Critical Rainfall Intensity for Peak Rate of Runoff Solution

STEP 0: Pre-Calculation Summary
Formula Used
Critical Rainfall Intensity = (36*Peak Drainage Discharge by Rational Formula)/(Area of Catchment*Runoff Coefficient)
Pc = (36*QR)/(Ac*Cr)
This formula uses 4 Variables
Variables Used
Critical Rainfall Intensity - (Measured in Centimeter per Hour) - Critical rainfall intensity is the precipitation rate at which surface runoff initiates, leading to increased risk of flooding or other hydrological hazards.
Peak Drainage Discharge by Rational Formula - (Measured in Cubic Meter per Second) - The peak drainage discharge by Rational Formula estimates stormwater runoff using parameters such as rainfall intensity, catchment area, and runoff coefficient to determine the maximum flow rate.
Area of Catchment - (Measured in Square Meter) - Area of Catchment is an area of land where all water flows to a single stream, river, lake or even ocean.
Runoff Coefficient - Runoff Coefficient is a dimensionless coefficient relating the amount of runoff to the amount of precipitation received.
STEP 1: Convert Input(s) to Base Unit
Peak Drainage Discharge by Rational Formula: 4166.67 Cubic Meter per Second --> 4166.67 Cubic Meter per Second No Conversion Required
Area of Catchment: 15 Hectare --> 150000 Square Meter (Check conversion here)
Runoff Coefficient: 0.5 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Pc = (36*QR)/(Ac*Cr) --> (36*4166.67)/(150000*0.5)
Evaluating ... ...
Pc = 2.0000016
STEP 3: Convert Result to Output's Unit
5.55556E-06 Meter per Second -->2.0000016 Centimeter per Hour (Check conversion here)
FINAL ANSWER
2.0000016 2.000002 Centimeter per Hour <-- Critical Rainfall Intensity
(Calculation completed in 00.004 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

4 Peak Drainage Discharge by Rational Formula Calculators

Catchment Area given Peak Rate of Runoff and Rainfall Intensity
Go Area of Catchment = (36*Peak Drainage Discharge by Rational Formula)/(Runoff Coefficient*Critical Rainfall Intensity)
Critical Rainfall Intensity for Peak Rate of Runoff
Go Critical Rainfall Intensity = (36*Peak Drainage Discharge by Rational Formula)/(Area of Catchment*Runoff Coefficient)
Coefficient of Runoff given Peak Rate of Runoff
Go Runoff Coefficient = (36*Peak Drainage Discharge by Rational Formula)/(Area of Catchment*Critical Rainfall Intensity)
Peak Rate of Runoff in Rational Formula
Go Peak Drainage Discharge by Rational Formula = (Runoff Coefficient*Area of Catchment*Critical Rainfall Intensity)/36

Critical Rainfall Intensity for Peak Rate of Runoff Formula

Critical Rainfall Intensity = (36*Peak Drainage Discharge by Rational Formula)/(Area of Catchment*Runoff Coefficient)
Pc = (36*QR)/(Ac*Cr)

What is Rainfall Intensity ?

Rainfall intensity is defined as the ratio of the total amount of rain (rainfall depth) falling during a given period to the duration of the period It is expressed in depth units per unit time, usually as mm per hour (cm/h).

How to Calculate Critical Rainfall Intensity for Peak Rate of Runoff?

Critical Rainfall Intensity for Peak Rate of Runoff calculator uses Critical Rainfall Intensity = (36*Peak Drainage Discharge by Rational Formula)/(Area of Catchment*Runoff Coefficient) to calculate the Critical Rainfall Intensity, The Critical Rainfall Intensity for Peak Rate of Runoff is defined as the intensity of critical rainfall when we have prior information of other parameters. Critical Rainfall Intensity is denoted by Pc symbol.

How to calculate Critical Rainfall Intensity for Peak Rate of Runoff using this online calculator? To use this online calculator for Critical Rainfall Intensity for Peak Rate of Runoff, enter Peak Drainage Discharge by Rational Formula (QR), Area of Catchment (Ac) & Runoff Coefficient (Cr) and hit the calculate button. Here is how the Critical Rainfall Intensity for Peak Rate of Runoff calculation can be explained with given input values -> 720000.6 = (36*4166.67)/(150000*0.5).

FAQ

What is Critical Rainfall Intensity for Peak Rate of Runoff?
The Critical Rainfall Intensity for Peak Rate of Runoff is defined as the intensity of critical rainfall when we have prior information of other parameters and is represented as Pc = (36*QR)/(Ac*Cr) or Critical Rainfall Intensity = (36*Peak Drainage Discharge by Rational Formula)/(Area of Catchment*Runoff Coefficient). The peak drainage discharge by Rational Formula estimates stormwater runoff using parameters such as rainfall intensity, catchment area, and runoff coefficient to determine the maximum flow rate, Area of Catchment is an area of land where all water flows to a single stream, river, lake or even ocean & Runoff Coefficient is a dimensionless coefficient relating the amount of runoff to the amount of precipitation received.
How to calculate Critical Rainfall Intensity for Peak Rate of Runoff?
The Critical Rainfall Intensity for Peak Rate of Runoff is defined as the intensity of critical rainfall when we have prior information of other parameters is calculated using Critical Rainfall Intensity = (36*Peak Drainage Discharge by Rational Formula)/(Area of Catchment*Runoff Coefficient). To calculate Critical Rainfall Intensity for Peak Rate of Runoff, you need Peak Drainage Discharge by Rational Formula (QR), Area of Catchment (Ac) & Runoff Coefficient (Cr). With our tool, you need to enter the respective value for Peak Drainage Discharge by Rational Formula, Area of Catchment & Runoff Coefficient and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!