Surface Area of Circular Settling Tank Solution

STEP 0: Pre-Calculation Summary
Formula Used
Surface Area = (Peak Discharge/Surface Loading Rate)
SA = (Qp/R)
This formula uses 3 Variables
Variables Used
Surface Area - (Measured in Square Meter) - The Surface Area of a three-dimensional shape is the sum of all of the surface areas of each of the sides.
Peak Discharge - (Measured in Cubic Meter per Second) - Peak Discharge is the maximum volume flow rate passing a particular location during an event.
Surface Loading Rate - (Measured in Meter per Second) - Surface Loading Rate is the number of gallons of wastewater passing over 1 ft2 of tank per day.
STEP 1: Convert Input(s) to Base Unit
Peak Discharge: 4 Cubic Meter per Second --> 4 Cubic Meter per Second No Conversion Required
Surface Loading Rate: 0.22 Meter per Second --> 0.22 Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
SA = (Qp/R) --> (4/0.22)
Evaluating ... ...
SA = 18.1818181818182
STEP 3: Convert Result to Output's Unit
18.1818181818182 Square Meter --> No Conversion Required
FINAL ANSWER
18.1818181818182 18.18182 Square Meter <-- Surface Area
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

15 Design of a Circular Settling Tank Calculators

Mixed Liquor Suspended Solids in Aeration Tank using Maximum Solids
​ Go MLSS = (Maximum Solids in Aeriation Tank/((Peak Discharge+Return Activated Sludge)*8.34))
Design Surface Loading Rate given Surface Area of Circular Settling Tank
​ Go Surface Loading Rate = (Peak Discharge/Surface Area)
Average Daily Load using Peak Discharge in Circular Settling Tanks
​ Go Average Daily Load = (Peak Discharge/Peaking factor)
Peaking Factor using Peak Discharge in Circular Settling Tanks
​ Go Peaking factor = (Peak Discharge/Average Daily Load)
Peak Discharge given Surface Area of Circular Settling Tank
​ Go Peak Discharge = (Surface Area*Surface Loading Rate)
Surface Area of Circular Settling Tank
​ Go Surface Area = (Peak Discharge/Surface Loading Rate)
Solids Processed given Actual Solid Loading Rate
​ Go Solid Processed = (Solid Loading Rate*Surface Area)
Assumed Solid Loading Rate of Circular Settling Tanks
​ Go Solid Loading Rate = (Maximum Solids/Surface Area)
Peak Discharge in Circular Settling Tanks
​ Go Peak Discharge = Average Daily Load*Peaking factor
Total Settling Tank Surface Area given Actual Solid Loading Rate
​ Go Surface Area = Solid Processed/Solid Loading Rate
Actual Solid Loading Rate of Circular Settling Tanks
​ Go Solid Loading Rate = Solid Processed/Surface Area
Maximum Solids given Solid Loading Rate
​ Go Maximum Solids = Surface Area*Solid Loading Rate
Surface Area given Solid Loading Rate
​ Go Surface Area = Maximum Solids/Solid Loading Rate
Influent Flow Rate given Return Activated Sludge Flow Rate
​ Go Average Daily Influent Flow Rate = (Return Activated Sludge/1.25)
Return Activated Sludge Flow Rate
​ Go Return Activated Sludge = 1.25*Average Daily Influent Flow Rate

Surface Area of Circular Settling Tank Formula

Surface Area = (Peak Discharge/Surface Loading Rate)
SA = (Qp/R)

What is surface loading rate ?

Surface loading rate is defined as the volume of water flow per unit of time divided by the surface area of the settling basin. It is usually expressed as a velocity in feet per second.

How to Calculate Surface Area of Circular Settling Tank?

Surface Area of Circular Settling Tank calculator uses Surface Area = (Peak Discharge/Surface Loading Rate) to calculate the Surface Area, The Surface Area of Circular Settling Tank is define as the the sum of the areas of all faces (or surfaces) on a 3D shape.It is calculated when we have prior information of loading rate and peak discharge. Surface Area is denoted by SA symbol.

How to calculate Surface Area of Circular Settling Tank using this online calculator? To use this online calculator for Surface Area of Circular Settling Tank, enter Peak Discharge (Qp) & Surface Loading Rate (R) and hit the calculate button. Here is how the Surface Area of Circular Settling Tank calculation can be explained with given input values -> 0.8 = (4/0.22).

FAQ

What is Surface Area of Circular Settling Tank?
The Surface Area of Circular Settling Tank is define as the the sum of the areas of all faces (or surfaces) on a 3D shape.It is calculated when we have prior information of loading rate and peak discharge and is represented as SA = (Qp/R) or Surface Area = (Peak Discharge/Surface Loading Rate). Peak Discharge is the maximum volume flow rate passing a particular location during an event & Surface Loading Rate is the number of gallons of wastewater passing over 1 ft2 of tank per day.
How to calculate Surface Area of Circular Settling Tank?
The Surface Area of Circular Settling Tank is define as the the sum of the areas of all faces (or surfaces) on a 3D shape.It is calculated when we have prior information of loading rate and peak discharge is calculated using Surface Area = (Peak Discharge/Surface Loading Rate). To calculate Surface Area of Circular Settling Tank, you need Peak Discharge (Qp) & Surface Loading Rate (R). With our tool, you need to enter the respective value for Peak Discharge & Surface Loading Rate and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Surface Area?
In this formula, Surface Area uses Peak Discharge & Surface Loading Rate. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Surface Area = Maximum Solids/Solid Loading Rate
  • Surface Area = Solid Processed/Solid Loading Rate
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!