Load Current of DC Three Phase Uncontrolled Rectifier Solution

STEP 0: Pre-Calculation Summary
Formula Used
DC Load Current = (3*sqrt(3)*Peak Input Voltage)/(2*pi*Load Resistance)
IL(dc) = (3*sqrt(3)*Vmax)/(2*pi*RL)
This formula uses 1 Constants, 1 Functions, 3 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
DC Load Current - (Measured in Ampere) - DC Load Current of uncontrolled rectifier is the current that flows through the load.
Peak Input Voltage - (Measured in Volt) - Peak Input Voltage is the peak of the alternating voltage provided at the input of any electrical circuit.
Load Resistance - (Measured in Ohm) - Load Resistance of uncontrolled rectifier is a type of rectifier circuit that uses a resistive load to convert AC voltage to DC voltage.
STEP 1: Convert Input(s) to Base Unit
Peak Input Voltage: 220 Volt --> 220 Volt No Conversion Required
Load Resistance: 6.99 Ohm --> 6.99 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
IL(dc) = (3*sqrt(3)*Vmax)/(2*pi*RL) --> (3*sqrt(3)*220)/(2*pi*6.99)
Evaluating ... ...
IL(dc) = 26.0284027881533
STEP 3: Convert Result to Output's Unit
26.0284027881533 Ampere --> No Conversion Required
FINAL ANSWER
26.0284027881533 26.0284 Ampere <-- DC Load Current
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Mohamed Fazil V
Acharya institute of technology (AIT), Bengaluru
Mohamed Fazil V has created this Calculator and 50+ more calculators!
Verifier Image
Verified by Parminder Singh
Chandigarh University (CU), Punjab
Parminder Singh has verified this Calculator and 600+ more calculators!

9 Full Wave Calculators

RMS Load Current of Three Phase Uncontrolled Rectifier
​ Go RMS Load Current = (Winding Ratio*Peak Input Voltage)/(Load Resistance*sqrt(2))*sqrt(1+(3*sqrt(3))/(2*pi))
RMS Diode Current of Three Phase Uncontrolled Rectifier
​ Go RMS Diode Current = (Winding Ratio*Peak Input Voltage)/(Load Resistance*sqrt(2))*sqrt(1/3+sqrt(3)/(4*pi))
RMS Load Voltage of Three Phase Uncontrolled Rectifier
​ Go RMS Load Voltage = (Winding Ratio*Peak Input Voltage)/sqrt(2)*sqrt(1+(3*sqrt(3))/(2*pi))
Average Load Current of Three Phase Uncontrolled Rectifier
​ Go Average Load Current = (3*sqrt(3)*Winding Ratio*Peak Input Voltage)/(2*pi*Load Resistance)
Average Diode Current of Three Phase Uncontrolled Rectifier
​ Go Average Diode Current = (sqrt(3)*Winding Ratio*Peak Input Voltage)/(2*pi*Load Resistance)
Load Current of DC Three Phase Uncontrolled Rectifier
​ Go DC Load Current = (3*sqrt(3)*Peak Input Voltage)/(2*pi*Load Resistance)
Load Voltage of DC Three Phase Uncontrolled Rectifier
​ Go DC Load Voltage = (3*sqrt(3)*Peak Input Voltage)/(2*pi)
Load Voltage of Full Wave Three Phase Uncontrolled Rectifier
​ Go AC Voltage = (2*Winding Ratio*Peak Input Voltage)/pi
Power Delivered to Load in Three Phase Uncontrolled Rectifier
​ Go Delivery Power = AC Voltage*Average Output Voltage

Load Current of DC Three Phase Uncontrolled Rectifier Formula

DC Load Current = (3*sqrt(3)*Peak Input Voltage)/(2*pi*Load Resistance)
IL(dc) = (3*sqrt(3)*Vmax)/(2*pi*RL)

What is Load Current of dc Three Phase Uncontrolled Rectifier?

