D.O Saturation for Sewage when Correction Factor is 0.85 Solution

STEP 0: Pre-Calculation Summary
Formula Used
Dissolved oxygen saturation = ((Oxygen Transferred*9.17)/(Oxygen transfer capacity*0.85*(1.024)^(Temperature-20)))+Operation dissolved oxygen
DS = ((N*9.17)/(Ns*0.85*(1.024)^(T-20)))+DL
This formula uses 5 Variables
Variables Used
Dissolved oxygen saturation - (Measured in Kilogram per Cubic Meter) - Dissolved oxygen saturation value for sewage at operating temperature.
Oxygen Transferred - (Measured in Kilogram per Second per Watt) - Oxygen Transferred under field condition.
Oxygen transfer capacity - (Measured in Kilogram per Second per Watt) - Oxygen transfer capacity under standard conditions.
Temperature - (Measured in Kelvin) - Temperature is the degree or intensity of heat present in a substance or object.
Operation dissolved oxygen - (Measured in Kilogram per Cubic Meter) - Operation dissolved oxygen level in aeration tank.
STEP 1: Convert Input(s) to Base Unit
Oxygen Transferred: 3 Kilogram per Hour per Kilowatt --> 8.33333333333333E-07 Kilogram per Second per Watt (Check conversion here)
Oxygen transfer capacity: 2 Kilogram per Hour per Kilowatt --> 5.55555555555556E-07 Kilogram per Second per Watt (Check conversion here)
Temperature: 85 Kelvin --> 85 Kelvin No Conversion Required
Operation dissolved oxygen: 2 Milligram per Liter --> 0.002 Kilogram per Cubic Meter (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
DS = ((N*9.17)/(Ns*0.85*(1.024)^(T-20)))+DL --> ((8.33333333333333E-07*9.17)/(5.55555555555556E-07*0.85*(1.024)^(85-20)))+0.002
Evaluating ... ...
DS = 3.46573363920157
STEP 3: Convert Result to Output's Unit
3.46573363920157 Kilogram per Cubic Meter -->3465.73363920157 Milligram per Liter (Check conversion here)
FINAL ANSWER
3465.73363920157 3465.734 Milligram per Liter <-- Dissolved oxygen saturation
(Calculation completed in 00.020 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

3 D.O Saturation Calculators

Dissolved Oxygen Saturation for Sewage
Go Dissolved oxygen saturation = ((Oxygen Transferred*9.17)/(Oxygen transfer capacity*Correction Factor*(1.024)^(Temperature-20)))+Operation dissolved oxygen
D.O Saturation for Sewage when Correction Factor is 0.85
Go Dissolved oxygen saturation = ((Oxygen Transferred*9.17)/(Oxygen transfer capacity*0.85*(1.024)^(Temperature-20)))+Operation dissolved oxygen
D.O Saturation for Sewage when Correction Factor is 0.8
Go Dissolved oxygen saturation = ((Oxygen Transferred*9.17)/(Oxygen transfer capacity*0.8*(1.024)^(Temperature-20)))+Operation dissolved oxygen

D.O Saturation for Sewage when Correction Factor is 0.85 Formula

Dissolved oxygen saturation = ((Oxygen Transferred*9.17)/(Oxygen transfer capacity*0.85*(1.024)^(Temperature-20)))+Operation dissolved oxygen
DS = ((N*9.17)/(Ns*0.85*(1.024)^(T-20)))+DL

What is dissolved oxygen ?

Dissolved Oxygen is the amount of gaseous oxygen (O2) dissolved in the water. Oxygen enters the water by direct absorption from the atmosphere, by rapid movement, or as a waste product of plant photosynthesis. Water temperature and the volume of moving water can affect dissolved oxygen levels.

How to Calculate D.O Saturation for Sewage when Correction Factor is 0.85?

D.O Saturation for Sewage when Correction Factor is 0.85 calculator uses Dissolved oxygen saturation = ((Oxygen Transferred*9.17)/(Oxygen transfer capacity*0.85*(1.024)^(Temperature-20)))+Operation dissolved oxygen to calculate the Dissolved oxygen saturation, The D.O Saturation for Sewage when Correction Factor is 0.85 calculates the saturated dissolved oxygen when we have prior information of other parameters used. Dissolved oxygen saturation is denoted by DS symbol.

How to calculate D.O Saturation for Sewage when Correction Factor is 0.85 using this online calculator? To use this online calculator for D.O Saturation for Sewage when Correction Factor is 0.85, enter Oxygen Transferred (N), Oxygen transfer capacity (Ns), Temperature (T) & Operation dissolved oxygen (DL) and hit the calculate button. Here is how the D.O Saturation for Sewage when Correction Factor is 0.85 calculation can be explained with given input values -> 3.5E+6 = ((8.33333333333333E-07*9.17)/(5.55555555555556E-07*0.85*(1.024)^(85-20)))+0.002.

FAQ

What is D.O Saturation for Sewage when Correction Factor is 0.85?
The D.O Saturation for Sewage when Correction Factor is 0.85 calculates the saturated dissolved oxygen when we have prior information of other parameters used and is represented as DS = ((N*9.17)/(Ns*0.85*(1.024)^(T-20)))+DL or Dissolved oxygen saturation = ((Oxygen Transferred*9.17)/(Oxygen transfer capacity*0.85*(1.024)^(Temperature-20)))+Operation dissolved oxygen. Oxygen Transferred under field condition, Oxygen transfer capacity under standard conditions, Temperature is the degree or intensity of heat present in a substance or object & Operation dissolved oxygen level in aeration tank.
How to calculate D.O Saturation for Sewage when Correction Factor is 0.85?
The D.O Saturation for Sewage when Correction Factor is 0.85 calculates the saturated dissolved oxygen when we have prior information of other parameters used is calculated using Dissolved oxygen saturation = ((Oxygen Transferred*9.17)/(Oxygen transfer capacity*0.85*(1.024)^(Temperature-20)))+Operation dissolved oxygen. To calculate D.O Saturation for Sewage when Correction Factor is 0.85, you need Oxygen Transferred (N), Oxygen transfer capacity (Ns), Temperature (T) & Operation dissolved oxygen (DL). With our tool, you need to enter the respective value for Oxygen Transferred, Oxygen transfer capacity, Temperature & Operation dissolved oxygen and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Dissolved oxygen saturation?
In this formula, Dissolved oxygen saturation uses Oxygen Transferred, Oxygen transfer capacity, Temperature & Operation dissolved oxygen. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Dissolved oxygen saturation = ((Oxygen Transferred*9.17)/(Oxygen transfer capacity*Correction Factor*(1.024)^(Temperature-20)))+Operation dissolved oxygen
  • Dissolved oxygen saturation = ((Oxygen Transferred*9.17)/(Oxygen transfer capacity*0.8*(1.024)^(Temperature-20)))+Operation dissolved oxygen
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!