Fire Demand when we have Reserve Storage Solution

STEP 0: Pre-Calculation Summary
Formula Used
Fire Demand = (Reserve Storage/Duration of Fire)+Capacity of Pump
F = (VR/t)+P
This formula uses 4 Variables
Variables Used
Fire Demand - (Measured in Cubic Meter per Second) - Fire Demand is the amount of water required to extinguish fire.
Reserve Storage - (Measured in Cubic Meter) - Reserve Storage is defined in terms of the volume or capacity of reservoirs.
Duration of Fire - (Measured in Second) - Duration of Fire is the total time at which fire was present.
Capacity of Pump - (Measured in Cubic Meter per Second) - Capacity of Pump is defined in terms of discharge.
STEP 1: Convert Input(s) to Base Unit
Reserve Storage: 1960 Liter --> 1.96 Cubic Meter (Check conversion here)
Duration of Fire: 2 Day --> 172800 Second (Check conversion here)
Capacity of Pump: 120 Liter per day --> 1.38888888888889E-06 Cubic Meter per Second (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
F = (VR/t)+P --> (1.96/172800)+1.38888888888889E-06
Evaluating ... ...
F = 1.27314814814815E-05
STEP 3: Convert Result to Output's Unit
1.27314814814815E-05 Cubic Meter per Second -->1100 Liter per day (Check conversion here)
FINAL ANSWER
1100 Liter per day <-- Fire Demand
(Calculation completed in 00.004 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

8 Capacity of Distribution Reservoir Calculators

Fire Demand given Total Storage Capacity
Go Fire Demand = (Total Storage Capacity-((Numerical Coefficient a+Numerical Coefficient b+(10/24))*Average Domestic Demand)+((10/24)*Capacity of Pump))/(10/24)
Average Domestic Demand given Total Storage Capacity
Go Average Domestic Demand = (Total Storage Capacity-((10/24)*(Fire Demand-Capacity of Pump)))/(Numerical Coefficient a+Numerical Coefficient b+(10/24))
Total Storage Capacity of Reservoirs
Go Total Storage Capacity = (Numerical Coefficient a+Numerical Coefficient b+(10/24))*Average Domestic Demand+(10/24)*(Fire Demand-Capacity of Pump)
Fire Demand given Value of McDonald Coefficient
Go Fire Demand = (Total Storage Capacity-((0.2+0.1+(10/24))*Average Domestic Demand)+((10/24)*Capacity of Pump))/(10/24)
Reserve Fire Pumping Capacity when we have Reserve Storage
Go Capacity of Pump = Fire Demand-(Reserve Storage/Duration of Fire)
Duration of Fire when we have Reserve Storage
Go Duration of Fire = Reserve Storage/(Fire Demand-Capacity of Pump)
Fire Demand when we have Reserve Storage
Go Fire Demand = (Reserve Storage/Duration of Fire)+Capacity of Pump
Reserve Storage
Go Reserve Storage = (Fire Demand-Capacity of Pump)*Duration of Fire

Fire Demand when we have Reserve Storage Formula

Fire Demand = (Reserve Storage/Duration of Fire)+Capacity of Pump
F = (VR/t)+P

What is Fire Demand ?

Fire Demand is the amount of water required to extinguish fire. Or. The water required for fire fighting in a given area. Although the actual amount of water used in a year is small for fire fighting.

How to Calculate Fire Demand when we have Reserve Storage?

Fire Demand when we have Reserve Storage calculator uses Fire Demand = (Reserve Storage/Duration of Fire)+Capacity of Pump to calculate the Fire Demand, Fire Demand when we have Reserve Storage calculates the value of fire demand when we have prior information of other parameters used. Fire Demand is denoted by F symbol.

How to calculate Fire Demand when we have Reserve Storage using this online calculator? To use this online calculator for Fire Demand when we have Reserve Storage, enter Reserve Storage (VR), Duration of Fire (t) & Capacity of Pump (P) and hit the calculate button. Here is how the Fire Demand when we have Reserve Storage calculation can be explained with given input values -> 9.5E+10 = (1.96/172800)+1.38888888888889E-06.

FAQ

What is Fire Demand when we have Reserve Storage?
Fire Demand when we have Reserve Storage calculates the value of fire demand when we have prior information of other parameters used and is represented as F = (VR/t)+P or Fire Demand = (Reserve Storage/Duration of Fire)+Capacity of Pump. Reserve Storage is defined in terms of the volume or capacity of reservoirs, Duration of Fire is the total time at which fire was present & Capacity of Pump is defined in terms of discharge.
How to calculate Fire Demand when we have Reserve Storage?
Fire Demand when we have Reserve Storage calculates the value of fire demand when we have prior information of other parameters used is calculated using Fire Demand = (Reserve Storage/Duration of Fire)+Capacity of Pump. To calculate Fire Demand when we have Reserve Storage, you need Reserve Storage (VR), Duration of Fire (t) & Capacity of Pump (P). With our tool, you need to enter the respective value for Reserve Storage, Duration of Fire & Capacity of Pump and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Fire Demand?
In this formula, Fire Demand uses Reserve Storage, Duration of Fire & Capacity of Pump. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Fire Demand = (Total Storage Capacity-((Numerical Coefficient a+Numerical Coefficient b+(10/24))*Average Domestic Demand)+((10/24)*Capacity of Pump))/(10/24)
  • Fire Demand = (Total Storage Capacity-((0.2+0.1+(10/24))*Average Domestic Demand)+((10/24)*Capacity of Pump))/(10/24)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!