Influent BOD given Overall Efficiency of Two-Stage Trickling Filter Solution

STEP 0: Pre-Calculation Summary
Formula Used
Influent BOD = (100*Effluent BOD)/(100-Overall Efficiency)
Qi = (100*Qo)/(100-E)
This formula uses 3 Variables
Variables Used
Influent BOD - (Measured in Kilogram per Cubic Meter) - Influent BOD refers to the total amount of BOD which is present in the incoming sewage.
Effluent BOD - (Measured in Kilogram per Cubic Meter) - Effluent BOD refers to the amount of BOD present in the outing sewage.
Overall Efficiency - Overall Efficiency refers to the total efficiency of the trickling filter. It is calculated in percentage.
STEP 1: Convert Input(s) to Base Unit
Effluent BOD: 0.002362 Milligram per Liter --> 2.362E-06 Kilogram per Cubic Meter (Check conversion ​here)
Overall Efficiency: 2.39 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Qi = (100*Qo)/(100-E) --> (100*2.362E-06)/(100-2.39)
Evaluating ... ...
Qi = 2.41983403339822E-06
STEP 3: Convert Result to Output's Unit
2.41983403339822E-06 Kilogram per Cubic Meter -->0.00241983403339822 Milligram per Liter (Check conversion ​here)
FINAL ANSWER
0.00241983403339822 0.00242 Milligram per Liter <-- Influent BOD
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Ishita Goyal LinkedIn Logo
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Chandana P Dev LinkedIn Logo
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

Influent and Effluent BOD Calculators

Influent BOD given BOD Loading for First Stage Filter
​ LaTeX ​ Go Influent BOD = BOD Loading to Filter 2/(Waste Water Flow*8.34)
Influent BOD given Overall Efficiency of Two-Stage Trickling Filter
​ LaTeX ​ Go Influent BOD = (100*Effluent BOD)/(100-Overall Efficiency)
Effluent BOD given Overall Efficiency of Two-Stage Trickling Filter
​ LaTeX ​ Go Effluent BOD = (1-(Overall Efficiency/100))*Influent BOD

Influent BOD given Overall Efficiency of Two-Stage Trickling Filter Formula

​LaTeX ​Go
Influent BOD = (100*Effluent BOD)/(100-Overall Efficiency)
Qi = (100*Qo)/(100-E)

What is Trickling Filter?

Trickling Filter is a type of wastewater treatment system. It consists of a fixed bed of rocks, coke, gravel, slag, polyurethane foam, sphagnum peat moss, ceramic, or plastic media over which sewage or other wastewater flows downward and causes a layer of microbial slime (biofilm) to grow, covering the bed of media.

How to Calculate Influent BOD given Overall Efficiency of Two-Stage Trickling Filter?

Influent BOD given Overall Efficiency of Two-Stage Trickling Filter calculator uses Influent BOD = (100*Effluent BOD)/(100-Overall Efficiency) to calculate the Influent BOD, The Influent BOD given Overall Efficiency of Two-Stage Trickling Filter formula is defined as the BOD levels in the untreated wastewater entering a treatment plant. Influent BOD is denoted by Qi symbol.

How to calculate Influent BOD given Overall Efficiency of Two-Stage Trickling Filter using this online calculator? To use this online calculator for Influent BOD given Overall Efficiency of Two-Stage Trickling Filter, enter Effluent BOD (Qo) & Overall Efficiency (E) and hit the calculate button. Here is how the Influent BOD given Overall Efficiency of Two-Stage Trickling Filter calculation can be explained with given input values -> 2.379441 = (100*2.362E-06)/(100-2.39).

FAQ

What is Influent BOD given Overall Efficiency of Two-Stage Trickling Filter?
The Influent BOD given Overall Efficiency of Two-Stage Trickling Filter formula is defined as the BOD levels in the untreated wastewater entering a treatment plant and is represented as Qi = (100*Qo)/(100-E) or Influent BOD = (100*Effluent BOD)/(100-Overall Efficiency). Effluent BOD refers to the amount of BOD present in the outing sewage & Overall Efficiency refers to the total efficiency of the trickling filter. It is calculated in percentage.
How to calculate Influent BOD given Overall Efficiency of Two-Stage Trickling Filter?
The Influent BOD given Overall Efficiency of Two-Stage Trickling Filter formula is defined as the BOD levels in the untreated wastewater entering a treatment plant is calculated using Influent BOD = (100*Effluent BOD)/(100-Overall Efficiency). To calculate Influent BOD given Overall Efficiency of Two-Stage Trickling Filter, you need Effluent BOD (Qo) & Overall Efficiency (E). With our tool, you need to enter the respective value for Effluent BOD & Overall Efficiency and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Influent BOD?
In this formula, Influent BOD uses Effluent BOD & Overall Efficiency. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Influent BOD = BOD Loading to Filter 2/(Waste Water Flow*8.34)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!