Partial pressure of water vapor in air Solution

STEP 0: Pre-Calculation Summary
Formula Used
Partial Pressure in air = Partial Pressure-((Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*Convective Mass Transfer Coefficient))
P∞ = Pw-((h*(T∞-Tw))/(hfg*kL))
This formula uses 7 Variables
Variables Used
Partial Pressure in air - Partial pressure in air of the water vapor is the pressure of water in the mixture of water and air.
Partial Pressure - Partial pressure of the water vapor at wet bulb temperature.
Convective Heat Transfer Coefficient - (Measured in Watt per Square Meter per Kelvin) - Convective Heat Transfer Coefficient is the heat transfer due to convection.
Air Temperature - Air temperature is the temperature of the air surrounding an individual and is typically measured in degrees Celsius (°C) or in Kelvin.
Wet Bulb Temperature - Wet Bulb Temperature is the temperature of the wet bulb and denoted by the symbol Tw.
Enthalpy of Evaporation - (Measured in Joule per Kilogram K) - Enthalpy of evaporation is the amount of energy (enthalpy) that must be added to a liquid substance to transform a quantity of that substance into a gas.
Convective Mass Transfer Coefficient - (Measured in Meter per Second) - Convective Mass Transfer Coefficient is a function of geometry of the system and the velocity and properties of the fluid similar to the heat transfer coefficient.
STEP 1: Convert Input(s) to Base Unit
Partial Pressure: 13 --> No Conversion Required
Convective Heat Transfer Coefficient: 0.5 Watt per Square Meter per Kelvin --> 0.5 Watt per Square Meter per Kelvin No Conversion Required
Air Temperature: 35 --> No Conversion Required
Wet Bulb Temperature: 14 --> No Conversion Required
Enthalpy of Evaporation: 90 Joule per Kilogram K --> 90 Joule per Kilogram K No Conversion Required
Convective Mass Transfer Coefficient: 0.0095 Meter per Second --> 0.0095 Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
P∞ = Pw-((h*(T∞-Tw))/(hfg*kL)) --> 13-((0.5*(35-14))/(90*0.0095))
Evaluating ... ...
P∞ = 0.719298245614034
STEP 3: Convert Result to Output's Unit
0.719298245614034 --> No Conversion Required
FINAL ANSWER
0.719298245614034 0.719298 <-- Partial Pressure in air
(Calculation completed in 00.004 seconds)

Credits

Created by Nishan Poojary
Shri Madhwa Vadiraja Institute of Technology and Management (SMVITM), Udupi
Nishan Poojary has created this Calculator and 500+ more calculators!
Verified by Rajat Vishwakarma
University Institute of Technology RGPV (UIT - RGPV), Bhopal
Rajat Vishwakarma has verified this Calculator and 400+ more calculators!

