Sensible Cooling load due to Equipment Solution

STEP 0: Pre-Calculation Summary
Formula Used
Sensible Cooling Load = Total Cooling Load/Latent Factor
Qper hour = QT/LF
This formula uses 3 Variables
Variables Used
Sensible Cooling Load - (Measured in Watt) - Sensible Cooling Load is the heat added or removed from conditioned space by means of roof, ceiling, floor or windows.
Total Cooling Load - (Measured in Watt) - Total Cooling Load is heat transferred through the building envelope and heat generated by occupants, equipment, and lights.
Latent Factor - The Latent Factor is approximated latent cooling load.
STEP 1: Convert Input(s) to Base Unit
Total Cooling Load: 14.2 Btu (th) per Hour --> 4.15882499989918 Watt (Check conversion here)
Latent Factor: 1.25 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Qper hour = QT/LF --> 4.15882499989918/1.25
Evaluating ... ...
Qper hour = 3.32705999991934
STEP 3: Convert Result to Output's Unit
3.32705999991934 Watt -->11.36 Btu (th) per Hour (Check conversion here)
FINAL ANSWER
11.36 Btu (th) per Hour <-- Sensible Cooling Load
(Calculation completed in 00.004 seconds)

Credits

Created by Rudrani Tidke
Cummins College of Engineering for Women (CCEW), Pune
Rudrani Tidke has created this Calculator and 100+ more calculators!
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

6 Sensible Cooling Loads Calculators

Sensible Cooling load from ventilation air
Go Sensible cooling loads from ventilation air = 1.1*Air ventilation rate in Cubic foot per minute*Temperature change between Outdoor and Inside air
Sensible Heat Gain per people using Sensible Heat Gain from people
Go Sensible Heat Gains per person = Sensible Heat Gain from people/(Number of people*Cooling Load Factor for people)
Sensible Heat Gain from people
Go Sensible Heat Gain from people = Sensible Heat Gains per person*Number of people*Cooling Load Factor for people
Sensible Cooling Load Heat Gain through Structure
Go Sensible Cooling Load = Overall Heat Transfer Coefficient*Surface Area*Cooling Load Temperature Difference
Sensible Cooling Load due to infiltrating air
Go Sensible Cooling Load = 1.1*Air Infiltration Rate into Room*Temperature change between Outdoor and Inside air
Sensible Cooling load due to Equipment
Go Sensible Cooling Load = Total Cooling Load/Latent Factor

Sensible Cooling load due to Equipment Formula

Sensible Cooling Load = Total Cooling Load/Latent Factor
Qper hour = QT/LF

What is meant by cooling load?

The cooling load is the amount of heat energy that would need to be removed from a space (cooling) to maintain the temperature in an acceptable range.

How to Calculate Sensible Cooling load due to Equipment?

Sensible Cooling load due to Equipment calculator uses Sensible Cooling Load = Total Cooling Load/Latent Factor to calculate the Sensible Cooling Load, The Sensible Cooling load due to Equipment formula is defined as the energy that alters the mean radiant temperature (MRT) and air temperature that you can feel. Sensible Cooling Load is denoted by Qper hour symbol.

How to calculate Sensible Cooling load due to Equipment using this online calculator? To use this online calculator for Sensible Cooling load due to Equipment, enter Total Cooling Load (QT) & Latent Factor (LF) and hit the calculate button. Here is how the Sensible Cooling load due to Equipment calculation can be explained with given input values -> 38.78788 = 4.15882499989918/1.25.

FAQ

What is Sensible Cooling load due to Equipment?
The Sensible Cooling load due to Equipment formula is defined as the energy that alters the mean radiant temperature (MRT) and air temperature that you can feel and is represented as Qper hour = QT/LF or Sensible Cooling Load = Total Cooling Load/Latent Factor. Total Cooling Load is heat transferred through the building envelope and heat generated by occupants, equipment, and lights & The Latent Factor is approximated latent cooling load.
How to calculate Sensible Cooling load due to Equipment?
The Sensible Cooling load due to Equipment formula is defined as the energy that alters the mean radiant temperature (MRT) and air temperature that you can feel is calculated using Sensible Cooling Load = Total Cooling Load/Latent Factor. To calculate Sensible Cooling load due to Equipment, you need Total Cooling Load (QT) & Latent Factor (LF). With our tool, you need to enter the respective value for Total Cooling Load & Latent Factor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Sensible Cooling Load?
In this formula, Sensible Cooling Load uses Total Cooling Load & Latent Factor. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Sensible Cooling Load = Overall Heat Transfer Coefficient*Surface Area*Cooling Load Temperature Difference
  • Sensible Cooling Load = 1.1*Air Infiltration Rate into Room*Temperature change between Outdoor and Inside air
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!