Time Constant for Heating Process Solution

STEP 0: Pre-Calculation Summary
Formula Used
Time Constant = (Density*Volume)/(Mass Flow Rate)
𝜏 = (ρ*V)/()
This formula uses 4 Variables
Variables Used
Time Constant - (Measured in Second) - Time Constant (𝜏) is the time required by the response to reach 63.2% of its ultimate value. If 𝜏 is high that means system will response fast.
Density - (Measured in Kilogram per Cubic Meter) - Density of a material shows the denseness of that material in a specific given area. This is taken as mass per unit volume of a given object.
Volume - (Measured in Cubic Meter) - Volume is the amount of space that a substance or object occupies or that is enclosed within a container.
Mass Flow Rate - (Measured in Kilogram per Second) - Mass flow rate is the mass of a substance that passes per unit of time. Its unit is kilogram per second in SI units.
STEP 1: Convert Input(s) to Base Unit
Density: 997.3 Kilogram per Cubic Meter --> 997.3 Kilogram per Cubic Meter No Conversion Required
Volume: 63 Cubic Meter --> 63 Cubic Meter No Conversion Required
Mass Flow Rate: 101.5 Kilogram per Second --> 101.5 Kilogram per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
𝜏 = (ρ*V)/(ṁ) --> (997.3*63)/(101.5)
Evaluating ... ...
𝜏 = 619.013793103448
STEP 3: Convert Result to Output's Unit
619.013793103448 Second --> No Conversion Required
FINAL ANSWER
619.013793103448 619.0138 Second <-- Time Constant
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Ayush gupta
University School of Chemical Technology-USCT (GGSIPU), New Delhi
Ayush gupta has created this Calculator and 300+ more calculators!
Verifier Image
Verified by Prerana Bakli
University of Hawaiʻi at Mānoa (UH Manoa), Hawaii, USA
Prerana Bakli has verified this Calculator and 1600+ more calculators!

5 Process Dynamics and Control Calculators

Time Period of Oscillations using Time Constant and Damping Factor
​ Go Time Period of Oscillations = (2*pi*Time Constant)/(sqrt(1-((Damping Factor)^2)))
Time Constant for Mercury in Glass Thermometer
​ Go Time Constant = ((Mass*Specific Heat)/(Heat Transfer Coefficient*Area))
Time Constant for Heating Process
​ Go Time Constant = (Density*Volume)/(Mass Flow Rate)
Time Constant for Mixing Process
​ Go Time Constant = (Volume/Volumetric Flow Rate of Feed to Reactor)
Transportation Lag
​ Go Transportation Lag = (Volume of Tube/Volumetric Flow Rate)

Time Constant for Heating Process Formula

Time Constant = (Density*Volume)/(Mass Flow Rate)
𝜏 = (ρ*V)/()

What is Time Constant?

Time constant means how fast the system reaches the final value. As smaller the time constant, as faster is the system response. If time constant is larger, system goes to move slow. The time constant for first order system can be defined as the time it takes for the step response to rise up to 63% or 0.63 of its final value. The reciprocal of time constant, is 1/seconds or frequency.

What is Process Dynamics and Control?

Process Dynamics is concerned with analyzing the dynamic (i.e., time dependent) behavior of a process in response to various types of inputs. In other words, it is the behavior of a process as time progresses.

How to Calculate Time Constant for Heating Process?

Time Constant for Heating Process calculator uses Time Constant = (Density*Volume)/(Mass Flow Rate) to calculate the Time Constant, The Time Constant for Heating Process formula is defined as the function of density , volume and mass flow rate. Time Constant is the “how fast” variable. It describes the speed with which the measured Process Variable (PV) responds to changes in the Controller Output (CO). More specifically it represents the time needed for the PV to reach 63.2% of its total and final change. Time Constant is denoted by 𝜏 symbol.

How to calculate Time Constant for Heating Process using this online calculator? To use this online calculator for Time Constant for Heating Process, enter Density (ρ), Volume (V) & Mass Flow Rate (ṁ) and hit the calculate button. Here is how the Time Constant for Heating Process calculation can be explained with given input values -> 619.0138 = (997.3*63)/(101.5).

FAQ

What is Time Constant for Heating Process?
The Time Constant for Heating Process formula is defined as the function of density , volume and mass flow rate. Time Constant is the “how fast” variable. It describes the speed with which the measured Process Variable (PV) responds to changes in the Controller Output (CO). More specifically it represents the time needed for the PV to reach 63.2% of its total and final change and is represented as 𝜏 = (ρ*V)/(ṁ) or Time Constant = (Density*Volume)/(Mass Flow Rate). Density of a material shows the denseness of that material in a specific given area. This is taken as mass per unit volume of a given object, Volume is the amount of space that a substance or object occupies or that is enclosed within a container & Mass flow rate is the mass of a substance that passes per unit of time. Its unit is kilogram per second in SI units.
How to calculate Time Constant for Heating Process?
The Time Constant for Heating Process formula is defined as the function of density , volume and mass flow rate. Time Constant is the “how fast” variable. It describes the speed with which the measured Process Variable (PV) responds to changes in the Controller Output (CO). More specifically it represents the time needed for the PV to reach 63.2% of its total and final change is calculated using Time Constant = (Density*Volume)/(Mass Flow Rate). To calculate Time Constant for Heating Process, you need Density (ρ), Volume (V) & Mass Flow Rate (ṁ). With our tool, you need to enter the respective value for Density, Volume & Mass Flow Rate and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Time Constant?
In this formula, Time Constant uses Density, Volume & Mass Flow Rate. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Time Constant = ((Mass*Specific Heat)/(Heat Transfer Coefficient*Area))
  • Time Constant = (Volume/Volumetric Flow Rate of Feed to Reactor)