Reoxygenation Coefficient at 20 degree Celsius Solution

STEP 0: Pre-Calculation Summary
Formula Used
Reoxygenation coefficient at temperature 20 = Reoxygenation coefficient/((1.016)^(Temperature-20))
KR(20) = KR/((1.016)^(T-20))
This formula uses 3 Variables
Variables Used
Reoxygenation coefficient at temperature 20 - (Measured in 1 Per Second) - Reoxygenation coefficient at temperature 20 is the BOD rate constant at 20°C temperature.
Reoxygenation coefficient - (Measured in 1 Per Second) - Reoxygenation coefficient implies the higher the flow velocity, the higher the re-oxygenation coefficient.
Temperature - (Measured in Kelvin) - Temperature is the degree or intensity of heat present in a substance or object.
STEP 1: Convert Input(s) to Base Unit
Reoxygenation coefficient: 0.1 1 Per Day --> 1.15740740740741E-06 1 Per Second (Check conversion here)
Temperature: 85 Kelvin --> 85 Kelvin No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
KR(20) = KR/((1.016)^(T-20)) --> 1.15740740740741E-06/((1.016)^(85-20))
Evaluating ... ...
KR(20) = 4.12472729794933E-07
STEP 3: Convert Result to Output's Unit
4.12472729794933E-07 1 Per Second -->0.0356376438542822 1 Per Day (Check conversion here)
FINAL ANSWER
0.0356376438542822 0.035638 1 Per Day <-- Reoxygenation coefficient at temperature 20
(Calculation completed in 00.006 seconds)

Credits

Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 600+ more calculators!

6 Reoxygenation Coefficient Calculators

Reoxygenation Coefficient given Critical Oxygen Deficit
Go Reoxygenation coefficient = Deoxygenation Constant*Oxygen Equivalent*(10^(-Deoxygenation Constant*Critical time))/Critical oxygen deficit
Temperature given Reoxygenation Coefficient at T degree Celsius
Go Temperature = log((Reoxygenation coefficient/Reoxygenation coefficient at temperature 20),1.016)+20
Reoxygenation Coefficients
Go Reoxygenation coefficient = Reoxygenation coefficient at Temperature 20*(1.016)^(Temperature-20)
Stream Depth given Reoxygenation Coefficient
Go Depth Of stream = (3.9*sqrt(Velocity)/Reoxygenation coefficient)^(1/1.5)
Reoxygenation Coefficient at 20 degree Celsius
Go Reoxygenation coefficient at temperature 20 = Reoxygenation coefficient/((1.016)^(Temperature-20))
Reoxygenation Coefficient given Self Purification Constant
Go Reoxygenation coefficient = Deoxygenation Constant*Self purification constant

Reoxygenation Coefficient at 20 degree Celsius Formula

Reoxygenation coefficient at temperature 20 = Reoxygenation coefficient/((1.016)^(Temperature-20))
KR(20) = KR/((1.016)^(T-20))

What is BOD?

BOD is a measure of the amount of oxygen required to remove waste organic matter from water in the process of decomposition by aerobic bacteria.

How to Calculate Reoxygenation Coefficient at 20 degree Celsius?

Reoxygenation Coefficient at 20 degree Celsius calculator uses Reoxygenation coefficient at temperature 20 = Reoxygenation coefficient/((1.016)^(Temperature-20)) to calculate the Reoxygenation coefficient at temperature 20, The Reoxygenation Coefficient at 20 degree Celsius is the value of coefficient at 20°C temperature. Reoxygenation coefficient is the process of adding oxygen to the body of water. Reoxygenation coefficient at temperature 20 is denoted by KR(20) symbol.

How to calculate Reoxygenation Coefficient at 20 degree Celsius using this online calculator? To use this online calculator for Reoxygenation Coefficient at 20 degree Celsius, enter Reoxygenation coefficient (KR) & Temperature (T) and hit the calculate button. Here is how the Reoxygenation Coefficient at 20 degree Celsius calculation can be explained with given input values -> 3079.092 = 1.15740740740741E-06/((1.016)^(85-20)).

FAQ

What is Reoxygenation Coefficient at 20 degree Celsius?
The Reoxygenation Coefficient at 20 degree Celsius is the value of coefficient at 20°C temperature. Reoxygenation coefficient is the process of adding oxygen to the body of water and is represented as KR(20) = KR/((1.016)^(T-20)) or Reoxygenation coefficient at temperature 20 = Reoxygenation coefficient/((1.016)^(Temperature-20)). Reoxygenation coefficient implies the higher the flow velocity, the higher the re-oxygenation coefficient & Temperature is the degree or intensity of heat present in a substance or object.
How to calculate Reoxygenation Coefficient at 20 degree Celsius?
The Reoxygenation Coefficient at 20 degree Celsius is the value of coefficient at 20°C temperature. Reoxygenation coefficient is the process of adding oxygen to the body of water is calculated using Reoxygenation coefficient at temperature 20 = Reoxygenation coefficient/((1.016)^(Temperature-20)). To calculate Reoxygenation Coefficient at 20 degree Celsius, you need Reoxygenation coefficient (KR) & Temperature (T). With our tool, you need to enter the respective value for Reoxygenation coefficient & Temperature and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!