Period of Occurrence of Fire given Quantity of Water Solution

STEP 0: Pre-Calculation Summary
Formula Used
Time period = ((Quantity of Water*(((Time Duration/60)+12)^(0.757))/4360)^(1/0.275))*31556952
T = ((Qw*(((td/60)+12)^(0.757))/4360)^(1/0.275))*31556952
This formula uses 3 Variables
Variables Used
Time period - (Measured in Second) - Time period is the time period of occurrence of fire .
Quantity of Water - (Measured in Liter per minute) - The Quantity of Water is the amount of water required to extinguish a fire. It is the discharge in liters per minute.
Time Duration - (Measured in Second) - Time Duration is the time duration of fire.
STEP 1: Convert Input(s) to Base Unit
Quantity of Water: 759.265 Liter per minute --> 759.265 Liter per minute No Conversion Required
Time Duration: 3 Minute --> 180 Second (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
T = ((Qw*(((td/60)+12)^(0.757))/4360)^(1/0.275))*31556952 --> ((759.265*(((180/60)+12)^(0.757))/4360)^(1/0.275))*31556952
Evaluating ... ...
T = 94670562.2029695
STEP 3: Convert Result to Output's Unit
94670562.2029695 Second -->2.99999068994273 Year (Check conversion ​here)
FINAL ANSWER
2.99999068994273 2.999991 Year <-- Time period
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

11 Fire Demand Calculators

Quantity of Water by National Board of Fire Underwriters
​ Go Quantity of Water in Liters Per Minute = 4637*sqrt(Population in thousands)*(1-(0.01*sqrt(Population in thousands)))
Period of Occurrence of Fire given Quantity of Water
​ Go Time period = ((Quantity of Water*(((Time Duration/60)+12)^(0.757))/4360)^(1/0.275))*31556952
Quantity of Water given Duration of Fire
​ Go Quantity of Water = (4360*(Time period/31556952)^(0.275))/(((Time Duration/60)+12)^(0.757))
Quantity of Water by Buston's Formula
​ Go Quantity of Water in Liters Per Minute = (5663*sqrt(Population in thousands))
Quantity of Water by Kuichling's Formula
​ Go Quantity of Water in Liters Per Minute = 3182*sqrt(Population in thousands)
Number of Simultaneous Fire Stream
​ Go Number of Fire streams = 2.8*sqrt(Population in thousands)
Population by Freeman's Formula given Quantity of Water
​ Go Population in thousands = 5*((Quantity of Water in Liters Per Minute/1136)-10)
Quantity of Water by Freeman's Formula
​ Go Quantity of Water in Liters Per Minute = 1136*((Population in thousands/5)+10)
Population by Kuichling's Formula given Quantity of Water
​ Go Population in thousands = (Quantity of Water in Liters Per Minute/3182)^2
Population by Buston's Formula given Quantity of Water
​ Go Population in thousands = (Quantity of Water in Liters Per Minute/5663)^2
Population given Number of Simultaneous Fire Stream
​ Go Population in thousands = (Number of Fire streams/2.8)^2

Period of Occurrence of Fire given Quantity of Water Formula

Time period = ((Quantity of Water*(((Time Duration/60)+12)^(0.757))/4360)^(1/0.275))*31556952
T = ((Qw*(((td/60)+12)^(0.757))/4360)^(1/0.275))*31556952

What is Fire Demand ?

Fire demand is the amount of water required to extinguish fire.The water required for fire fighting in a given area. Although the actual amount of water used in a year is small for fire fighting. But the rate of use is large.

How to Calculate Period of Occurrence of Fire given Quantity of Water?

Period of Occurrence of Fire given Quantity of Water calculator uses Time period = ((Quantity of Water*(((Time Duration/60)+12)^(0.757))/4360)^(1/0.275))*31556952 to calculate the Time period, The Period of Occurrence of Fire given Quantity of Water formula is defined as it calculates the period of occurrence of fire when we have prior information of other parameters used. Time period is denoted by T symbol.

How to calculate Period of Occurrence of Fire given Quantity of Water using this online calculator? To use this online calculator for Period of Occurrence of Fire given Quantity of Water, enter Quantity of Water (Qw) & Time Duration (td) and hit the calculate button. Here is how the Period of Occurrence of Fire given Quantity of Water calculation can be explained with given input values -> 9.5E-8 = ((0.0126544166666667*(((180/60)+12)^(0.757))/4360)^(1/0.275))*31556952.

FAQ

What is Period of Occurrence of Fire given Quantity of Water?
The Period of Occurrence of Fire given Quantity of Water formula is defined as it calculates the period of occurrence of fire when we have prior information of other parameters used and is represented as T = ((Qw*(((td/60)+12)^(0.757))/4360)^(1/0.275))*31556952 or Time period = ((Quantity of Water*(((Time Duration/60)+12)^(0.757))/4360)^(1/0.275))*31556952. The Quantity of Water is the amount of water required to extinguish a fire. It is the discharge in liters per minute & Time Duration is the time duration of fire.
How to calculate Period of Occurrence of Fire given Quantity of Water?
The Period of Occurrence of Fire given Quantity of Water formula is defined as it calculates the period of occurrence of fire when we have prior information of other parameters used is calculated using Time period = ((Quantity of Water*(((Time Duration/60)+12)^(0.757))/4360)^(1/0.275))*31556952. To calculate Period of Occurrence of Fire given Quantity of Water, you need Quantity of Water (Qw) & Time Duration (td). With our tool, you need to enter the respective value for Quantity of Water & Time Duration and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!