Head Loss in Downcomer of Tray Tower Solution

STEP 0: Pre-Calculation Summary
Formula Used
Downcomer Headloss = 166*((Liquid Mass Flowrate/(Liquid Density*Downcomer Area)))^2
hdc = 166*((Lw/(ρL*Ad)))^2
This formula uses 4 Variables
Variables Used
Downcomer Headloss - (Measured in Meter) - Downcomer Headloss is defined in the loss in the pressure head due to downcomer area or clearance area whichever is smaller.
Liquid Mass Flowrate - (Measured in Kilogram per Second) - Liquid Mass Flowrate is the mass flow rate of the liquid component in the column.
Liquid Density - (Measured in Kilogram per Cubic Meter) - Liquid Density is defined as the ratio of mass of given fluid with respect to the volume that it occupies.
Downcomer Area - (Measured in Square Meter) - Downcomer area refers to the section or passage that allows the liquid phase to flow from the higher tray or stage to the lower tray or stage.
STEP 1: Convert Input(s) to Base Unit
Liquid Mass Flowrate: 12.856 Kilogram per Second --> 12.856 Kilogram per Second No Conversion Required
Liquid Density: 995 Kilogram per Cubic Meter --> 995 Kilogram per Cubic Meter No Conversion Required
Downcomer Area: 0.09872 Square Meter --> 0.09872 Square Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
hdc = 166*((Lw/(ρL*Ad)))^2 --> 166*((12.856/(995*0.09872)))^2
Evaluating ... ...
hdc = 2.84356631345434
STEP 3: Convert Result to Output's Unit
2.84356631345434 Meter --> No Conversion Required
FINAL ANSWER
2.84356631345434 2.843566 Meter <-- Downcomer Headloss
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rishi Vadodaria
Malviya National Institute Of Technology (MNIT JAIPUR ), JAIPUR
Rishi Vadodaria has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Vaibhav Mishra
DJ Sanghvi College of Engineering (DJSCE), Mumbai
Vaibhav Mishra has verified this Calculator and 200+ more calculators!

25 Distillation Tower Design Calculators

Relative Volatility of Two Components Based on Normal Boiling Point and Latent Heat of Vaporization
​ Go Relative Volatility = exp(0.25164*((1/Normal Boiling Point of Component 1)-(1/Normal Boiling Point of Component 2))*(Latent Heat of Vaporization of Component 1+Latent Heat of Vaporization of Component 2))
Maximum Allowable Vapor Velocity given Plate Spacing and Fluid Densities
​ Go Maximum Allowable Vapor Velocity = (-0.171*(Plate Spacing)^2+0.27*Plate Spacing-0.047)*((Liquid Density-Vapor Density in Distillation)/Vapor Density in Distillation)^0.5
Column Diameter given Maximum Vapor Rate and Maximum Vapor Velocity
​ Go Column Diameter = sqrt((4*Vapor Mass Flowrate)/(pi*Vapor Density in Distillation*Maximum Allowable Vapor Velocity))
Tower Cross Sectional Area given Gas Volumetric Flow and Flooding Velocity
​ Go Tower Cross Sectional Area = Volumetric Gas Flow/((Fractional Approach to Flooding Velocity*Flooding Velocity)*(1-Fractional Downcomer Area))
Minimum External Reflux given Compositions
​ Go External Reflux Ratio = (Distillate Composition-Equilibrium Vapor Composition)/(Equilibrium Vapor Composition-Equilibrium Liquid Composition)
Maximum Allowable Mass Velocity using Bubble Cap Trays
​ Go Maximum Allowable Mass Velocity = Entrainment Factor*(Vapor Density in Distillation*(Liquid Density-Vapor Density in Distillation)^(1/2))
Minimum Internal Reflux given Compositions
​ Go Internal Reflux Ratio = (Distillate Composition-Equilibrium Vapor Composition)/(Distillate Composition-Equilibrium Liquid Composition)
Dry Plate Pressure Drop in Distillation Column Design
​ Go Dry Plate Head Loss = 51*((Vapor Velocity Based on Hole Area/Orifice Coefficient)^2)*(Vapor Density in Distillation/Liquid Density)
Flooding Velocity in Distillation Column Design
​ Go Flooding Velocity = Capacity Factor*((Liquid Density-Vapor Density in Distillation)/Vapor Density in Distillation)^0.5
Weep Point Velocity in Distillation Column Design
​ Go Weep Point Vapor Velocity Based on Hole Area = (Weep Point Correlation Constant-0.90*(25.4-Hole Diameter))/((Vapor Density in Distillation)^0.5)
Liquid Vapor Flow Factor in Distillation Column Design
​ Go Flow Factor = (Liquid Mass Flowrate/Vapor Mass Flowrate)*((Vapor Density in Distillation/Liquid Density)^0.5)
Downcomer Residence Time in Distillation Column
​ Go Residence Time = (Downcomer Area*Clear Liquid Backup*Liquid Density)/Liquid Mass Flowrate
Internal Reflux Ratio Based on Liquid and Distillate Flowrates
​ Go Internal Reflux Ratio = Liquid Reflux Flowrate/(Liquid Reflux Flowrate+Distillate Flowrate)
Column Diameter Based on Vapor Flowrate and Mass Velocity of Vapor
​ Go Column Diameter = ((4*Vapor Mass Flowrate)/(pi*Maximum Allowable Mass Velocity))^(1/2)
Head Loss in Downcomer of Tray Tower
​ Go Downcomer Headloss = 166*((Liquid Mass Flowrate/(Liquid Density*Downcomer Area)))^2
Height of Liquid Crest over Weir
​ Go Weir Crest = (750/1000)*((Liquid Mass Flowrate/(Weir Length*Liquid Density))^(2/3))
Active Area given Gas Volumetric Flow and Flow Velocity
​ Go Active Area = Volumetric Gas Flow/(Fractional Downcomer Area*Flooding Velocity)
Fractional Downcomer Area given Total Cross Sectional Area
​ Go Fractional Downcomer Area = 2*(Downcomer Area/Tower Cross Sectional Area)
Fractional Active Area given Downcomer Area and Total Column Area
​ Go Fractional Active Area = 1-2*(Downcomer Area/Tower Cross Sectional Area)
Internal Reflux Ratio Given External Reflux Ratio
​ Go Internal Reflux Ratio = External Reflux Ratio/(External Reflux Ratio+1)
Tower Cross Sectional Area given Fractional Active Area
​ Go Tower Cross Sectional Area = Active Area/(1-Fractional Downcomer Area)
Tower Cross Sectional Area given Active Area
​ Go Tower Cross Sectional Area = Active Area/(1-Fractional Downcomer Area)
Clearance Area under Downcomer given Weir Length and Apron Height
​ Go Clearance Area Under Downcomer = Apron Height*Weir Length
Fractional Active Area given Fractional Downcomer Area
​ Go Fractional Active Area = 1-Fractional Downcomer Area
Residual Head Loss in Pressure in Distillation Column
​ Go Residual Head Loss = (12.5*10^3)/Liquid Density

