How to Calculate D.O Saturation for Sewage when Correction Factor is 0.85?
D.O Saturation for Sewage when Correction Factor is 0.85 calculator uses Dissolved oxygen saturation = ((Oxygen Transferred*9.17)/(Oxygen transfer capacity*0.85*(1.024)^(Temperature-20)))+Operation dissolved oxygen to calculate the Dissolved oxygen saturation, The D.O Saturation for Sewage when Correction Factor is 0.85 calculates the saturated dissolved oxygen when we have prior information of other parameters used. Dissolved oxygen saturation is denoted by DS symbol.
How to calculate D.O Saturation for Sewage when Correction Factor is 0.85 using this online calculator? To use this online calculator for D.O Saturation for Sewage when Correction Factor is 0.85, enter Oxygen Transferred (N), Oxygen transfer capacity (Ns), Temperature (T) & Operation dissolved oxygen (DL) and hit the calculate button. Here is how the D.O Saturation for Sewage when Correction Factor is 0.85 calculation can be explained with given input values -> 3.5E+6 = ((8.33333333333333E-07*9.17)/(5.55555555555556E-07*0.85*(1.024)^(85-20)))+0.002.