The load current of a DC three-phase uncontrolled rectifier depends on the configuration of the rectifier, the type of load, and the input AC voltage. Common configurations include the six-pulse and twelve-pulse rectifiers. I'll provide a basic calculation for the load current in a six-pulse three-phase uncontrolled rectifier. In a six-pulse rectifier, the load current can be calculated based on the peak value of the AC input current and the configuration of the rectifier.

How to Calculate Load Current of DC Three Phase Uncontrolled Rectifier?

Load Current of DC Three Phase Uncontrolled Rectifier calculator uses DC Load Current = (3*sqrt(3)*Peak Input Voltage)/(2*pi*Load Resistance) to calculate the DC Load Current, Load Current of dc Three Phase Uncontrolled Rectifier is the current that flows through the load. The load current of a three-phase uncontrolled rectifier is the same as the average diode current. This is because the load current is divided equally among the three diodes in the rectifier circuit. The load current in a three-phase uncontrolled rectifier is typically higher than the load current in a single-phase uncontrolled rectifier. This is because the three-phase rectifier has a lower ripple factor than the single-phase rectifier. The ripple factor is a measure of how much AC component is present in the DC output voltage. A lower ripple factor means that the DC output voltage is closer to a pure DC voltage, and the load current will be higher. DC Load Current is denoted by IL(dc) symbol.

How to calculate Load Current of DC Three Phase Uncontrolled Rectifier using this online calculator? To use this online calculator for Load Current of DC Three Phase Uncontrolled Rectifier, enter Peak Input Voltage (Vmax) & Load Resistance (RL) and hit the calculate button. Here is how the Load Current of DC Three Phase Uncontrolled Rectifier calculation can be explained with given input values -> 26.0284 = (3*sqrt(3)*220)/(2*pi*6.99).

FAQ

What is Load Current of DC Three Phase Uncontrolled Rectifier?
Load Current of dc Three Phase Uncontrolled Rectifier is the current that flows through the load. The load current of a three-phase uncontrolled rectifier is the same as the average diode current. This is because the load current is divided equally among the three diodes in the rectifier circuit. The load current in a three-phase uncontrolled rectifier is typically higher than the load current in a single-phase uncontrolled rectifier. This is because the three-phase rectifier has a lower ripple factor than the single-phase rectifier. The ripple factor is a measure of how much AC component is present in the DC output voltage. A lower ripple factor means that the DC output voltage is closer to a pure DC voltage, and the load current will be higher and is represented as IL(dc) = (3*sqrt(3)*Vmax)/(2*pi*RL) or DC Load Current = (3*sqrt(3)*Peak Input Voltage)/(2*pi*Load Resistance). Peak Input Voltage is the peak of the alternating voltage provided at the input of any electrical circuit & Load Resistance of uncontrolled rectifier is a type of rectifier circuit that uses a resistive load to convert AC voltage to DC voltage.
How to calculate Load Current of DC Three Phase Uncontrolled Rectifier?
Load Current of dc Three Phase Uncontrolled Rectifier is the current that flows through the load. The load current of a three-phase uncontrolled rectifier is the same as the average diode current. This is because the load current is divided equally among the three diodes in the rectifier circuit. The load current in a three-phase uncontrolled rectifier is typically higher than the load current in a single-phase uncontrolled rectifier. This is because the three-phase rectifier has a lower ripple factor than the single-phase rectifier. The ripple factor is a measure of how much AC component is present in the DC output voltage. A lower ripple factor means that the DC output voltage is closer to a pure DC voltage, and the load current will be higher is calculated using DC Load Current = (3*sqrt(3)*Peak Input Voltage)/(2*pi*Load Resistance). To calculate Load Current of DC Three Phase Uncontrolled Rectifier, you need Peak Input Voltage (Vmax) & Load Resistance (RL). With our tool, you need to enter the respective value for Peak Input Voltage & Load Resistance and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!