Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 500+ more calculators!
Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 500+ more calculators!

11 Other formulas that you can solve using the same Inputs

Negative Sequence Impedance For Delta Connected Load
Negative Sequence Impedance=Negative Sequence Voltage/Negative Sequence Current GO
Negative Sequence Impedance For Star Connected Load
Negative Sequence Impedance=Negative Sequence Voltage/Negative Sequence Current GO
Negative Sequence Impedance For Transformer
Negative Sequence Impedance=Negative Sequence Voltage/Negative Sequence Current GO
Negative Sequence Voltage For Delta Connected Load
Negative Sequence Voltage=Delta Impedance *Negative Sequence Current /3 GO
Negative Phase Current For Delta Connected Load
Negative Sequence Current =3*Negative Sequence Voltage/Delta Impedance GO
Leakage Impedance For Transformer Using Negative Sequence Current
Leakage Impedance=Negative Sequence Voltage/Negative Sequence Current GO
Delta Impedance For Delta Connected Load Using Negative Sequence Voltage
Delta Impedance =Negative Sequence Voltage/Negative Sequence Current GO
Star Impedance For Star Connected Load Using Negative Sequence Voltage
Star Impedance =Negative Sequence Voltage/Negative Sequence Current GO
Star Impedance For Star Connected Load Using Negative Sequence Current
Star Impedance =Negative Sequence Voltage/Negative Sequence Current GO
Negative Sequence Voltage For Star Connected Load
Negative Sequence Voltage=Negative Sequence Current *Star Impedance GO
Negative Sequence Current For Star Connected Load
Negative Sequence Current =Negative Sequence Voltage/Star Impedance GO

5 Other formulas that calculate the same Output

Leakage Impedance For transformer Using Zero Sequence Voltage
Leakage Impedance=(Zero Sequence Voltage/Zero Sequence Current )-3*Neutral Impedance GO
Leakage Impedance For Transformer Using Zero Sequence Current
Leakage Impedance=(Zero Sequence Voltage/Zero Sequence Current )-3*Neutral Impedance GO
Leakage Impedance For Transformer Using Positive Sequence Voltage
Leakage Impedance=Positive Sequence Voltage/Positive Sequence Current GO
Leakage Impedance For Transformer Using Positive Sequence Current
Leakage Impedance=Positive Sequence Voltage/Positive Sequence Current GO
Leakage Impedance For Transformer Using Negative Sequence Current
Leakage Impedance=Negative Sequence Voltage/Negative Sequence Current GO

Leakage Impedance For transformer Using Negative Sequence Voltage Formula

Leakage Impedance=Negative Sequence Voltage/Negative Sequence Current
Zleakage=V2/I2
More formulas
Zero Sequence Impedance For Star Connected Load GO
Negative Sequence Impedance For Star Connected Load GO
Positive Sequence Impedance For Star Connected Load GO
Positive Sequence Impedance For Delta Connected Load GO
Negative Sequence Impedance For Delta Connected Load GO
Zero Sequence Impedance For Delta Connected Load GO
Positive Sequence Impedance For transformer GO
Negative Sequence Impedance For Transformer GO
Zero Sequence Impedance For transformer GO
Symmetric Component Voltage Using Sequence Impedance GO
Sequence Impedance GO
Symmetric Component Current Using Sequence Impedance GO
Negative Sequence Voltage For Star Connected Load GO
Zero Sequence Voltage For Star Connected Load GO
Positive Sequence Voltage For Delta Connected Load GO
Positive Sequence Voltage For Star Connected Load GO
Negative Sequence Voltage For Delta Connected Load GO
Positive Sequence Current For Star Connected Load GO
Negative Sequence Current For Star Connected Load GO
Zero Sequence current For Star Connected Load GO
Negative Phase Current For Delta Connected Load GO
Positive Sequence Current For Delta Connected Load GO
Leakage Impedance For Transformer Using Positive Sequence Voltage GO
Leakage Impedance For transformer Using Zero Sequence Voltage GO
Leakage Impedance For Transformer Using Positive Sequence Current GO
Leakage Impedance For Transformer Using Negative Sequence Current GO
Leakage Impedance For Transformer Using Zero Sequence Current GO
Star Impedance For Star Connected Load Using Negative Sequence Voltage GO
Star Impedance For Star Connected Load Using Positive Sequence Voltage GO
Star Impedance For Star Connected Load Using Zero Sequence Voltage GO
Neutral Impedance For Star Connected Load Using Zero Sequence Voltage GO
Star Impedance For Star Connected Load Using Negative Sequence Current GO
Star Impedance For Star Connected Load Using Positive Sequence Current GO
Star Impedance For Star Connected Load Using Zero Sequence Current GO
Delta Impedance For Delta Connected Load Using Negative Sequence Voltage GO
Positive Sequence Voltage (LLF) GO
Star Impedance Using Delta Impedance GO

