Efficiency of Single Stage High Rate Trickling Filter Solution

STEP 0: Pre-Calculation Summary
Formula Used
Efficiency of First Filter Stage = (100/(1+0.0044*sqrt(Total Organic Load/(Volume*Recirculation Factor))))
E1 = (100/(1+0.0044*sqrt(Y/(VT*F))))
This formula uses 1 Functions, 4 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Efficiency of First Filter Stage - Efficiency of first filter stage calculates the efficiency of the filter at the first stage.
Total Organic Load - (Measured in Kilogram per Second) - Total organic load is the total amount of organic material present in a water or wastewater sample.
Volume - (Measured in Cubic Meter) - Volume is the three-dimensional space occupied by a substance or object, such as water, soil, air, or any environmental medium.
Recirculation Factor - Recirculation factor r represents the average number of passes of the influent organic matter through the trickling filter.
STEP 1: Convert Input(s) to Base Unit
Total Organic Load: 80 Kilogram per Day --> 0.000925925925925926 Kilogram per Second (Check conversion ​here)
Volume: 0.63 Cubic Meter --> 0.63 Cubic Meter No Conversion Required
Recirculation Factor: 1.116 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
E1 = (100/(1+0.0044*sqrt(Y/(VT*F)))) --> (100/(1+0.0044*sqrt(0.000925925925925926/(0.63*1.116))))
Evaluating ... ...
E1 = 99.9840349940019
STEP 3: Convert Result to Output's Unit
99.9840349940019 --> No Conversion Required
FINAL ANSWER
99.9840349940019 99.98403 <-- Efficiency of First Filter Stage
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar LinkedIn Logo
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal LinkedIn Logo
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Efficiency of High Rate Filters Calculators

Recirculation Factor given Volume of Raw Sewage
​ LaTeX ​ Go Recirculation Factor = (1+(Volume of Recirculated Sewage/Volume of Raw Sewage))/(1+0.1*(Volume of Recirculated Sewage/Volume of Raw Sewage))^2
Recirculation Factor given Recirculation Ratio
​ LaTeX ​ Go Recirculation Factor = (1+Recirculation Ratio)/(1+0.1*Recirculation Ratio)^2
Recirculation Ratio given Volume of Raw Sewage
​ LaTeX ​ Go Recirculation Ratio = Volume of Recirculated Sewage/Volume of Raw Sewage
Volume of Raw Sewage given Recirculation Ratio
​ LaTeX ​ Go Volume of Raw Sewage = Volume of Recirculated Sewage/Recirculation Ratio

Efficiency of Single Stage High Rate Trickling Filter Formula

​LaTeX ​Go
Efficiency of First Filter Stage = (100/(1+0.0044*sqrt(Total Organic Load/(Volume*Recirculation Factor))))
E1 = (100/(1+0.0044*sqrt(Y/(VT*F))))

What is Filtration Efficiency?

Filtration efficiency is usually stated in terms of the percentage of particles of a certain size that would be stopped and retained by a filter medium.

How to Calculate Efficiency of Single Stage High Rate Trickling Filter?

Efficiency of Single Stage High Rate Trickling Filter calculator uses Efficiency of First Filter Stage = (100/(1+0.0044*sqrt(Total Organic Load/(Volume*Recirculation Factor)))) to calculate the Efficiency of First Filter Stage, The Efficiency of Single Stage High Rate Trickling Filter formula is defined as the ability to remove organic matter from wastewater. This efficiency is usually quantified in terms of the percentage reduction of biochemical oxygen demand (BOD) or chemical oxygen demand (COD) after the wastewater passes through the filter. Efficiency of First Filter Stage is denoted by E1 symbol.

How to calculate Efficiency of Single Stage High Rate Trickling Filter using this online calculator? To use this online calculator for Efficiency of Single Stage High Rate Trickling Filter, enter Total Organic Load (Y), Volume (VT) & Recirculation Factor (F) and hit the calculate button. Here is how the Efficiency of Single Stage High Rate Trickling Filter calculation can be explained with given input values -> 99.98467 = (100/(1+0.0044*sqrt(0.000925925925925926/(0.63*1.116)))).

FAQ

What is Efficiency of Single Stage High Rate Trickling Filter?
The Efficiency of Single Stage High Rate Trickling Filter formula is defined as the ability to remove organic matter from wastewater. This efficiency is usually quantified in terms of the percentage reduction of biochemical oxygen demand (BOD) or chemical oxygen demand (COD) after the wastewater passes through the filter and is represented as E1 = (100/(1+0.0044*sqrt(Y/(VT*F)))) or Efficiency of First Filter Stage = (100/(1+0.0044*sqrt(Total Organic Load/(Volume*Recirculation Factor)))). Total organic load is the total amount of organic material present in a water or wastewater sample, Volume is the three-dimensional space occupied by a substance or object, such as water, soil, air, or any environmental medium & Recirculation factor r represents the average number of passes of the influent organic matter through the trickling filter.
How to calculate Efficiency of Single Stage High Rate Trickling Filter?
The Efficiency of Single Stage High Rate Trickling Filter formula is defined as the ability to remove organic matter from wastewater. This efficiency is usually quantified in terms of the percentage reduction of biochemical oxygen demand (BOD) or chemical oxygen demand (COD) after the wastewater passes through the filter is calculated using Efficiency of First Filter Stage = (100/(1+0.0044*sqrt(Total Organic Load/(Volume*Recirculation Factor)))). To calculate Efficiency of Single Stage High Rate Trickling Filter, you need Total Organic Load (Y), Volume (VT) & Recirculation Factor (F). With our tool, you need to enter the respective value for Total Organic Load, Volume & Recirculation Factor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Efficiency of First Filter Stage?
In this formula, Efficiency of First Filter Stage uses Total Organic Load, Volume & Recirculation Factor. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Efficiency of First Filter Stage = (100/(1+0.0044*sqrt(Organic Loading)))
  • Efficiency of First Filter Stage = (1-(0.0044*sqrt(BOD in Effluent/(Volume*Recirculation Factor)))/((100/Efficiency of Second Filter Stage)-1))*100