Oxygen Equivalent given Organic Matter Present at Start of BOD Solution

STEP 0: Pre-Calculation Summary
Formula Used
Oxygen Equivalent = Organic Matter at Start*10^(-Deoxygenation Constant*Time in days)
Lt = L*10^(-KD*t)
This formula uses 4 Variables
Variables Used
Oxygen Equivalent - (Measured in Kilogram per Cubic Meter) - Oxygen Equivalent is the oxidisable organic matter present in sewage.
Organic Matter at Start - (Measured in Kilogram per Cubic Meter) - Organic Matter at Start is the total organic matter present in the sewage at the start of the BOD reaction.
Deoxygenation Constant - (Measured in 1 Per Second) - Deoxygenation Constant is the value obtained after decomposing of oxygen in sewage.
Time in days - (Measured in Second) - Time in days is the time calculated in days.
STEP 1: Convert Input(s) to Base Unit
Organic Matter at Start: 40 Milligram per Liter --> 0.04 Kilogram per Cubic Meter (Check conversion here)
Deoxygenation Constant: 0.23 1 Per Day --> 2.66203703703704E-06 1 Per Second (Check conversion here)
Time in days: 10 Day --> 864000 Second (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Lt = L*10^(-KD*t) --> 0.04*10^(-2.66203703703704E-06*864000)
Evaluating ... ...
Lt = 0.000200474893450908
STEP 3: Convert Result to Output's Unit
0.000200474893450908 Kilogram per Cubic Meter -->0.200474893450908 Milligram per Liter (Check conversion here)
FINAL ANSWER
0.200474893450908 0.200475 Milligram per Liter <-- Oxygen Equivalent
(Calculation completed in 00.020 seconds)

Credits

Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 600+ more calculators!

2 Oxygen Equivalent Calculators

Constant of Integration given Oxygen Equivalent
Go Integration Constant = log(Oxygen Equivalent,e)+(Rate Constant in BOD*Time in days)
Oxygen Equivalent given Organic Matter Present at Start of BOD
Go Oxygen Equivalent = Organic Matter at Start*10^(-Deoxygenation Constant*Time in days)

Oxygen Equivalent given Organic Matter Present at Start of BOD Formula

Oxygen Equivalent = Organic Matter at Start*10^(-Deoxygenation Constant*Time in days)
Lt = L*10^(-KD*t)

What is BOD?

BOD is a measure of the amount of oxygen required to remove waste organic matter from water in the process of decomposition by aerobic bacteria

How to Calculate Oxygen Equivalent given Organic Matter Present at Start of BOD?

Oxygen Equivalent given Organic Matter Present at Start of BOD calculator uses Oxygen Equivalent = Organic Matter at Start*10^(-Deoxygenation Constant*Time in days) to calculate the Oxygen Equivalent, The Oxygen Equivalent given Organic Matter Present at Start of BOD is defined as the oxidizable organic matter present in the sewage after t days from the start of oxidation. Oxygen Equivalent is denoted by Lt symbol.

How to calculate Oxygen Equivalent given Organic Matter Present at Start of BOD using this online calculator? To use this online calculator for Oxygen Equivalent given Organic Matter Present at Start of BOD, enter Organic Matter at Start (L), Deoxygenation Constant (KD) & Time in days (t) and hit the calculate button. Here is how the Oxygen Equivalent given Organic Matter Present at Start of BOD calculation can be explained with given input values -> 200.4749 = 0.04*10^(-2.66203703703704E-06*864000).

FAQ

What is Oxygen Equivalent given Organic Matter Present at Start of BOD?
The Oxygen Equivalent given Organic Matter Present at Start of BOD is defined as the oxidizable organic matter present in the sewage after t days from the start of oxidation and is represented as Lt = L*10^(-KD*t) or Oxygen Equivalent = Organic Matter at Start*10^(-Deoxygenation Constant*Time in days). Organic Matter at Start is the total organic matter present in the sewage at the start of the BOD reaction, Deoxygenation Constant is the value obtained after decomposing of oxygen in sewage & Time in days is the time calculated in days.
How to calculate Oxygen Equivalent given Organic Matter Present at Start of BOD?
The Oxygen Equivalent given Organic Matter Present at Start of BOD is defined as the oxidizable organic matter present in the sewage after t days from the start of oxidation is calculated using Oxygen Equivalent = Organic Matter at Start*10^(-Deoxygenation Constant*Time in days). To calculate Oxygen Equivalent given Organic Matter Present at Start of BOD, you need Organic Matter at Start (L), Deoxygenation Constant (KD) & Time in days (t). With our tool, you need to enter the respective value for Organic Matter at Start, Deoxygenation Constant & Time in days and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!