24 Humidification Calculators

Absolute humidity at inside temperature in dehumidification
Go Absolute Humidity (ti) = Absolute Humidity of Air(tg)-(((Liquid Phase Heat Transfer Coefficient*(Temperature at inner surface-Liquid layer temperature))-Gas Phase Heat Transfer Coefficient*(Bulk Gas Temperature-Temperature at inner surface))/(Gas Phase Mass Transfer Coefficient*Enthalpy of Evaporation))
Enthalpy of evaporation in dehumidification
Go Enthalpy of Evaporation = ((Liquid Phase Heat Transfer Coefficient*(Temperature at inner surface-Liquid layer temperature))-Gas Phase Heat Transfer Coefficient*(Bulk Gas Temperature-Temperature at inner surface))/(Gas Phase Mass Transfer Coefficient*(Absolute Humidity of Air(tg)-Absolute Humidity (ti)))
Liquid phase heat transfer coefficient in dehumidification
Go Liquid Phase Heat Transfer Coefficient = ((Gas Phase Heat Transfer Coefficient*(Bulk Gas Temperature-Temperature at inner surface))+Enthalpy of Evaporation*Gas Phase Mass Transfer Coefficient*(Absolute Humidity of Air(tg)-Absolute Humidity (ti)))/(Temperature at inner surface-Liquid layer temperature)
Gas phase heat transfer coefficient in dehumidification
Go Gas Phase Heat Transfer Coefficient = ((Liquid Phase Heat Transfer Coefficient*(Inside Temperature-Liquid layer temperature))-(Enthalpy of Evaporation*Gas Phase Mass Transfer Coefficient*(Absolute Humidity of Air(tg)-Absolute Humidity (ti))))/(Bulk Gas Temperature-Inside Temperature)
Gas phase mass transfer coefficient in dehumidification
Go Gas Phase Mass Transfer Coefficient = ((Liquid Phase Heat Transfer Coefficient*(Inside Temperature-Liquid layer temperature))-Gas Phase Heat Transfer Coefficient*(Bulk Gas Temperature-Inside Temperature))/(Enthalpy of Evaporation*(Absolute Humidity of Air(tg)-Absolute Humidity (ti)))
Bulk gas temperature in dehumidification
Go Bulk Gas Temperature = (((Liquid Phase Heat Transfer Coefficient*(Inside Temperature-Liquid layer temperature))-(Enthalpy of Evaporation*Gas Phase Mass Transfer Coefficient*(Absolute Humidity of Air(tg)-Absolute Humidity (ti))))/Gas Phase Heat Transfer Coefficient)+Inside Temperature
Liquid layer temperature in dehumidification
Go Liquid layer temperature = Inside Temperature-(((Gas Phase Heat Transfer Coefficient*(Bulk Gas Temperature-Inside Temperature))+Enthalpy of Evaporation*Gas Phase Mass Transfer Coefficient*(Absolute Humidity of Air(tg)-Absolute Humidity (ti)))/Liquid Phase Heat Transfer Coefficient)
Specific heat of air given gas constant
Go Specific Heat of Air = (((Enthalpy of Evaporation*(Partial Pressure-Partial Pressure in air))/(Gas constant*Density*(Air Temperature-Wet Bulb Temperature)*Mean Temperature*(Lewis Number^0.67))))
Gas constant of water vapor
Go Gas constant = (((Enthalpy of Evaporation*(Partial Pressure-Partial Pressure in air))/((Air Temperature-Wet Bulb Temperature)*Density*Specific Heat of Air*Mean Temperature*(Lewis Number^0.67))))
Temperature of air given gas constant of water
Go Air Temperature = (((Enthalpy of Evaporation*(Partial Pressure-Partial Pressure in air))/(Gas constant*Density*Specific Heat of Air*Mean Temperature*(Lewis Number^0.67))))+Wet Bulb Temperature
Wet bulb temperature given gas constant of water vapor
Go Wet Bulb Temperature = Air Temperature-((Enthalpy of Evaporation*(Partial Pressure-Partial Pressure in air))/(Gas constant*Density*Specific Heat of Air*Mean Temperature*(Lewis Number^0.67)))
Temperature of air during humidification
Go Air Temperature = (((0.622*Enthalpy of Evaporation)/(Specific Heat of Air*(Lewis Number^0.67)))*((Partial Pressure/Total Pressure)-(Partial Pressure in air/Total Pressure)))+Wet Bulb Temperature
Wet bulb temperature of humidification
Go Wet Bulb Temperature = Air Temperature-((0.622*Enthalpy of Evaporation)/(Specific Heat of Air*(Lewis Number^0.67)))*((Partial Pressure/Total Pressure)-(Partial Pressure in air/Total Pressure))
Absolute Humidity of Air at Final Equilibrium Air Temperature
Go Absolute Humidity of Air(ta) = (((Specific Heat of Air+(Absolute Humidity of Air(tg)*Specific Heat of Water Vapor))*(Bulk Gas Temperature-Temperature))/(Enthalpy of Evaporation))+Absolute Humidity of Air(tg)
Gas phase mass transfer coefficient given humidity
Go Gas Phase Mass Transfer Coefficient = (Mass Velocity of Air/Height)*ln((Absolute Humidity at Final Temperature-Humidity of air at entry)/(Absolute Humidity at Final Temperature-Humidity of air at exit))
Height of tower in adiabatic humidification
Go Height = (Mass Velocity of Air/Gas Phase Mass Transfer Coefficient)*ln((Absolute Humidity at Final Temperature-Humidity of air at entry)/(Absolute Humidity at Final Temperature-Humidity of air at exit))
Mass velocity of air per unit area
Go Mass Velocity of Air = (Height*Gas Phase Mass Transfer Coefficient)/ln((Absolute Humidity of Air(ta)-Humidity of Air at Entry(t))/(Absolute Humidity of Air(ta)-Humidity of air at exit))
Partial pressure of water vapor at wet bulb temperature
Go Partial Pressure = ((Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*Convective Mass Transfer Coefficient))+Partial Pressure in air
Convective mass transfer coefficient in humidification
Go Convective Mass Transfer Coefficient = (Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*(Partial Pressure-Partial Pressure in air))
Enthalpy of evaporation for water in humidification
Go Enthalpy of Evaporation = (Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Convective Mass Transfer Coefficient*(Partial Pressure-Partial Pressure in air))
Partial pressure of water vapor in air
Go Partial Pressure in air = Partial Pressure-((Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*Convective Mass Transfer Coefficient))
Heat transfer coefficient in humidification
Go Heat Transfer Coefficient = ((Partial Pressure-Partial Pressure in air)*(Enthalpy of Evaporation*Convective Mass Transfer Coefficient))/(Air Temperature-Wet Bulb Temperature)
Enthalpy of evaporation of water in humidification
Go Enthalpy of Evaporation = (Specific Heat of Air*(Lewis Number^0.67))/((Absolute Humidity of Air(tw)-Absolute Humidity of Air(atm))/(Air Temperature-Wet Bulb Temperature))
Specific heat of air during humidification
Go Specific Heat of Air = (Absolute Humidity of Air(tw)-Absolute Humidity of Air(atm))*Enthalpy of Evaporation/((Temperature-Air Temperature)*Lewis Number^0.67)