Head Loss in Downcomer of Tray Tower Formula

Downcomer Headloss = 166*((Liquid Mass Flowrate/(Liquid Density*Downcomer Area)))^2
hdc = 166*((Lw/(ρL*Ad)))^2

What is Head Loss in Downcomer in Distillation?

Head loss in the downcomer of a distillation column is the reduction in pressure experienced by the liquid as it flows from a higher tray (stage) to a lower one through the downcomer. This head loss is a crucial factor in the design and operation of distillation columns as it affects the distribution of liquid and vapor flow within the column. The head loss in the downcomer can be caused by various factors, including frictional resistance, changes in velocity, and changes in elevation.

How to Calculate Head Loss in Downcomer of Tray Tower?

Head Loss in Downcomer of Tray Tower calculator uses Downcomer Headloss = 166*((Liquid Mass Flowrate/(Liquid Density*Downcomer Area)))^2 to calculate the Downcomer Headloss, The Head Loss in Downcomer of Tray Tower formula is defined as loss in Pressure head in the section or passage that allows the liquid phase (typically condensed vapor or reflux) to flow from the higher tray or stage to the lower tray or stage. Downcomer Headloss is denoted by hdc symbol.

How to calculate Head Loss in Downcomer of Tray Tower using this online calculator? To use this online calculator for Head Loss in Downcomer of Tray Tower, enter Liquid Mass Flowrate (Lw), Liquid Density L) & Downcomer Area (Ad) and hit the calculate button. Here is how the Head Loss in Downcomer of Tray Tower calculation can be explained with given input values -> 2.843566 = 166*((12.856/(995*0.09872)))^2.

FAQ

What is Head Loss in Downcomer of Tray Tower?
The Head Loss in Downcomer of Tray Tower formula is defined as loss in Pressure head in the section or passage that allows the liquid phase (typically condensed vapor or reflux) to flow from the higher tray or stage to the lower tray or stage and is represented as hdc = 166*((Lw/(ρL*Ad)))^2 or Downcomer Headloss = 166*((Liquid Mass Flowrate/(Liquid Density*Downcomer Area)))^2. Liquid Mass Flowrate is the mass flow rate of the liquid component in the column, Liquid Density is defined as the ratio of mass of given fluid with respect to the volume that it occupies & Downcomer area refers to the section or passage that allows the liquid phase to flow from the higher tray or stage to the lower tray or stage.
How to calculate Head Loss in Downcomer of Tray Tower?
The Head Loss in Downcomer of Tray Tower formula is defined as loss in Pressure head in the section or passage that allows the liquid phase (typically condensed vapor or reflux) to flow from the higher tray or stage to the lower tray or stage is calculated using Downcomer Headloss = 166*((Liquid Mass Flowrate/(Liquid Density*Downcomer Area)))^2. To calculate Head Loss in Downcomer of Tray Tower, you need Liquid Mass Flowrate (Lw), Liquid Density L) & Downcomer Area (Ad). With our tool, you need to enter the respective value for Liquid Mass Flowrate, Liquid Density & Downcomer Area and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.