Internal Reflux Ratio Based on Liquid and Distillate Flowrates Solution

STEP 0: Pre-Calculation Summary
Formula Used
Internal Reflux Ratio = Liquid Reflux Flowrate/(Liquid Reflux Flowrate+Distillate Flowrate)
Rin = L/(L+D)
This formula uses 3 Variables
Variables Used
Internal Reflux Ratio - Internal Reflux Ratio refers to the ratio of liquid refluxed back to the column and the amount of vapor flowing out from the top of column.
Liquid Reflux Flowrate - (Measured in Cubic Meter per Second) - Liquid reflux flowrate refers to the amount of liquid returning or flowing back in a distillation process.
Distillate Flowrate - (Measured in Cubic Meter per Second) - The distillate flowrate refers to the rate at which the distilled or separated product is collected during a distillation process.
STEP 1: Convert Input(s) to Base Unit
Liquid Reflux Flowrate: 1.2547 Cubic Meter per Second --> 1.2547 Cubic Meter per Second No Conversion Required
Distillate Flowrate: 0.875264 Cubic Meter per Second --> 0.875264 Cubic Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Rin = L/(L+D) --> 1.2547/(1.2547+0.875264)
Evaluating ... ...
Rin = 0.589070988993241
STEP 3: Convert Result to Output's Unit
0.589070988993241 --> No Conversion Required
FINAL ANSWER
0.589070988993241 0.589071 <-- Internal Reflux Ratio
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rishi Vadodaria
Malviya National Institute Of Technology (MNIT JAIPUR ), JAIPUR
Rishi Vadodaria has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Prerana Bakli
University of Hawaiʻi at Mānoa (UH Manoa), Hawaii, USA
Prerana Bakli has verified this Calculator and 1600+ more calculators!

25 Distillation Tower Design Calculators

Relative Volatility of Two Components Based on Normal Boiling Point and Latent Heat of Vaporization
​ Go Relative Volatility = exp(0.25164*((1/Normal Boiling Point of Component 1)-(1/Normal Boiling Point of Component 2))*(Latent Heat of Vaporization of Component 1+Latent Heat of Vaporization of Component 2))
Maximum Allowable Vapor Velocity given Plate Spacing and Fluid Densities
​ Go Maximum Allowable Vapor Velocity = (-0.171*(Plate Spacing)^2+0.27*Plate Spacing-0.047)*((Liquid Density-Vapor Density in Distillation)/Vapor Density in Distillation)^0.5
Column Diameter given Maximum Vapor Rate and Maximum Vapor Velocity
​ Go Column Diameter = sqrt((4*Vapor Mass Flowrate)/(pi*Vapor Density in Distillation*Maximum Allowable Vapor Velocity))
Tower Cross Sectional Area given Gas Volumetric Flow and Flooding Velocity
​ Go Tower Cross Sectional Area = Volumetric Gas Flow/((Fractional Approach to Flooding Velocity*Flooding Velocity)*(1-Fractional Downcomer Area))
Minimum External Reflux given Compositions
​ Go External Reflux Ratio = (Distillate Composition-Equilibrium Vapor Composition)/(Equilibrium Vapor Composition-Equilibrium Liquid Composition)
Maximum Allowable Mass Velocity using Bubble Cap Trays
​ Go Maximum Allowable Mass Velocity = Entrainment Factor*(Vapor Density in Distillation*(Liquid Density-Vapor Density in Distillation)^(1/2))
Minimum Internal Reflux given Compositions
​ Go Internal Reflux Ratio = (Distillate Composition-Equilibrium Vapor Composition)/(Distillate Composition-Equilibrium Liquid Composition)
Dry Plate Pressure Drop in Distillation Column Design
​ Go Dry Plate Head Loss = 51*((Vapor Velocity Based on Hole Area/Orifice Coefficient)^2)*(Vapor Density in Distillation/Liquid Density)
Flooding Velocity in Distillation Column Design
​ Go Flooding Velocity = Capacity Factor*((Liquid Density-Vapor Density in Distillation)/Vapor Density in Distillation)^0.5
Weep Point Velocity in Distillation Column Design
​ Go Weep Point Vapor Velocity Based on Hole Area = (Weep Point Correlation Constant-0.90*(25.4-Hole Diameter))/((Vapor Density in Distillation)^0.5)
Liquid Vapor Flow Factor in Distillation Column Design
​ Go Flow Factor = (Liquid Mass Flowrate/Vapor Mass Flowrate)*((Vapor Density in Distillation/Liquid Density)^0.5)
Downcomer Residence Time in Distillation Column
​ Go Residence Time = (Downcomer Area*Clear Liquid Backup*Liquid Density)/Liquid Mass Flowrate
Internal Reflux Ratio Based on Liquid and Distillate Flowrates
​ Go Internal Reflux Ratio = Liquid Reflux Flowrate/(Liquid Reflux Flowrate+Distillate Flowrate)
Column Diameter Based on Vapor Flowrate and Mass Velocity of Vapor
​ Go Column Diameter = ((4*Vapor Mass Flowrate)/(pi*Maximum Allowable Mass Velocity))^(1/2)
Head Loss in Downcomer of Tray Tower
​ Go Downcomer Headloss = 166*((Liquid Mass Flowrate/(Liquid Density*Downcomer Area)))^2
Height of Liquid Crest over Weir
​ Go Weir Crest = (750/1000)*((Liquid Mass Flowrate/(Weir Length*Liquid Density))^(2/3))
Active Area given Gas Volumetric Flow and Flow Velocity
​ Go Active Area = Volumetric Gas Flow/(Fractional Downcomer Area*Flooding Velocity)
Fractional Downcomer Area given Total Cross Sectional Area
​ Go Fractional Downcomer Area = 2*(Downcomer Area/Tower Cross Sectional Area)
Fractional Active Area given Downcomer Area and Total Column Area
​ Go Fractional Active Area = 1-2*(Downcomer Area/Tower Cross Sectional Area)
Internal Reflux Ratio Given External Reflux Ratio
​ Go Internal Reflux Ratio = External Reflux Ratio/(External Reflux Ratio+1)
Tower Cross Sectional Area given Fractional Active Area
​ Go Tower Cross Sectional Area = Active Area/(1-Fractional Downcomer Area)
Tower Cross Sectional Area given Active Area
​ Go Tower Cross Sectional Area = Active Area/(1-Fractional Downcomer Area)
Clearance Area under Downcomer given Weir Length and Apron Height
​ Go Clearance Area Under Downcomer = Apron Height*Weir Length
Fractional Active Area given Fractional Downcomer Area
​ Go Fractional Active Area = 1-Fractional Downcomer Area
Residual Head Loss in Pressure in Distillation Column
​ Go Residual Head Loss = (12.5*10^3)/Liquid Density

