Correction factor for difference between saturation and operation dissolved oxygen Solution

STEP 0: Pre-Calculation Summary
Formula Used
Correction Factor = Oxygen Transferred/((Oxygen transfer capacity*Difference between saturation DO and operation DO *(1.024)^(Temperature-20))/(9.17))
f = N/((Ns*D *(1.024)^(T-20))/(9.17))
This formula uses 5 Variables
Variables Used
Correction Factor - Correction Factor is that which is multiplied with the result of an equation to correct for a known amount of systematic error.
Oxygen Transferred - (Measured in Kilogram per Second per Watt) - Oxygen Transferred under field condition.
Oxygen transfer capacity - (Measured in Kilogram per Second per Watt) - Oxygen transfer capacity under standard conditions.
Difference between saturation DO and operation DO - (Measured in Kilogram per Cubic Meter) - Difference between saturation DO and operation DO is the value obtained after subtracting operation DO from saturation DO.
Temperature - (Measured in Kelvin) - Temperature is the degree or intensity of heat present in a substance or object.
STEP 1: Convert Input(s) to Base Unit
Oxygen Transferred: 3 Kilogram per Hour per Kilowatt --> 8.33333333333333E-07 Kilogram per Second per Watt (Check conversion here)
Oxygen transfer capacity: 2 Kilogram per Hour per Kilowatt --> 5.55555555555556E-07 Kilogram per Second per Watt (Check conversion here)
Difference between saturation DO and operation DO: 3 Milligram per Liter --> 0.003 Kilogram per Cubic Meter (Check conversion here)
Temperature: 85 Kelvin --> 85 Kelvin No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
f = N/((Ns*D *(1.024)^(T-20))/(9.17)) --> 8.33333333333333E-07/((5.55555555555556E-07*0.003 *(1.024)^(85-20))/(9.17))
Evaluating ... ...
f = 981.391197773779
STEP 3: Convert Result to Output's Unit
981.391197773779 --> No Conversion Required
FINAL ANSWER
981.391197773779 981.3912 <-- Correction Factor
(Calculation completed in 00.020 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

4 Operation D.O Level Calculators

Operation Dissolved Oxygen Level
Go Operation dissolved oxygen = Dissolved oxygen saturation-((Oxygen Transferred*9.17)/(Oxygen transfer capacity*Correction Factor*(1.024)^(Temperature-20)))
Correction factor for difference between saturation and operation dissolved oxygen
Go Correction Factor = Oxygen Transferred/((Oxygen transfer capacity*Difference between saturation DO and operation DO *(1.024)^(Temperature-20))/(9.17))
Operation D.O Level when Correction Factor is 0.85
Go Operation dissolved oxygen = Dissolved oxygen saturation-((Oxygen Transferred*9.17)/(Oxygen transfer capacity*0.85*(1.024)^(Temperature-20)))
Operation D.O Level when Correction Factor is 0.8
Go Operation dissolved oxygen = Dissolved oxygen saturation-((Oxygen Transferred*9.17)/(Oxygen transfer capacity*0.8*(1.024)^(Temperature-20)))

Correction factor for difference between saturation and operation dissolved oxygen Formula

Correction Factor = Oxygen Transferred/((Oxygen transfer capacity*Difference between saturation DO and operation DO *(1.024)^(Temperature-20))/(9.17))
f = N/((Ns*D *(1.024)^(T-20))/(9.17))

What is dissolved oxygen ?

Dissolved Oxygen is the amount of gaseous oxygen (O2) dissolved in the water. Oxygen enters the water by direct absorption from the atmosphere, by rapid movement, or as a waste product of plant photosynthesis.

How to Calculate Correction factor for difference between saturation and operation dissolved oxygen?

Correction factor for difference between saturation and operation dissolved oxygen calculator uses Correction Factor = Oxygen Transferred/((Oxygen transfer capacity*Difference between saturation DO and operation DO *(1.024)^(Temperature-20))/(9.17)) to calculate the Correction Factor, The Correction factor for difference between saturation and operation dissolved oxygen calculates the correction factor when we have prior information of other parameters used. Correction Factor is denoted by f symbol.

How to calculate Correction factor for difference between saturation and operation dissolved oxygen using this online calculator? To use this online calculator for Correction factor for difference between saturation and operation dissolved oxygen, enter Oxygen Transferred (N), Oxygen transfer capacity (Ns), Difference between saturation DO and operation DO (D) & Temperature (T) and hit the calculate button. Here is how the Correction factor for difference between saturation and operation dissolved oxygen calculation can be explained with given input values -> 981.3912 = 8.33333333333333E-07/((5.55555555555556E-07*0.003 *(1.024)^(85-20))/(9.17)).

FAQ

What is Correction factor for difference between saturation and operation dissolved oxygen?
The Correction factor for difference between saturation and operation dissolved oxygen calculates the correction factor when we have prior information of other parameters used and is represented as f = N/((Ns*D *(1.024)^(T-20))/(9.17)) or Correction Factor = Oxygen Transferred/((Oxygen transfer capacity*Difference between saturation DO and operation DO *(1.024)^(Temperature-20))/(9.17)). Oxygen Transferred under field condition, Oxygen transfer capacity under standard conditions, Difference between saturation DO and operation DO is the value obtained after subtracting operation DO from saturation DO & Temperature is the degree or intensity of heat present in a substance or object.
How to calculate Correction factor for difference between saturation and operation dissolved oxygen?
The Correction factor for difference between saturation and operation dissolved oxygen calculates the correction factor when we have prior information of other parameters used is calculated using Correction Factor = Oxygen Transferred/((Oxygen transfer capacity*Difference between saturation DO and operation DO *(1.024)^(Temperature-20))/(9.17)). To calculate Correction factor for difference between saturation and operation dissolved oxygen, you need Oxygen Transferred (N), Oxygen transfer capacity (Ns), Difference between saturation DO and operation DO (D) & Temperature (T). With our tool, you need to enter the respective value for Oxygen Transferred, Oxygen transfer capacity, Difference between saturation DO and operation DO & Temperature and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!