Overall Efficiency of Two Stage Trickling Filter Solution

STEP 0: Pre-Calculation Summary
Formula Used
Overall efficiency TF = (Influent BOD-Effluent BOD/Influent BOD)*100
E = (Qi-Qo/Qi)*100
This formula uses 3 Variables
Variables Used
Overall efficiency TF - Overall efficiency TF is the total efficiency of the trickling filter. It is calculated in percentage.
Influent BOD - (Measured in Kilogram per Cubic Meter) - Influent BOD is the total amount of BOD which is present in the incoming sewage.
Effluent BOD - (Measured in Kilogram per Cubic Meter) - Effluent BOD is the amount of BOD present in the outing sewage.
STEP 1: Convert Input(s) to Base Unit
Influent BOD: 24 Milligram per Liter --> 0.024 Kilogram per Cubic Meter (Check conversion here)
Effluent BOD: 0.4 Milligram per Liter --> 0.0004 Kilogram per Cubic Meter (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
E = (Qi-Qo/Qi)*100 --> (0.024-0.0004/0.024)*100
Evaluating ... ...
E = 0.733333333333333
STEP 3: Convert Result to Output's Unit
0.733333333333333 --> No Conversion Required
FINAL ANSWER
0.733333333333333 0.733333 <-- Overall efficiency TF
(Calculation completed in 00.004 seconds)

Credits

Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

7 Efficiency of Filter Calculators

Efficiency of Second Filter Stage
Go Efficiency of Second Filter Stage = 100/(1+((0.0561/(1-Efficiency of First Filter Stage))*sqrt(BOD Loading to Filter 2/(Volume*Recirculation factor))))
Efficiency of First Filter Stage using Efficiency of Second Filter Stage
Go Efficiency of First Filter Stage = 1+((0.0561/(100/Efficiency of Second Filter Stage)-1)*sqrt(BOD Loading to Filter 2/(Volume*Recirculation factor)))
Efficiency of First Filter Stage
Go Efficiency of First Filter Stage = 100/(1+(0.0561*sqrt(BOD Loading to Filter 2/(Volume*Recirculation factor))))
Efficiency of First Filter Stage given Overall Efficiency
Go Efficiency of First Filter Stage = (Overall efficiency TF-Efficiency of Second Filter Stage)/(1-Efficiency of Second Filter Stage)
Efficiency of Second Filter Stage given Overall Efficiency
Go Efficiency of Second Filter Stage = (Overall efficiency TF-Efficiency of First Filter Stage)/(1-Efficiency of First Filter Stage)
Efficiency of First Filter given BOD Loading for Second Filter
Go Efficiency of First Filter Stage = 1-(BOD5 loading to the second stage filter/BOD Loading to Filter 2)
Overall Efficiency of Two Stage Trickling Filter
Go Overall efficiency TF = (Influent BOD-Effluent BOD/Influent BOD)*100

Overall Efficiency of Two Stage Trickling Filter Formula

Overall efficiency TF = (Influent BOD-Effluent BOD/Influent BOD)*100
E = (Qi-Qo/Qi)*100

What is a trickling filter?

A trickling filter is a type of wastewater treatment system. It consists of a fixed bed of rocks, coke, gravel, slag, polyurethane foam, sphagnum peat moss, ceramic, or plastic media over which sewage or other wastewater flows downward and causes a layer of microbial slime (biofilm) to grow, covering the bed of media.

How to Calculate Overall Efficiency of Two Stage Trickling Filter?

Overall Efficiency of Two Stage Trickling Filter calculator uses Overall efficiency TF = (Influent BOD-Effluent BOD/Influent BOD)*100 to calculate the Overall efficiency TF, Overall Efficiency of Two Stage Trickling Filter is the total efficiency obtained after the waste passes from 2 filters. Overall efficiency TF is denoted by E symbol.

How to calculate Overall Efficiency of Two Stage Trickling Filter using this online calculator? To use this online calculator for Overall Efficiency of Two Stage Trickling Filter, enter Influent BOD (Qi) & Effluent BOD (Qo) and hit the calculate button. Here is how the Overall Efficiency of Two Stage Trickling Filter calculation can be explained with given input values -> -2.451429 = (0.024-0.0004/0.024)*100.

FAQ

What is Overall Efficiency of Two Stage Trickling Filter?
Overall Efficiency of Two Stage Trickling Filter is the total efficiency obtained after the waste passes from 2 filters and is represented as E = (Qi-Qo/Qi)*100 or Overall efficiency TF = (Influent BOD-Effluent BOD/Influent BOD)*100. Influent BOD is the total amount of BOD which is present in the incoming sewage & Effluent BOD is the amount of BOD present in the outing sewage.
How to calculate Overall Efficiency of Two Stage Trickling Filter?
Overall Efficiency of Two Stage Trickling Filter is the total efficiency obtained after the waste passes from 2 filters is calculated using Overall efficiency TF = (Influent BOD-Effluent BOD/Influent BOD)*100. To calculate Overall Efficiency of Two Stage Trickling Filter, you need Influent BOD (Qi) & Effluent BOD (Qo). With our tool, you need to enter the respective value for Influent BOD & Effluent BOD and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!