Internal Reflux Ratio Based on Liquid and Distillate Flowrates Formula

Internal Reflux Ratio = Liquid Reflux Flowrate/(Liquid Reflux Flowrate+Distillate Flowrate)
Rin = L/(L+D)

What is the significance of internal reflux ratio?

The internal reflux ratio is a crucial parameter in distillation processes and plays a significant role in determining the efficiency of the separation achieved within a distillation column. The internal reflux ratio impacts the vapor-liquid equilibrium conditions in the distillation column. This is crucial for achieving the desired separation of components based on their boiling points. The internal reflux ratio is a critical parameter in distillation processes, impacting the separation efficiency, temperature profile, and energy consumption of the system.

How to Calculate Internal Reflux Ratio Based on Liquid and Distillate Flowrates?

Internal Reflux Ratio Based on Liquid and Distillate Flowrates calculator uses Internal Reflux Ratio = Liquid Reflux Flowrate/(Liquid Reflux Flowrate+Distillate Flowrate) to calculate the Internal Reflux Ratio, The Internal Reflux Ratio Based on Liquid and Distillate Flowrates formula is defined as the ratio of the liquid reflux flowrate (L) to the distillate flowrate (D). Internal Reflux Ratio is denoted by Rin symbol.

How to calculate Internal Reflux Ratio Based on Liquid and Distillate Flowrates using this online calculator? To use this online calculator for Internal Reflux Ratio Based on Liquid and Distillate Flowrates, enter Liquid Reflux Flowrate (L) & Distillate Flowrate (D) and hit the calculate button. Here is how the Internal Reflux Ratio Based on Liquid and Distillate Flowrates calculation can be explained with given input values -> 0.589071 = 1.2547/(1.2547+0.875264).

FAQ

What is Internal Reflux Ratio Based on Liquid and Distillate Flowrates?
The Internal Reflux Ratio Based on Liquid and Distillate Flowrates formula is defined as the ratio of the liquid reflux flowrate (L) to the distillate flowrate (D) and is represented as Rin = L/(L+D) or Internal Reflux Ratio = Liquid Reflux Flowrate/(Liquid Reflux Flowrate+Distillate Flowrate). Liquid reflux flowrate refers to the amount of liquid returning or flowing back in a distillation process & The distillate flowrate refers to the rate at which the distilled or separated product is collected during a distillation process.
How to calculate Internal Reflux Ratio Based on Liquid and Distillate Flowrates?
The Internal Reflux Ratio Based on Liquid and Distillate Flowrates formula is defined as the ratio of the liquid reflux flowrate (L) to the distillate flowrate (D) is calculated using Internal Reflux Ratio = Liquid Reflux Flowrate/(Liquid Reflux Flowrate+Distillate Flowrate). To calculate Internal Reflux Ratio Based on Liquid and Distillate Flowrates, you need Liquid Reflux Flowrate (L) & Distillate Flowrate (D). With our tool, you need to enter the respective value for Liquid Reflux Flowrate & Distillate Flowrate and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Internal Reflux Ratio?
In this formula, Internal Reflux Ratio uses Liquid Reflux Flowrate & Distillate Flowrate. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Internal Reflux Ratio = External Reflux Ratio/(External Reflux Ratio+1)
  • Internal Reflux Ratio = (Distillate Composition-Equilibrium Vapor Composition)/(Distillate Composition-Equilibrium Liquid Composition)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!