What are the Sequence Components?

The positive sequence consists of balanced three-phase voltage and current phasors which are exactly at "120 degrees apart rotating counterclockwise in ABC rotation. The negative sequence consists of balanced three-phase voltage and current phasors which are exactly at "120 degrees apart rotating counterclockwise in ACB rotation. Zero sequence consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counterclockwise together.

How to Calculate Leakage Impedance For transformer Using Negative Sequence Voltage?

Leakage Impedance For transformer Using Negative Sequence Voltage calculator uses Leakage Impedance=Negative Sequence Voltage/Negative Sequence Current to calculate the Leakage Impedance, The Leakage Impedance For transformer Using Negative Sequence Voltage formula is defined as the part of the impedance of a transformer that corresponds to the leakage flux into the sequence network. Leakage Impedance and is denoted by Zleakage symbol.

How to calculate Leakage Impedance For transformer Using Negative Sequence Voltage using this online calculator? To use this online calculator for Leakage Impedance For transformer Using Negative Sequence Voltage, enter Negative Sequence Voltage (V2) and Negative Sequence Current (I2) and hit the calculate button. Here is how the Leakage Impedance For transformer Using Negative Sequence Voltage calculation can be explained with given input values -> 0.571429 = 4/7.

FAQ

What is Leakage Impedance For transformer Using Negative Sequence Voltage?
The Leakage Impedance For transformer Using Negative Sequence Voltage formula is defined as the part of the impedance of a transformer that corresponds to the leakage flux into the sequence network and is represented as Zleakage=V2/I2 or Leakage Impedance=Negative Sequence Voltage/Negative Sequence Current . Negative Sequence Voltage consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation and Negative Sequence Current consists of balanced three-phase current phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation.
How to calculate Leakage Impedance For transformer Using Negative Sequence Voltage?
The Leakage Impedance For transformer Using Negative Sequence Voltage formula is defined as the part of the impedance of a transformer that corresponds to the leakage flux into the sequence network is calculated using Leakage Impedance=Negative Sequence Voltage/Negative Sequence Current . To calculate Leakage Impedance For transformer Using Negative Sequence Voltage, you need Negative Sequence Voltage (V2) and Negative Sequence Current (I2). With our tool, you need to enter the respective value for Negative Sequence Voltage and Negative Sequence Current and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Leakage Impedance?
In this formula, Leakage Impedance uses Negative Sequence Voltage and Negative Sequence Current . We can use 5 other way(s) to calculate the same, which is/are as follows -
  • Leakage Impedance=Positive Sequence Voltage/Positive Sequence Current
  • Leakage Impedance=(Zero Sequence Voltage/Zero Sequence Current )-3*Neutral Impedance
  • Leakage Impedance=Positive Sequence Voltage/Positive Sequence Current
  • Leakage Impedance=Negative Sequence Voltage/Negative Sequence Current
  • Leakage Impedance=(Zero Sequence Voltage/Zero Sequence Current )-3*Neutral Impedance
Share Image
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!