Fractional Active Area given Fractional Downcomer Area Solution

STEP 0: Pre-Calculation Summary
Formula Used
Fractional Active Area = 1-Fractional Downcomer Area
fa = 1-fd
This formula uses 2 Variables
Variables Used
Fractional Active Area - Fractional Active Area is defined as the ratio of active area available in a column to the total cross sectional area of the column.
Fractional Downcomer Area - Fractional Downcomer Area refers to the ratio of tower cross sectional area occupied by the downcomers on both side of column.
STEP 1: Convert Input(s) to Base Unit
Fractional Downcomer Area: 0.12 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
fa = 1-fd --> 1-0.12
Evaluating ... ...
fa = 0.88
STEP 3: Convert Result to Output's Unit
0.88 --> No Conversion Required
FINAL ANSWER
0.88 <-- Fractional Active Area
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rishi Vadodaria
Malviya National Institute Of Technology (MNIT JAIPUR ), JAIPUR
Rishi Vadodaria has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Prerana Bakli
University of Hawaiʻi at Mānoa (UH Manoa), Hawaii, USA
Prerana Bakli has verified this Calculator and 1600+ more calculators!

25 Distillation Tower Design Calculators

Relative Volatility of Two Components Based on Normal Boiling Point and Latent Heat of Vaporization
​ Go Relative Volatility = exp(0.25164*((1/Normal Boiling Point of Component 1)-(1/Normal Boiling Point of Component 2))*(Latent Heat of Vaporization of Component 1+Latent Heat of Vaporization of Component 2))
Maximum Allowable Vapor Velocity given Plate Spacing and Fluid Densities
​ Go Maximum Allowable Vapor Velocity = (-0.171*(Plate Spacing)^2+0.27*Plate Spacing-0.047)*((Liquid Density-Vapor Density in Distillation)/Vapor Density in Distillation)^0.5
Column Diameter given Maximum Vapor Rate and Maximum Vapor Velocity
​ Go Column Diameter = sqrt((4*Vapor Mass Flowrate)/(pi*Vapor Density in Distillation*Maximum Allowable Vapor Velocity))
Tower Cross Sectional Area given Gas Volumetric Flow and Flooding Velocity
​ Go Tower Cross Sectional Area = Volumetric Gas Flow/((Fractional Approach to Flooding Velocity*Flooding Velocity)*(1-Fractional Downcomer Area))
Minimum External Reflux given Compositions
​ Go External Reflux Ratio = (Distillate Composition-Equilibrium Vapor Composition)/(Equilibrium Vapor Composition-Equilibrium Liquid Composition)
Maximum Allowable Mass Velocity using Bubble Cap Trays
​ Go Maximum Allowable Mass Velocity = Entrainment Factor*(Vapor Density in Distillation*(Liquid Density-Vapor Density in Distillation)^(1/2))
Minimum Internal Reflux given Compositions
​ Go Internal Reflux Ratio = (Distillate Composition-Equilibrium Vapor Composition)/(Distillate Composition-Equilibrium Liquid Composition)
Dry Plate Pressure Drop in Distillation Column Design
​ Go Dry Plate Head Loss = 51*((Vapor Velocity Based on Hole Area/Orifice Coefficient)^2)*(Vapor Density in Distillation/Liquid Density)
Flooding Velocity in Distillation Column Design
​ Go Flooding Velocity = Capacity Factor*((Liquid Density-Vapor Density in Distillation)/Vapor Density in Distillation)^0.5
Weep Point Velocity in Distillation Column Design
​ Go Weep Point Vapor Velocity Based on Hole Area = (Weep Point Correlation Constant-0.90*(25.4-Hole Diameter))/((Vapor Density in Distillation)^0.5)
Liquid Vapor Flow Factor in Distillation Column Design
​ Go Flow Factor = (Liquid Mass Flowrate/Vapor Mass Flowrate)*((Vapor Density in Distillation/Liquid Density)^0.5)
Downcomer Residence Time in Distillation Column
​ Go Residence Time = (Downcomer Area*Clear Liquid Backup*Liquid Density)/Liquid Mass Flowrate
Internal Reflux Ratio Based on Liquid and Distillate Flowrates
​ Go Internal Reflux Ratio = Liquid Reflux Flowrate/(Liquid Reflux Flowrate+Distillate Flowrate)
Column Diameter Based on Vapor Flowrate and Mass Velocity of Vapor
​ Go Column Diameter = ((4*Vapor Mass Flowrate)/(pi*Maximum Allowable Mass Velocity))^(1/2)
Head Loss in Downcomer of Tray Tower
​ Go Downcomer Headloss = 166*((Liquid Mass Flowrate/(Liquid Density*Downcomer Area)))^2
Height of Liquid Crest over Weir
​ Go Weir Crest = (750/1000)*((Liquid Mass Flowrate/(Weir Length*Liquid Density))^(2/3))
Active Area given Gas Volumetric Flow and Flow Velocity
​ Go Active Area = Volumetric Gas Flow/(Fractional Downcomer Area*Flooding Velocity)
Fractional Downcomer Area given Total Cross Sectional Area
​ Go Fractional Downcomer Area = 2*(Downcomer Area/Tower Cross Sectional Area)
Fractional Active Area given Downcomer Area and Total Column Area
​ Go Fractional Active Area = 1-2*(Downcomer Area/Tower Cross Sectional Area)
Internal Reflux Ratio Given External Reflux Ratio
​ Go Internal Reflux Ratio = External Reflux Ratio/(External Reflux Ratio+1)
Tower Cross Sectional Area given Fractional Active Area
​ Go Tower Cross Sectional Area = Active Area/(1-Fractional Downcomer Area)
Tower Cross Sectional Area given Active Area
​ Go Tower Cross Sectional Area = Active Area/(1-Fractional Downcomer Area)
Clearance Area under Downcomer given Weir Length and Apron Height
​ Go Clearance Area Under Downcomer = Apron Height*Weir Length
Fractional Active Area given Fractional Downcomer Area
​ Go Fractional Active Area = 1-Fractional Downcomer Area
Residual Head Loss in Pressure in Distillation Column
​ Go Residual Head Loss = (12.5*10^3)/Liquid Density

