Perimeter when Inlet Capacity for Flow Depth is up to 4.8 inches Solution

STEP 0: Pre-Calculation Summary
Formula Used
Perimeter of grate opening = Water Flow/(3*Depth of flow at Inlet^(3/2))
P = Q/(3*y^(3/2))
This formula uses 3 Variables
Variables Used
Perimeter of grate opening - (Measured in Meter) - Perimeter of grate opening is the length of the circumference of grate opening over which water may flow.
Water Flow - (Measured in Cubic Meter per Second) - Water Flow is rate of flow of water.
Depth of flow at Inlet - (Measured in Meter) - Depth of Flow at Inlet is the flow length at the inlet.
STEP 1: Convert Input(s) to Base Unit
Water Flow: 1.8 Cubic Meter per Second --> 1.8 Cubic Meter per Second No Conversion Required
Depth of flow at Inlet: 1.8 Foot --> 0.548640000002195 Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
P = Q/(3*y^(3/2)) --> 1.8/(3*0.548640000002195^(3/2))
Evaluating ... ...
P = 1.47645443506773
STEP 3: Convert Result to Output's Unit
1.47645443506773 Meter -->4.84401061371988 Foot (Check conversion ​here)
FINAL ANSWER
4.84401061371988 4.844011 Foot <-- Perimeter of grate opening
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Mridul Sharma
Indian Institute of Information Technology (IIIT), Bhopal
Mridul Sharma has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Rithik Agrawal
National Institute of Technology Karnataka (NITK), Surathkal
Rithik Agrawal has verified this Calculator and 400+ more calculators!

10+ Disposing of storm water Calculators

Depth of Flow at Inlet when Runoff Quantity with Full Gutter Flow is Giiven
​ Go Depth of flow at Inlet = ((Quantity of Runoff/(0.7*Length of Opening))^(2/3))-Depression in Curb Inlet
Depression in Curb Inlet given Runoff Quantity with Full Gutter flow
​ Go Depression in Curb Inlet = ((Quantity of Runoff/(0.7*Length of Opening))^(2/3))-Depth of flow at Inlet
Length of Opening given Runoff Quantity with Full Gutter Flow
​ Go Length of Opening = Quantity of Runoff/(0.7*(Depression in Curb Inlet+Depth of flow at Inlet)^(3/2))
Runoff Quantity with Full Gutter Flow
​ Go Quantity of Runoff = 0.7*Length of Opening*(Depression in Curb Inlet+Depth of flow at Inlet)^(3/2)
Depth of Flow given Inlet Capacity for Flow Depth more than 1ft 5in
​ Go Depth = ((Inlet Capacity/(0.6*Area))^2)*(1/(2*Acceleration due to Gravity))
Area of Opening given Inlet Capacity for Flow Depth more than 1ft 5in
​ Go Area = Inlet Capacity/(0.6*(2*Acceleration due to Gravity*Depth)^(1/2))
Inlet Capacity for Flow Depth more than 1ft 5in
​ Go Inlet Capacity = 0.6*Area*((2*Acceleration due to Gravity*Depth)^(1/2))
Depth of Flow at Inlet given Inlet Capacity for Flow Depth up to 4.8in
​ Go Depth of flow at Inlet = (Water Flow/(3*Perimeter of grate opening))^(2/3)
Perimeter when Inlet Capacity for Flow Depth is up to 4.8 inches
​ Go Perimeter of grate opening = Water Flow/(3*Depth of flow at Inlet^(3/2))
Inlet Capacity for Flow Depth
​ Go Water Flow = 3*Perimeter of grate opening*Depth of flow at Inlet^(3/2)

Perimeter when Inlet Capacity for Flow Depth is up to 4.8 inches Formula

Perimeter of grate opening = Water Flow/(3*Depth of flow at Inlet^(3/2))
P = Q/(3*y^(3/2))

What is an inlet structure?

Inlet structures are built to control the amount of water flowing into the pond at all times. An inlet structure may be built for a pond supplied through a feeder canal, for example by diverted stream water, a spring outside the pond, a well or a pumped water supply.

How to Calculate Perimeter when Inlet Capacity for Flow Depth is up to 4.8 inches?

Perimeter when Inlet Capacity for Flow Depth is up to 4.8 inches calculator uses Perimeter of grate opening = Water Flow/(3*Depth of flow at Inlet^(3/2)) to calculate the Perimeter of grate opening, The Perimeter when Inlet Capacity for Flow Depth is up to 4.8 inches formula calculates the perimeter of grate opening over which water may flow when flow depth is up to 4.8 inches. Perimeter of grate opening is denoted by P symbol.

How to calculate Perimeter when Inlet Capacity for Flow Depth is up to 4.8 inches using this online calculator? To use this online calculator for Perimeter when Inlet Capacity for Flow Depth is up to 4.8 inches, enter Water Flow (Q) & Depth of flow at Inlet (y) and hit the calculate button. Here is how the Perimeter when Inlet Capacity for Flow Depth is up to 4.8 inches calculation can be explained with given input values -> 15.89242 = 1.8/(3*0.548640000002195^(3/2)).

FAQ

What is Perimeter when Inlet Capacity for Flow Depth is up to 4.8 inches?
The Perimeter when Inlet Capacity for Flow Depth is up to 4.8 inches formula calculates the perimeter of grate opening over which water may flow when flow depth is up to 4.8 inches and is represented as P = Q/(3*y^(3/2)) or Perimeter of grate opening = Water Flow/(3*Depth of flow at Inlet^(3/2)). Water Flow is rate of flow of water & Depth of Flow at Inlet is the flow length at the inlet.
How to calculate Perimeter when Inlet Capacity for Flow Depth is up to 4.8 inches?
The Perimeter when Inlet Capacity for Flow Depth is up to 4.8 inches formula calculates the perimeter of grate opening over which water may flow when flow depth is up to 4.8 inches is calculated using Perimeter of grate opening = Water Flow/(3*Depth of flow at Inlet^(3/2)). To calculate Perimeter when Inlet Capacity for Flow Depth is up to 4.8 inches, you need Water Flow (Q) & Depth of flow at Inlet (y). With our tool, you need to enter the respective value for Water Flow & Depth of flow at Inlet and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!