Length of Sedimentation Tank with respect to Height of Settling Zone for Practical Purpose Solution

STEP 0: Pre-Calculation Summary
Formula Used
Length of sedimentation tank = 10*Height of Crack
LS = 10*h
This formula uses 2 Variables
Variables Used
Length of sedimentation tank - (Measured in Meter) - Length of sedimentation tank is the bottom is slightly sloped to facilitate sludge scraping. The general dimension of a sedimentation tank are as follows: Length = 4 × Width.
Height of Crack - (Measured in Meter) - Height of Crack is the size of a flaw or crack in a material that can lead to catastrophic failure under a given stress.
STEP 1: Convert Input(s) to Base Unit
Height of Crack: 12000 Millimeter --> 12 Meter (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
LS = 10*h --> 10*12
Evaluating ... ...
LS = 120
STEP 3: Convert Result to Output's Unit
120 Meter --> No Conversion Required
FINAL ANSWER
120 Meter <-- Length of sedimentation tank
(Calculation completed in 00.004 seconds)

Credits

Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 600+ more calculators!

3 Length of Sedimentation Tank Calculators

Length of Sedimentation Tank with respect to Darcy Weishbach Friction Factor
Go Length of sedimentation tank = Height of Crack*sqrt(8/Darcy Friction Factor)
Length of Sedimentation Tank with respect to Surface Area
Go Length of sedimentation tank = Height of Crack*Area/Cross-Sectional Area
Length of Sedimentation Tank with respect to Height of Settling Zone for Practical Purpose
Go Length of sedimentation tank = 10*Height of Crack

Length of Sedimentation Tank with respect to Height of Settling Zone for Practical Purpose Formula

Length of sedimentation tank = 10*Height of Crack
LS = 10*h

What is sedimentation?

Sedimentation is a physical water treatment process using gravity to remove suspended solids from water. Solid particles entrained by the turbulence of moving water may be removed naturally by sedimentation in the still water of lakes and oceans.

How to Calculate Length of Sedimentation Tank with respect to Height of Settling Zone for Practical Purpose?

Length of Sedimentation Tank with respect to Height of Settling Zone for Practical Purpose calculator uses Length of sedimentation tank = 10*Height of Crack to calculate the Length of sedimentation tank, The Length of Sedimentation Tank with respect to Height of Settling Zone for Practical Purpose is the distance from one end of the tank to the other end of the sedimentation tank. Length of sedimentation tank is denoted by LS symbol.

How to calculate Length of Sedimentation Tank with respect to Height of Settling Zone for Practical Purpose using this online calculator? To use this online calculator for Length of Sedimentation Tank with respect to Height of Settling Zone for Practical Purpose, enter Height of Crack (h) and hit the calculate button. Here is how the Length of Sedimentation Tank with respect to Height of Settling Zone for Practical Purpose calculation can be explained with given input values -> 120 = 10*12.

FAQ

What is Length of Sedimentation Tank with respect to Height of Settling Zone for Practical Purpose?
The Length of Sedimentation Tank with respect to Height of Settling Zone for Practical Purpose is the distance from one end of the tank to the other end of the sedimentation tank and is represented as LS = 10*h or Length of sedimentation tank = 10*Height of Crack. Height of Crack is the size of a flaw or crack in a material that can lead to catastrophic failure under a given stress.
How to calculate Length of Sedimentation Tank with respect to Height of Settling Zone for Practical Purpose?
The Length of Sedimentation Tank with respect to Height of Settling Zone for Practical Purpose is the distance from one end of the tank to the other end of the sedimentation tank is calculated using Length of sedimentation tank = 10*Height of Crack. To calculate Length of Sedimentation Tank with respect to Height of Settling Zone for Practical Purpose, you need Height of Crack (h). With our tool, you need to enter the respective value for Height of Crack and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Length of sedimentation tank?
In this formula, Length of sedimentation tank uses Height of Crack. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Length of sedimentation tank = Height of Crack*Area/Cross-Sectional Area
  • Length of sedimentation tank = Height of Crack*sqrt(8/Darcy Friction Factor)