Partial pressure of water vapor in air Formula

Partial Pressure in air = Partial Pressure-((Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*Convective Mass Transfer Coefficient))
P∞ = Pw-((h*(T∞-Tw))/(hfg*kL))

What is humidification...?

Humidification is the process in which the moisture or water vapor or humidity is added to the air. Common equipment used in this process is a humidifier. Dehumidification as the term suggests, is the opposite of humidification since dehumidification means removing the moisture from the air. Common equipment used in this process is a dehumidifier.
Humidity is the presence of water vapor or moisture in the air, while relative humidity, on the other hand, is the comparison of the actual moisture or water vapor in the air vs. the total water vapor or moisture that the air can handle.



How to Calculate Partial pressure of water vapor in air?

Partial pressure of water vapor in air calculator uses Partial Pressure in air = Partial Pressure-((Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*Convective Mass Transfer Coefficient)) to calculate the Partial Pressure in air, Partial pressure of water vapor in air formula is defined as the partial pressure of the water vapor in the air as calculated from heat transfer coefficients. Partial Pressure in air is denoted by P∞ symbol.

How to calculate Partial pressure of water vapor in air using this online calculator? To use this online calculator for Partial pressure of water vapor in air, enter Partial Pressure (Pw), Convective Heat Transfer Coefficient (h), Air Temperature (T∞), Wet Bulb Temperature (Tw), Enthalpy of Evaporation (hfg) & Convective Mass Transfer Coefficient (kL) and hit the calculate button. Here is how the Partial pressure of water vapor in air calculation can be explained with given input values -> -0.815789 = 13-((0.5*(35-14))/(90*0.0095)).

FAQ

What is Partial pressure of water vapor in air?
Partial pressure of water vapor in air formula is defined as the partial pressure of the water vapor in the air as calculated from heat transfer coefficients and is represented as P∞ = Pw-((h*(T∞-Tw))/(hfg*kL)) or Partial Pressure in air = Partial Pressure-((Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*Convective Mass Transfer Coefficient)). Partial pressure of the water vapor at wet bulb temperature, Convective Heat Transfer Coefficient is the heat transfer due to convection, Air temperature is the temperature of the air surrounding an individual and is typically measured in degrees Celsius (°C) or in Kelvin, Wet Bulb Temperature is the temperature of the wet bulb and denoted by the symbol Tw, Enthalpy of evaporation is the amount of energy (enthalpy) that must be added to a liquid substance to transform a quantity of that substance into a gas & Convective Mass Transfer Coefficient is a function of geometry of the system and the velocity and properties of the fluid similar to the heat transfer coefficient.
How to calculate Partial pressure of water vapor in air?
Partial pressure of water vapor in air formula is defined as the partial pressure of the water vapor in the air as calculated from heat transfer coefficients is calculated using Partial Pressure in air = Partial Pressure-((Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*Convective Mass Transfer Coefficient)). To calculate Partial pressure of water vapor in air, you need Partial Pressure (Pw), Convective Heat Transfer Coefficient (h), Air Temperature (T∞), Wet Bulb Temperature (Tw), Enthalpy of Evaporation (hfg) & Convective Mass Transfer Coefficient (kL). With our tool, you need to enter the respective value for Partial Pressure, Convective Heat Transfer Coefficient, Air Temperature, Wet Bulb Temperature, Enthalpy of Evaporation & Convective Mass Transfer Coefficient and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.