Treatability Constant at 30 degree Celsius and 20 ft Filter Depth Solution

STEP 0: Pre-Calculation Summary
Formula Used
Treatability Constant = Treatability Constant at 30*(Depth of Actual Filter/Depth of Reference Filter)^(Empirical Constant)
K30/20 = K30/25*(D2/D1)^(a)
This formula uses 5 Variables
Variables Used
Treatability Constant - Treatability Constant at 30°C and 20 ft filter depth.
Treatability Constant at 30 - Treatability Constant at 30 and 25 ft filter depth.
Depth of Actual Filter - (Measured in Meter) - Depth of Actual Filter is the vertical dimension of the actual filter.
Depth of Reference Filter - (Measured in Meter) - Depth of Reference Filter is the vertical dimension of reference filter.
Empirical Constant - Empirical Constant influencing empirical relationships supported by confirmatory data irrespective of theoretical basis such as first principles.
STEP 1: Convert Input(s) to Base Unit
Treatability Constant at 30: 3 --> No Conversion Required
Depth of Actual Filter: 5 Meter --> 5 Meter No Conversion Required
Depth of Reference Filter: 6.1 Meter --> 6.1 Meter No Conversion Required
Empirical Constant: 0.55 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
K30/20 = K30/25*(D2/D1)^(a) --> 3*(5/6.1)^(0.55)
Evaluating ... ...
K30/20 = 2.68920151871409
STEP 3: Convert Result to Output's Unit
2.68920151871409 --> No Conversion Required
FINAL ANSWER
2.68920151871409 2.689202 <-- Treatability Constant
(Calculation completed in 00.020 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

8 Treatability Constant Calculators

Empirical Constant given Treatability Constant
Go Empirical Constant = (ln(Treatability Constant at 30/Treatability Constant)/ln(Depth of Reference Filter/Depth of Actual Filter))
Wastewater Temperature using Treatability Constant
Go Wastewater Temperature = 20+(ln(Treatability Constant/Treatability Constant at 20°C)*(1/ln(Temperature Activity Coefficient)))
Depth of Reference Filter using Treatability Constant
Go Depth of Reference Filter = Depth of Actual Filter*(Treatability Constant at 30/Treatability Constant)^(1/Empirical Constant)
Treatability Constant at 30 degree Celsius and 25 ft Filter Depth
Go Treatability Constant at 30 = Treatability Constant*(Depth of Reference Filter/Depth of Actual Filter)^(Empirical Constant)
Treatability Constant at 30 degree Celsius and 20 ft Filter Depth
Go Treatability Constant = Treatability Constant at 30*(Depth of Actual Filter/Depth of Reference Filter)^(Empirical Constant)
Temperature Activity Coefficient given Treatability Constant
Go Temperature Activity Coefficient = (Treatability Constant/Treatability Constant at 20°C)^(1/(Wastewater Temperature-20))
Treatability Constant at 30 degree Celsius and 20 ft Filter Depth
Go Treatability Constant = Treatability Constant at 20°C*(Temperature Activity Coefficient)^(Wastewater Temperature-20)
Treatability Constant at 20 degree Celsius and 20 ft Filter Depth
Go Treatability Constant at 20°C = Treatability Constant/(Temperature Activity Coefficient)^(Wastewater Temperature-20)

Treatability Constant at 30 degree Celsius and 20 ft Filter Depth Formula

Treatability Constant = Treatability Constant at 30*(Depth of Actual Filter/Depth of Reference Filter)^(Empirical Constant)
K30/20 = K30/25*(D2/D1)^(a)

What is trickling filter ?

A trickling filter is a type of wastewater treatment system. It consists of a fixed bed of rocks, coke, gravel, slag, polyurethane foam, sphagnum peat moss, ceramic, or plastic media over which sewage or other wastewater flows downward and causes a layer of microbial slime to grow, covering the bed of media.

How to Calculate Treatability Constant at 30 degree Celsius and 20 ft Filter Depth?

Treatability Constant at 30 degree Celsius and 20 ft Filter Depth calculator uses Treatability Constant = Treatability Constant at 30*(Depth of Actual Filter/Depth of Reference Filter)^(Empirical Constant) to calculate the Treatability Constant, The Treatability Constant at 30 degree Celsius and 20 ft Filter Depth when Empirical Constant is Given calculates the treatability constant when we have prior information of depth of actual and reference filter and empirical constant. Treatability Constant is denoted by K30/20 symbol.

How to calculate Treatability Constant at 30 degree Celsius and 20 ft Filter Depth using this online calculator? To use this online calculator for Treatability Constant at 30 degree Celsius and 20 ft Filter Depth, enter Treatability Constant at 30 (K30/25), Depth of Actual Filter (D2), Depth of Reference Filter (D1) & Empirical Constant (a) and hit the calculate button. Here is how the Treatability Constant at 30 degree Celsius and 20 ft Filter Depth calculation can be explained with given input values -> 3.385613 = 3*(5/6.1)^(0.55).

FAQ

What is Treatability Constant at 30 degree Celsius and 20 ft Filter Depth?
The Treatability Constant at 30 degree Celsius and 20 ft Filter Depth when Empirical Constant is Given calculates the treatability constant when we have prior information of depth of actual and reference filter and empirical constant and is represented as K30/20 = K30/25*(D2/D1)^(a) or Treatability Constant = Treatability Constant at 30*(Depth of Actual Filter/Depth of Reference Filter)^(Empirical Constant). Treatability Constant at 30 and 25 ft filter depth, Depth of Actual Filter is the vertical dimension of the actual filter, Depth of Reference Filter is the vertical dimension of reference filter & Empirical Constant influencing empirical relationships supported by confirmatory data irrespective of theoretical basis such as first principles.
How to calculate Treatability Constant at 30 degree Celsius and 20 ft Filter Depth?
The Treatability Constant at 30 degree Celsius and 20 ft Filter Depth when Empirical Constant is Given calculates the treatability constant when we have prior information of depth of actual and reference filter and empirical constant is calculated using Treatability Constant = Treatability Constant at 30*(Depth of Actual Filter/Depth of Reference Filter)^(Empirical Constant). To calculate Treatability Constant at 30 degree Celsius and 20 ft Filter Depth, you need Treatability Constant at 30 (K30/25), Depth of Actual Filter (D2), Depth of Reference Filter (D1) & Empirical Constant (a). With our tool, you need to enter the respective value for Treatability Constant at 30, Depth of Actual Filter, Depth of Reference Filter & Empirical Constant and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Treatability Constant?
In this formula, Treatability Constant uses Treatability Constant at 30, Depth of Actual Filter, Depth of Reference Filter & Empirical Constant. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Treatability Constant = Treatability Constant at 20°C*(Temperature Activity Coefficient)^(Wastewater Temperature-20)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!