Maximum Yield Coefficient given Observed Cell Yield Solution

STEP 0: Pre-Calculation Summary
Formula Used
Maximum Yield Coefficient = Observed Cell Yield-(Endogenous decay coefficient*Mean Cell Residence Time)
Y = Yobs-(kd*θc)
This formula uses 4 Variables
Variables Used
Maximum Yield Coefficient - Maximum Yield Coefficient Y represents the maximum mg of cells produced per mg organic matter removed.
Observed Cell Yield - Observed Cell Yield is the observed mg of cells produced per mg organic matter removed.
Endogenous decay coefficient - (Measured in 1 Per Second) - Endogenous decay coefficient is a coefficient representing the decrease of cell mass in the MLVSS.
Mean Cell Residence Time - (Measured in Second) - Mean Cell Residence Time is the average time that the sludge remains in the reactor.
STEP 1: Convert Input(s) to Base Unit
Observed Cell Yield: 0.8 --> No Conversion Required
Endogenous decay coefficient: 0.05 1 Per Day --> 5.78703703703704E-07 1 Per Second (Check conversion here)
Mean Cell Residence Time: 7 Day --> 604800 Second (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Y = Yobs-(kdc) --> 0.8-(5.78703703703704E-07*604800)
Evaluating ... ...
Y = 0.45
STEP 3: Convert Result to Output's Unit
0.45 --> No Conversion Required
FINAL ANSWER
0.45 <-- Maximum Yield Coefficient
(Calculation completed in 00.004 seconds)

Credits

Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

2 Maximum Yield Coefficient Calculators

Maximum Yield Coefficient given Volume of Reactor
Go Maximum Yield Coefficient = Reactor Volume*MLVSS*(1+(Mean Cell Residence Time*Endogenous decay coefficient))/(Mean Cell Residence Time*Average daily influent flow rate*(Influent Substrate Concentration-Effluent substrate concentration))
Maximum Yield Coefficient given Observed Cell Yield
Go Maximum Yield Coefficient = Observed Cell Yield-(Endogenous decay coefficient*Mean Cell Residence Time)

Maximum Yield Coefficient given Observed Cell Yield Formula

Maximum Yield Coefficient = Observed Cell Yield-(Endogenous decay coefficient*Mean Cell Residence Time)
Y = Yobs-(kd*θc)

What is observed cell yield?

The Observed cell yield represents the observed mg of cells produced per mg organic matter removed. The observed cell yield is always less than the maximum cell yield, (Y).

How to Calculate Maximum Yield Coefficient given Observed Cell Yield?

Maximum Yield Coefficient given Observed Cell Yield calculator uses Maximum Yield Coefficient = Observed Cell Yield-(Endogenous decay coefficient*Mean Cell Residence Time) to calculate the Maximum Yield Coefficient, Maximum Yield Coefficient given Observed Cell Yield Y represents the maximum mg of cells produced per mg organic matter removed. Maximum Yield Coefficient is denoted by Y symbol.

How to calculate Maximum Yield Coefficient given Observed Cell Yield using this online calculator? To use this online calculator for Maximum Yield Coefficient given Observed Cell Yield, enter Observed Cell Yield (Yobs), Endogenous decay coefficient (kd) & Mean Cell Residence Time c) and hit the calculate button. Here is how the Maximum Yield Coefficient given Observed Cell Yield calculation can be explained with given input values -> 0.3 = 0.8-(5.78703703703704E-07*604800).

FAQ

What is Maximum Yield Coefficient given Observed Cell Yield?
Maximum Yield Coefficient given Observed Cell Yield Y represents the maximum mg of cells produced per mg organic matter removed and is represented as Y = Yobs-(kdc) or Maximum Yield Coefficient = Observed Cell Yield-(Endogenous decay coefficient*Mean Cell Residence Time). Observed Cell Yield is the observed mg of cells produced per mg organic matter removed, Endogenous decay coefficient is a coefficient representing the decrease of cell mass in the MLVSS & Mean Cell Residence Time is the average time that the sludge remains in the reactor.
How to calculate Maximum Yield Coefficient given Observed Cell Yield?
Maximum Yield Coefficient given Observed Cell Yield Y represents the maximum mg of cells produced per mg organic matter removed is calculated using Maximum Yield Coefficient = Observed Cell Yield-(Endogenous decay coefficient*Mean Cell Residence Time). To calculate Maximum Yield Coefficient given Observed Cell Yield, you need Observed Cell Yield (Yobs), Endogenous decay coefficient (kd) & Mean Cell Residence Time c). With our tool, you need to enter the respective value for Observed Cell Yield, Endogenous decay coefficient & Mean Cell Residence Time and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Maximum Yield Coefficient?
In this formula, Maximum Yield Coefficient uses Observed Cell Yield, Endogenous decay coefficient & Mean Cell Residence Time. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Maximum Yield Coefficient = Reactor Volume*MLVSS*(1+(Mean Cell Residence Time*Endogenous decay coefficient))/(Mean Cell Residence Time*Average daily influent flow rate*(Influent Substrate Concentration-Effluent substrate concentration))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!