Mean Temperature in Entire Catchment given Run-off in cm Solution

STEP 0: Pre-Calculation Summary
Formula Used
Temperature = ((Rainfall Depth in Centimeters-Runoff Depth)*3.74)+32
T = ((Pcm-Rcm)*3.74)+32
This formula uses 3 Variables
Variables Used
Temperature - (Measured in Kelvin) - Temperature is the degree or intensity of heat present in a substance or object.
Rainfall Depth in Centimeters - (Measured in Meter) - Rainfall Depth in Centimeters is the total amount of rain falling over a catchment area in terms of depth.
Runoff Depth - (Measured in Meter) - Runoff Depth at the measuring point in the receiving water results in the arithmetical mean of the values of the total runoff depth.
STEP 1: Convert Input(s) to Base Unit
Rainfall Depth in Centimeters: 10 Centimeter --> 0.1 Meter (Check conversion here)
Runoff Depth: 2 Centimeter --> 0.02 Meter (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
T = ((Pcm-Rcm)*3.74)+32 --> ((0.1-0.02)*3.74)+32
Evaluating ... ...
T = 32.2992
STEP 3: Convert Result to Output's Unit
32.2992 Kelvin --> No Conversion Required
FINAL ANSWER
32.2992 Kelvin <-- Temperature
(Calculation completed in 00.004 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

6 Khosla's Formula Calculators

Mean Temperature in Entire Catchment given Run-off
Go Temperature = ((Rainfall Depth in Centimeters-Runoff Depth in Inches)*9.5)+32
Mean Temperature in Entire Catchment given Run-off in cm
Go Temperature = ((Rainfall Depth in Centimeters-Runoff Depth)*3.74)+32
Rainfall in cm by Khosla's Formula
Go Rainfall Depth in Centimeters = Runoff Depth+((Temperature-32)/3.74)
Run-off in cm by Khosla's Formula
Go Runoff Depth = Rainfall Depth in Centimeters-((Temperature-32)/3.74)
Rainfall in Inches by Khosla's Formula
Go Rainfall Depth = Runoff Depth in Inches+((Temperature-32)/9.5)
Run-off in Inches by Khosla's Formula
Go Runoff Depth in Inches = Rainfall Depth-((Temperature-32)/9.5)

Mean Temperature in Entire Catchment given Run-off in cm Formula

Temperature = ((Rainfall Depth in Centimeters-Runoff Depth)*3.74)+32
T = ((Pcm-Rcm)*3.74)+32

What is Catchment Area ?

A catchment is an area of land where water collects when it rains, often bounded by hills. As the water flows over the landscape it finds its way into streams and down into the soil, eventually feeding the river.

How to Calculate Mean Temperature in Entire Catchment given Run-off in cm?

Mean Temperature in Entire Catchment given Run-off in cm calculator uses Temperature = ((Rainfall Depth in Centimeters-Runoff Depth)*3.74)+32 to calculate the Temperature, The Mean Temperature in Entire Catchment given Run-off in cm is defined as the value of mean temperature when we have prior information of other parameters used. Temperature is denoted by T symbol.

How to calculate Mean Temperature in Entire Catchment given Run-off in cm using this online calculator? To use this online calculator for Mean Temperature in Entire Catchment given Run-off in cm, enter Rainfall Depth in Centimeters (Pcm) & Runoff Depth (Rcm) and hit the calculate button. Here is how the Mean Temperature in Entire Catchment given Run-off in cm calculation can be explained with given input values -> 32.2992 = ((0.1-0.02)*3.74)+32.

FAQ

What is Mean Temperature in Entire Catchment given Run-off in cm?
The Mean Temperature in Entire Catchment given Run-off in cm is defined as the value of mean temperature when we have prior information of other parameters used and is represented as T = ((Pcm-Rcm)*3.74)+32 or Temperature = ((Rainfall Depth in Centimeters-Runoff Depth)*3.74)+32. Rainfall Depth in Centimeters is the total amount of rain falling over a catchment area in terms of depth & Runoff Depth at the measuring point in the receiving water results in the arithmetical mean of the values of the total runoff depth.
How to calculate Mean Temperature in Entire Catchment given Run-off in cm?
The Mean Temperature in Entire Catchment given Run-off in cm is defined as the value of mean temperature when we have prior information of other parameters used is calculated using Temperature = ((Rainfall Depth in Centimeters-Runoff Depth)*3.74)+32. To calculate Mean Temperature in Entire Catchment given Run-off in cm, you need Rainfall Depth in Centimeters (Pcm) & Runoff Depth (Rcm). With our tool, you need to enter the respective value for Rainfall Depth in Centimeters & Runoff Depth and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Temperature?
In this formula, Temperature uses Rainfall Depth in Centimeters & Runoff Depth. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Temperature = ((Rainfall Depth in Centimeters-Runoff Depth in Inches)*9.5)+32
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!