Formula Used
Self purification constant = Oxygen Equivalent/10^(log10(Critical oxygen deficit)+(Deoxygenation Constant*Critical time))
f = Lt/10^(log10(Dc)+(KD*tc))
This formula uses 1 Functions, 5 Variables
Functions Used
log10 - The common logarithm, also known as the base-10 logarithm or the decimal logarithm, is a mathematical function that is the inverse of the exponential function., log10(Number)
Variables Used
Self purification constant - Self purification constant is the ratio of reoxygenation constant to deoxygenation constant.
Oxygen Equivalent - (Measured in Kilogram per Cubic Meter) - Oxygen Equivalent is the oxidisable organic matter present in sewage.
Critical oxygen deficit - Critical oxygen deficit is the condition where the deoxygenation rate exceeds the reoxygenation rate.
Deoxygenation Constant - (Measured in 1 Per Second) - Deoxygenation Constant is the value obtained after decomposing of oxygen in sewage.
Critical time - (Measured in Second) - Critical time is the time after which the minimum dissolved oxygen occurs can be found by differentiating the equation.
STEP 1: Convert Input(s) to Base Unit
Oxygen Equivalent: 0.21 Milligram per Liter --> 0.00021 Kilogram per Cubic Meter (Check conversion here)
Critical oxygen deficit: 6 --> No Conversion Required
Deoxygenation Constant: 0.23 1 Per Day --> 2.66203703703704E-06 1 Per Second (Check conversion here)
Critical time: 0.5 Day --> 43200 Second (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
f = Lt/10^(log10(Dc)+(KD*tc)) --> 0.00021/10^(log10(6)+(2.66203703703704E-06*43200))
Evaluating ... ...
f = 2.68576521276637E-05
STEP 3: Convert Result to Output's Unit
2.68576521276637E-05 --> No Conversion Required
FINAL ANSWER
2.68576521276637E-05 2.7E-5 <-- Self purification constant
(Calculation completed in 00.020 seconds)

Credits

Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 600+ more calculators!

3 Self Purification Constant Calculators

Self Purification Constant given Log value of Critical Oxygen Deficit
Go Self purification constant = Oxygen Equivalent/10^(log10(Critical oxygen deficit)+(Deoxygenation Constant*Critical time))
Self Purification Constant given Critical Oxygen Deficit
Go Self purification constant = Oxygen Equivalent*10^(-Deoxygenation Constant*Critical time)/Critical oxygen deficit
Self Purification Constant
Go Self purification constant = Reoxygenation coefficient/Deoxygenation Constant

Self Purification Constant given Log value of Critical Oxygen Deficit Formula

Self purification constant = Oxygen Equivalent/10^(log10(Critical oxygen deficit)+(Deoxygenation Constant*Critical time))
f = Lt/10^(log10(Dc)+(KD*tc))

What is critical oxygen deficit?

The Critical oxygen deficit is the condition where the deoxygenation rate exceeds the reoxygenation rate.

How to Calculate Self Purification Constant given Log value of Critical Oxygen Deficit?

Self Purification Constant given Log value of Critical Oxygen Deficit calculator uses Self purification constant = Oxygen Equivalent/10^(log10(Critical oxygen deficit)+(Deoxygenation Constant*Critical time)) to calculate the Self purification constant, Self Purification Constant given Log value of Critical Oxygen Deficit is ratio of reoxygenation constant to deoxygenation constant (or R'/K') and it is equal to 0.50 to 5.0. Self purification constant is denoted by f symbol.

How to calculate Self Purification Constant given Log value of Critical Oxygen Deficit using this online calculator? To use this online calculator for Self Purification Constant given Log value of Critical Oxygen Deficit, enter Oxygen Equivalent (Lt), Critical oxygen deficit (Dc), Deoxygenation Constant (KD) & Critical time (tc) and hit the calculate button. Here is how the Self Purification Constant given Log value of Critical Oxygen Deficit calculation can be explained with given input values -> 2.7E-5 = 0.00021/10^(log10(6)+(2.66203703703704E-06*43200)).

FAQ

What is Self Purification Constant given Log value of Critical Oxygen Deficit?
Self Purification Constant given Log value of Critical Oxygen Deficit is ratio of reoxygenation constant to deoxygenation constant (or R'/K') and it is equal to 0.50 to 5.0 and is represented as f = Lt/10^(log10(Dc)+(KD*tc)) or Self purification constant = Oxygen Equivalent/10^(log10(Critical oxygen deficit)+(Deoxygenation Constant*Critical time)). Oxygen Equivalent is the oxidisable organic matter present in sewage, Critical oxygen deficit is the condition where the deoxygenation rate exceeds the reoxygenation rate, Deoxygenation Constant is the value obtained after decomposing of oxygen in sewage & Critical time is the time after which the minimum dissolved oxygen occurs can be found by differentiating the equation.
How to calculate Self Purification Constant given Log value of Critical Oxygen Deficit?
Self Purification Constant given Log value of Critical Oxygen Deficit is ratio of reoxygenation constant to deoxygenation constant (or R'/K') and it is equal to 0.50 to 5.0 is calculated using Self purification constant = Oxygen Equivalent/10^(log10(Critical oxygen deficit)+(Deoxygenation Constant*Critical time)). To calculate Self Purification Constant given Log value of Critical Oxygen Deficit, you need Oxygen Equivalent (Lt), Critical oxygen deficit (Dc), Deoxygenation Constant (KD) & Critical time (tc). With our tool, you need to enter the respective value for Oxygen Equivalent, Critical oxygen deficit, Deoxygenation Constant & Critical time and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Self purification constant?
In this formula, Self purification constant uses Oxygen Equivalent, Critical oxygen deficit, Deoxygenation Constant & Critical time. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Self purification constant = Reoxygenation coefficient/Deoxygenation Constant
  • Self purification constant = Oxygen Equivalent*10^(-Deoxygenation Constant*Critical time)/Critical oxygen deficit
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!