Fractional Active Area given Fractional Downcomer Area Formula

Fractional Active Area = 1-Fractional Downcomer Area
fa = 1-fd

What is the Significance of Downcomer in Distillation?

The downcomer is a key component in trayed distillation columns, and its significance lies in its role in facilitating the movement of liquid within the column. In a distillation column, the downcomer is typically associated with trayed or structured packing designs. The downcomer is a conduit that allows liquid to flow from the tray above to the tray below. It plays a crucial role in distributing liquid across the column, ensuring an even and consistent flow of liquid to support effective vapor-liquid contact on the trays.

How to Calculate Fractional Active Area given Fractional Downcomer Area?

Fractional Active Area given Fractional Downcomer Area calculator uses Fractional Active Area = 1-Fractional Downcomer Area to calculate the Fractional Active Area, The Fractional Active Area given Fractional Downcomer Area formula is defined as the ratio of active area to total column area for a known value of fractional downcomer area. Fractional Active Area is denoted by fa symbol.

How to calculate Fractional Active Area given Fractional Downcomer Area using this online calculator? To use this online calculator for Fractional Active Area given Fractional Downcomer Area, enter Fractional Downcomer Area (fd) and hit the calculate button. Here is how the Fractional Active Area given Fractional Downcomer Area calculation can be explained with given input values -> 0.88 = 1-0.12.

FAQ

What is Fractional Active Area given Fractional Downcomer Area?
The Fractional Active Area given Fractional Downcomer Area formula is defined as the ratio of active area to total column area for a known value of fractional downcomer area and is represented as fa = 1-fd or Fractional Active Area = 1-Fractional Downcomer Area. Fractional Downcomer Area refers to the ratio of tower cross sectional area occupied by the downcomers on both side of column.
How to calculate Fractional Active Area given Fractional Downcomer Area?
The Fractional Active Area given Fractional Downcomer Area formula is defined as the ratio of active area to total column area for a known value of fractional downcomer area is calculated using Fractional Active Area = 1-Fractional Downcomer Area. To calculate Fractional Active Area given Fractional Downcomer Area, you need Fractional Downcomer Area (fd). With our tool, you need to enter the respective value for Fractional Downcomer Area and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Fractional Active Area?
In this formula, Fractional Active Area uses Fractional Downcomer Area. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Fractional Active Area = 1-2*(Downcomer Area/Tower Cross Sectional Area)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!