor when flow velocity is given using this online calculator? To use this online calculator for Conversion factor when flow velocity is given, enter flow velocity (V), roughness coefficient of conduit surface (n), energy loss (S) and hydraulic radius (R) and hit the calculate button. Here is how the Conversion factor when flow velocity is given calculation can be explained with given input values -> 0.983532 = ((1*1)/((2^(1/2))*0.609600000002438^(2/3))).

FAQ

What is Conversion factor when flow velocity is given?
The Conversion factor when flow velocity is given formula calculates the conversion factor to account for change from metric units used in development of the formula when we have a prior info of flow velocity and is represented as C=((V*n)/((S^(1/2))*R^(2/3))) or conversion factor=((flow velocity*roughness coefficient of conduit surface)/((energy loss^(1/2))*hydraulic radius^(2/3))). flow velocity is the velocity of the flow of any fluid, roughness coefficient of conduit surface is coefficient dependent on roughness of conduit surface, energy loss is the loss of energy of flowing water and hydraulic radius is the ratio of the cross-sectional area of a channel or pipe in which a fluid is flowing to the wet perimeter of the conduit.
How to calculate Conversion factor when flow velocity is given?
The Conversion factor when flow velocity is given formula calculates the conversion factor to account for change from metric units used in development of the formula when we have a prior info of flow velocity is calculated using conversion factor=((flow velocity*roughness coefficient of conduit surface)/((energy loss^(1/2))*hydraulic radius^(2/3))). To calculate Conversion factor when flow velocity is given, you need flow velocity (V), roughness coefficient of conduit surface (n), energy loss (S) and hydraulic radius (R). With our tool, you need to enter the respective value for flow velocity, roughness coefficient of conduit surface, energy loss and hydraulic radius and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Share Image
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!