Download Heat Transfer from Extended Surfaces (Fins), Critical Thickness of Insulation and Thermal Resistance PDF

Related PDFs (10)

Basics of Heat Transfer
Formulas : 17   Size : 374 kb
Basics of Modes of Heat Transfer
Formulas : 13   Size : 394 kb
Boiling
Formulas : 14   Size : 400 kb
Condensation
Formulas : 22   Size : 417 kb
Convection Heat Transfer
Formulas : 31   Size : 458 kb
Co-Relation of Dimensionless Numbers
Formulas : 11   Size : 327 kb
Heat Exchanger and its Effectiveness
Formulas : 15   Size : 385 kb
Unsteady State Heat Conduction
Formulas : 18   Size : 394 kb

Contents of the Heat Transfer from Extended Surfaces (Fins), Critical Thickness of Insulation and Thermal Resistance PDF

List of 20 Heat Transfer from Extended Surfaces (Fins), Critical Thickness of Insulation and Thermal Resistance Formulas

Biot Number using Characteristic Length
Correction Length for Cylindrical Fin with Non-Adiabatic Tip
Correction Length for Square Fin with Non-Adiabatic Tip
Correction Length for Thin Rectangular Fin with Non-Adiabatic Tip
Critical Radius of Insulation of Cylinder
Critical Radius of Insulation of Hollow Sphere
Heat Dissipation from Fin Insulated at End Tip
Heat Dissipation from Fin Losing Heat at End Tip
Heat Dissipation from Infinitely Long Fin
Heat Transfer in Fins given Fin Efficiency
Inner Heat Transfer Coefficient given Inner Thermal Resistance
Inside Area given Thermal Resistance for Inner Surface
Newton's Law of Cooling
Outside Area given Outer Thermal Resistance
Outside Heat Transfer Coefficient given Thermal Resistance
Thermal Resistance for Conduction at Tube Wall
Thermal Resistance for Convection at Inner Surface
Thermal Resistance for Convection at Outer Surface
Total Thermal Resistance
Volumetric Heat Generation in Current Carrying Electrical Conductor

Variables used in Heat Transfer from Extended Surfaces (Fins), Critical Thickness of Insulation and Thermal Resistance PDF

  1. A Area (Square Meter)
  2. Ac Cross Sectional Area (Square Meter)
  3. Ainside Inside Area (Square Meter)
  4. Aoutside Outside Area (Square Meter)
  5. Bi Biot Number
  6. dfin Diameter of Cylindrical Fin (Meter)
  7. hinside Inside Convection Heat Transfer Coefficient (Watt per Square Meter per Kelvin)
  8. houtside External Convection Heat Transfer Coefficient (Watt per Square Meter per Kelvin)
  9. htransfer Heat Transfer Coefficient (Watt per Square Meter per Kelvin)
  10. i Electric Current Density (Ampere per Square Meter)
  11. k Thermal Conductivity (Watt per Meter per K)
  12. kfin Thermal Conductivity of Fin (Watt per Meter per K)
  13. Kinsulation Thermal Conductivity of Insulation (Watt per Meter per K)
  14. l Length of Cylinder (Meter)
  15. Lchar Characteristic Length (Meter)
  16. Lcylindrical Correction Length for Cylindrical Fin (Meter)
  17. Lfin Length of Fin (Meter)
  18. Lrectangular Correction Length for Thin Rectangular Fin (Meter)
  19. Lsqaure Correction Length for Sqaure Fin (Meter)
  20. Pfin Perimeter of Fin (Meter)
  21. q' Heat Flux (Watt per Square Meter)
  22. Qfin Fin Heat Transfer Rate (Watt)
  23. qg Volumetric Heat Generation (Watt Per Cubic Meter)
  24. r1 Inner Radius of Cylinder (Meter)
  25. r2 Outer Radius of Cylinder (Meter)
  26. Rc Critical Radius of Insulation (Meter)
  27. Rth Thermal Resistance (Kelvin per Watt)
  28. Tf Temperature of Characteristic Fluid (Kelvin)
  29. tfin Thickness of Fin (Meter)
  30. Ts Surrounding Temperature (Kelvin)
  31. Tw Surface Temperature (Kelvin)
  32. Uoverall Overall Heat Transfer Coefficient (Watt per Square Meter per Kelvin)
  33. wfin Width of Fin (Meter)
  34. ΔT Overall Difference in Temperature (Kelvin)
  35. η Fin Efficiency
  36. ρ Resistivity (Ohm Meter)
  37. ΣRthermal Total Thermal Resistance (Kelvin per Watt)

Constants, Functions and Measurements used in Heat Transfer from Extended Surfaces (Fins), Critical Thickness of Insulation and Thermal Resistance PDF

  1. Constant: pi, 3.14159265358979323846264338327950288
    Archimedes' constant
  2. Function: ln, ln(Number)
    The natural logarithm, also known as the logarithm to the base e, is the inverse function of the natural exponential function.
  3. Function: sqrt, sqrt(Number)
    A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
  4. Function: tanh, tanh(Number)
    The hyperbolic tangent function (tanh) is a function that is defined as the ratio of the hyperbolic sine function (sinh) to the hyperbolic cosine function (cosh).
  5. Measurement: Length in Meter (m)
    Length Unit Conversion
  6. Measurement: Temperature in Kelvin (K)
    Temperature Unit Conversion
  7. Measurement: Area in Square Meter (m²)
    Area Unit Conversion
  8. Measurement: Power in Watt (W)
    Power Unit Conversion
  9. Measurement: Surface Current Density in Ampere per Square Meter (A/m²)
    Surface Current Density Unit Conversion
  10. Measurement: Thermal Resistance in Kelvin per Watt (K/W)
    Thermal Resistance Unit Conversion
  11. Measurement: Thermal Conductivity in Watt per Meter per K (W/(m*K))
    Thermal Conductivity Unit Conversion
  12. Measurement: Electric Resistivity in Ohm Meter (Ω*m)
    Electric Resistivity Unit Conversion
  13. Measurement: Heat Flux Density in Watt per Square Meter (W/m²)
    Heat Flux Density Unit Conversion
  14. Measurement: Heat Transfer Coefficient in Watt per Square Meter per Kelvin (W/m²*K)
    Heat Transfer Coefficient Unit Conversion
  15. Measurement: Power Density in Watt Per Cubic Meter (W/m³)
    Power Density Unit Conversion

Free Heat Transfer from Extended Surfaces (Fins), Critical Thickness of Insulation and Thermal Resistance PDF

Get Free Heat Transfer from Extended Surfaces (Fins), Critical Thickness of Insulation and Thermal Resistance PDF for Download today. Examples are included after each Formula with a link to a live Calculator! All the Formulas and Calculators support Unit Conversion as well. This PDF features 20 calculators from Chemical Engineering. Inside, you'll discover a list of formulas such as Biot Number using Characteristic Length, Correction Length for Cylindrical Fin with Non-Adiabatic Tip and 20 more formulas!. The Variables, Functions and Constants are summarized at the end. Explore and share Heat Transfer from Extended Surfaces (Fins), Critical Thickness of Insulation and Thermal Resistance PDFs!

Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!