Volume of Aerated Grit Chamber Solution

STEP 0: Pre-Calculation Summary
Formula Used
Volume = Assumed grit quantity*Volumetric Flow Rate
VT = G*V
This formula uses 3 Variables
Variables Used
Volume - (Measured in Cubic Meter) - Volume is the amount of space that a substance or object occupies or that is enclosed within a container.
Assumed grit quantity - Assumed grit quantity is a unit less quantity in terms of cubic meter per gallon.
Volumetric Flow Rate - (Measured in Cubic Meter per Second) - Volumetric Flow Rate is the volume of fluid which passes per unit time.
STEP 1: Convert Input(s) to Base Unit
Assumed grit quantity: 2 --> No Conversion Required
Volumetric Flow Rate: 5 Cubic Meter per Second --> 5 Cubic Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
VT = G*V --> 2*5
Evaluating ... ...
VT = 10
STEP 3: Convert Result to Output's Unit
10 Cubic Meter --> No Conversion Required
FINAL ANSWER
10 Cubic Meter <-- Volume
(Calculation completed in 00.004 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

16 Design of an Aerated Grit Chamber Calculators

Width using Length of Grit Chamber
Go Width of grit chamber = (Volume/(Depth of grit chamber*Length of grit chamber))
Depth given Length of Grit Chamber
Go Depth of grit chamber = (Volume/(Length of grit chamber*Width of grit chamber))
Length of Grit Chamber
Go Length of grit chamber = (Volume/(Width of grit chamber*Depth of grit chamber))
Volume using Length of Grit Chamber
Go Volume = (Length of grit chamber*Width of grit chamber*Depth of grit chamber)
Width of Grit Chamber
Go Width of grit chamber = (Selected width ratio*Depth of grit chamber)
Selected Width-Ratio given Width of Grit Chamber
Go Selected width ratio = Width of grit chamber/Depth of grit chamber
Chosen Depth given Width of Grit Chamber
Go Depth of grit chamber = Width of grit chamber/Selected width ratio
Chamber Length using Air supply required
Go Length of grit chamber = (Chosen air supply/Air supply required)
Chosen Air Supply given Air supply required
Go Chosen air supply = Air supply required*Length of grit chamber
Air supply required in Grit Chamber
Go Air supply required = Chosen air supply/Length of grit chamber
Assumed Grit Quantity given Volume of Aerated Grit Chamber
Go Assumed grit quantity = (Volume/Volumetric Flow Rate)
Volume Flow Rate given Volume of Aerated Grit Chamber
Go Volumetric Flow Rate = (Volume/Assumed grit quantity)
Volume of Each Grit Chamber
Go Volume = (Peak flow rate*Detention time)/(7.48*24*60)
Peak Flow Rate given Volume of Each Grit Chamber
Go Peak flow rate = (Volume*7.48*24*60)/Detention time
Detention Time given Volume of each Grit Chamber
Go Detention time = (Volume*7.48*24*60)/Peak flow rate
Volume of Aerated Grit Chamber
Go Volume = Assumed grit quantity*Volumetric Flow Rate

Volume of Aerated Grit Chamber Formula

Volume = Assumed grit quantity*Volumetric Flow Rate
VT = G*V

What is grit chamber ?

Grit chambers are long narrow tanks that are designed to slow down the flow so that solids such as sand, coffee grounds, and eggshells will settle out of the water. Grit causes excessive wear and tear on pumps and other plant equipment.

How to Calculate Volume of Aerated Grit Chamber?

Volume of Aerated Grit Chamber calculator uses Volume = Assumed grit quantity*Volumetric Flow Rate to calculate the Volume, The Volume of Aerated Grit Chamber is defined as the quantity of the grit chamber and is calculated when we know the values of grit quantity and volumetric flow rate. Volume is denoted by VT symbol.

How to calculate Volume of Aerated Grit Chamber using this online calculator? To use this online calculator for Volume of Aerated Grit Chamber, enter Assumed grit quantity (G) & Volumetric Flow Rate (V) and hit the calculate button. Here is how the Volume of Aerated Grit Chamber calculation can be explained with given input values -> 10 = 2*5.

FAQ

What is Volume of Aerated Grit Chamber?
The Volume of Aerated Grit Chamber is defined as the quantity of the grit chamber and is calculated when we know the values of grit quantity and volumetric flow rate and is represented as VT = G*V or Volume = Assumed grit quantity*Volumetric Flow Rate. Assumed grit quantity is a unit less quantity in terms of cubic meter per gallon & Volumetric Flow Rate is the volume of fluid which passes per unit time.
How to calculate Volume of Aerated Grit Chamber?
The Volume of Aerated Grit Chamber is defined as the quantity of the grit chamber and is calculated when we know the values of grit quantity and volumetric flow rate is calculated using Volume = Assumed grit quantity*Volumetric Flow Rate. To calculate Volume of Aerated Grit Chamber, you need Assumed grit quantity (G) & Volumetric Flow Rate (V). With our tool, you need to enter the respective value for Assumed grit quantity & Volumetric Flow Rate and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Volume?
In this formula, Volume uses Assumed grit quantity & Volumetric Flow Rate. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Volume = (Peak flow rate*Detention time)/(7.48*24*60)
  • Volume = (Length of grit chamber*Width of grit chamber*Depth of grit chamber)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!