Initial Efficiency given Final Efficiency after Two Stage Filtration Solution

STEP 0: Pre-Calculation Summary
Formula Used
Efficiency of First Filter Stage = (1-(0.0044*sqrt(BOD in Effluent/(Volume*Recirculation Factor)))/((100/Efficiency of Second Filter Stage)-1))*100
E1 = (1-(0.0044*sqrt(Y'/(VT*F)))/((100/E2)-1))*100
This formula uses 1 Functions, 5 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Efficiency of First Filter Stage - Efficiency of first filter stage calculates the efficiency of the filter at the first stage.
BOD in Effluent - (Measured in Kilogram per Second) - BOD in Effluent means total BOD in effluent from 1st stage.
Volume - (Measured in Cubic Meter) - Volume is the three-dimensional space occupied by a substance or object, such as water, soil, air, or any environmental medium.
Recirculation Factor - Recirculation factor r represents the average number of passes of the influent organic matter through the trickling filter.
Efficiency of Second Filter Stage - Efficiency of second filter stage is the total efficiency obtained from the second trickling filter.
STEP 1: Convert Input(s) to Base Unit
BOD in Effluent: 3 Kilogram per Day --> 3.47222222222222E-05 Kilogram per Second (Check conversion ​here)
Volume: 0.63 Cubic Meter --> 0.63 Cubic Meter No Conversion Required
Recirculation Factor: 1.116 --> No Conversion Required
Efficiency of Second Filter Stage: 99 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
E1 = (1-(0.0044*sqrt(Y'/(VT*F)))/((100/E2)-1))*100 --> (1-(0.0044*sqrt(3.47222222222222E-05/(0.63*1.116)))/((100/99)-1))*100
Evaluating ... ...
E1 = 99.6938817265542
STEP 3: Convert Result to Output's Unit
99.6938817265542 --> No Conversion Required
FINAL ANSWER
99.6938817265542 99.69388 <-- Efficiency of First Filter Stage
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Efficiency of High Rate Filters Calculators

Recirculation Factor given Volume of Raw Sewage
​ Go Recirculation Factor = (1+(Volume of Recirculated Sewage/Volume of Raw Sewage))/(1+0.1*(Volume of Recirculated Sewage/Volume of Raw Sewage))^2
Recirculation Factor given Recirculation Ratio
​ Go Recirculation Factor = (1+Recirculation Ratio)/(1+0.1*Recirculation Ratio)^2
Recirculation Ratio given Volume of Raw Sewage
​ Go Recirculation Ratio = Volume of Recirculated Sewage/Volume of Raw Sewage
Volume of Raw Sewage given Recirculation Ratio
​ Go Volume of Raw Sewage = Volume of Recirculated Sewage/Recirculation Ratio

Initial Efficiency given Final Efficiency after Two Stage Filtration Formula

Efficiency of First Filter Stage = (1-(0.0044*sqrt(BOD in Effluent/(Volume*Recirculation Factor)))/((100/Efficiency of Second Filter Stage)-1))*100
E1 = (1-(0.0044*sqrt(Y'/(VT*F)))/((100/E2)-1))*100

What is Filtration Efficiency?

Filtration efficiency is usually stated in terms of the percentage of particles of a certain size that would be stopped and retained by a filter medium.

How to Calculate Initial Efficiency given Final Efficiency after Two Stage Filtration?

Initial Efficiency given Final Efficiency after Two Stage Filtration calculator uses Efficiency of First Filter Stage = (1-(0.0044*sqrt(BOD in Effluent/(Volume*Recirculation Factor)))/((100/Efficiency of Second Filter Stage)-1))*100 to calculate the Efficiency of First Filter Stage, The Initial Efficiency given Final Efficiency after Two Stage Filtration formula is defined as the effectiveness of a filtration system (or a stage of filtration) in removing contaminants from a water sample at the beginning of its operation. This value is typically expressed as a percentage and indicates how well the system performs initially. Efficiency of First Filter Stage is denoted by E1 symbol.

How to calculate Initial Efficiency given Final Efficiency after Two Stage Filtration using this online calculator? To use this online calculator for Initial Efficiency given Final Efficiency after Two Stage Filtration, enter BOD in Effluent (Y'), Volume (VT), Recirculation Factor (F) & Efficiency of Second Filter Stage (E2) and hit the calculate button. Here is how the Initial Efficiency given Final Efficiency after Two Stage Filtration calculation can be explained with given input values -> 99.70601 = (1-(0.0044*sqrt(3.47222222222222E-05/(0.63*1.116)))/((100/99)-1))*100.

FAQ

What is Initial Efficiency given Final Efficiency after Two Stage Filtration?
The Initial Efficiency given Final Efficiency after Two Stage Filtration formula is defined as the effectiveness of a filtration system (or a stage of filtration) in removing contaminants from a water sample at the beginning of its operation. This value is typically expressed as a percentage and indicates how well the system performs initially and is represented as E1 = (1-(0.0044*sqrt(Y'/(VT*F)))/((100/E2)-1))*100 or Efficiency of First Filter Stage = (1-(0.0044*sqrt(BOD in Effluent/(Volume*Recirculation Factor)))/((100/Efficiency of Second Filter Stage)-1))*100. BOD in Effluent means total BOD in effluent from 1st stage, Volume is the three-dimensional space occupied by a substance or object, such as water, soil, air, or any environmental medium, Recirculation factor r represents the average number of passes of the influent organic matter through the trickling filter & Efficiency of second filter stage is the total efficiency obtained from the second trickling filter.
How to calculate Initial Efficiency given Final Efficiency after Two Stage Filtration?
The Initial Efficiency given Final Efficiency after Two Stage Filtration formula is defined as the effectiveness of a filtration system (or a stage of filtration) in removing contaminants from a water sample at the beginning of its operation. This value is typically expressed as a percentage and indicates how well the system performs initially is calculated using Efficiency of First Filter Stage = (1-(0.0044*sqrt(BOD in Effluent/(Volume*Recirculation Factor)))/((100/Efficiency of Second Filter Stage)-1))*100. To calculate Initial Efficiency given Final Efficiency after Two Stage Filtration, you need BOD in Effluent (Y'), Volume (VT), Recirculation Factor (F) & Efficiency of Second Filter Stage (E2). With our tool, you need to enter the respective value for BOD in Effluent, Volume, Recirculation Factor & Efficiency of Second Filter Stage and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Efficiency of First Filter Stage?
In this formula, Efficiency of First Filter Stage uses BOD in Effluent, Volume, Recirculation Factor & Efficiency of Second Filter Stage. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Efficiency of First Filter Stage = (100/(1+0.0044*sqrt(Total Organic Load/(Volume*Recirculation Factor))))
  • Efficiency of First Filter Stage = (100/(1+0.0044*sqrt(Organic Loading)))