Specific Capacity given Aquifer Loss Solution

STEP 0: Pre-Calculation Summary
Formula Used
Specific Capacity = (Discharge/(Head Loss in well+Aquifer loss))
Sc = (Q/(CQn+BQ))
This formula uses 4 Variables
Variables Used
Specific Capacity - (Measured in Square Meter per Second) - Specific Capacity is the quantity that which a water well can produce per unit of drawdown.
Discharge - (Measured in Cubic Meter per Second) - Discharge is the rate of flow of a liquid.
Head Loss in well - (Measured in Meter) - The Head Loss in well is essentially the difference between the head of the aquifer immediately outside and in the well a head inside because of all these losses.
Aquifer loss - (Measured in Meter) - Aquifer loss is product of discharge and aquifer loss coefficient.
STEP 1: Convert Input(s) to Base Unit
Discharge: 1.01 Cubic Meter per Second --> 1.01 Cubic Meter per Second No Conversion Required
Head Loss in well: 0.091 Meter --> 0.091 Meter No Conversion Required
Aquifer loss: 27.13 Meter --> 27.13 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Sc = (Q/(CQn+BQ)) --> (1.01/(0.091+27.13))
Evaluating ... ...
Sc = 0.0371037066970354
STEP 3: Convert Result to Output's Unit
0.0371037066970354 Square Meter per Second --> No Conversion Required
FINAL ANSWER
0.0371037066970354 0.037104 Square Meter per Second <-- Specific Capacity
(Calculation completed in 00.020 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

7 Specific Capacity of Well Calculators

Aquifer Loss Coefficient given Specific Capacity
Go Aquifer Loss Coefficient = ((Discharge/Specific Capacity)-Head Loss in well)/Discharge
Specific Capacity given Aquifer Loss
Go Specific Capacity = (Discharge/(Head Loss in well+Aquifer loss))
Well Discharge given Specific Capacity
Go Discharge = Specific Capacity*(Head Loss in well+Aquifer loss)
Aquifer Loss given Specific Capacity
Go Aquifer loss = (Discharge/Specific Capacity)-Head Loss in well
Drawdown given Specific Capacity of Well
Go Total Drawdown in Well = Discharge/Specific Capacity
Discharge given Specific Capacity
Go Discharge = Specific Capacity*Total Drawdown in Well
Specific Capacity given Drawdown
Go Specific Capacity = Discharge/Total Drawdown in Well

Specific Capacity given Aquifer Loss Formula

Specific Capacity = (Discharge/(Head Loss in well+Aquifer loss))
Sc = (Q/(CQn+BQ))

What is Specific Capacity?

Specific capacity is a quantity that which a water well can produce per unit of drawdown. It is normally obtained from a step drawdown test.

How to Calculate Specific Capacity given Aquifer Loss?

Specific Capacity given Aquifer Loss calculator uses Specific Capacity = (Discharge/(Head Loss in well+Aquifer loss)) to calculate the Specific Capacity, The Specific Capacity given Aquifer Loss is defined as the value of specific capacity when we have prior information of other parameters used. Specific Capacity is denoted by Sc symbol.

How to calculate Specific Capacity given Aquifer Loss using this online calculator? To use this online calculator for Specific Capacity given Aquifer Loss, enter Discharge (Q), Head Loss in well (CQn) & Aquifer loss (BQ) and hit the calculate button. Here is how the Specific Capacity given Aquifer Loss calculation can be explained with given input values -> 0.035289 = (1.01/(0.091+27.13)).

FAQ

What is Specific Capacity given Aquifer Loss?
The Specific Capacity given Aquifer Loss is defined as the value of specific capacity when we have prior information of other parameters used and is represented as Sc = (Q/(CQn+BQ)) or Specific Capacity = (Discharge/(Head Loss in well+Aquifer loss)). Discharge is the rate of flow of a liquid, The Head Loss in well is essentially the difference between the head of the aquifer immediately outside and in the well a head inside because of all these losses & Aquifer loss is product of discharge and aquifer loss coefficient.
How to calculate Specific Capacity given Aquifer Loss?
The Specific Capacity given Aquifer Loss is defined as the value of specific capacity when we have prior information of other parameters used is calculated using Specific Capacity = (Discharge/(Head Loss in well+Aquifer loss)). To calculate Specific Capacity given Aquifer Loss, you need Discharge (Q), Head Loss in well (CQn) & Aquifer loss (BQ). With our tool, you need to enter the respective value for Discharge, Head Loss in well & Aquifer loss and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Specific Capacity?
In this formula, Specific Capacity uses Discharge, Head Loss in well & Aquifer loss. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Specific Capacity = Discharge/Total Drawdown in Well
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!