How to Calculate Strip Width when Total Static Design Moment is Given?
Strip Width when Total Static Design Moment is Given calculator uses Span Perpendicular to L1 =(8*Total Static Design Moment in a Strip)/(Uniform Design Load*Clear Span in Direction of Moments ) to calculate the Span Perpendicular to L1 , The Strip Width when Total Static Design Moment is Given formula is defined by the parameters of Total Static Design Moment Mo, Uniform Design Load w and clear span in
direction moments are being determined. Span Perpendicular to L1 and is denoted by l2 symbol.
How to calculate Strip Width when Total Static Design Moment is Given using this online calculator? To use this online calculator for Strip Width when Total Static Design Moment is Given, enter Total Static Design Moment in a Strip (Mo), Uniform Design Load (w) and Clear Span in Direction of Moments (ln) and hit the calculate button. Here is how the Strip Width when Total Static Design Moment is Given calculation can be explained with given input values -> 0.04 = (8*1000)/(20000*10).