Formula Used
Volume of Air Flow through Specimen = (Permeability Number*Air pressure on wall*Cross-sectional area of specimen*Time)/Specimen Height
V = (PN*ρ*A*tp)/hsp
This formula uses 6 Variables
Variables Used
Volume of Air Flow through Specimen - (Measured in Cubic Meter) - Volume of Air Flow through Specimen is the amount of air which passes through the specimen during testing.
Permeability Number - (Measured in Henry per Meter) - Permeability Number is the rate of flow of air passing through a standard specimen under a standard pressure.
Air pressure on wall - (Measured in Pascal) - Air pressure on wall is the pressure exerted by air on the walls in which it is confined.
Cross-sectional area of specimen - (Measured in Square Meter) - Cross-sectional area of specimen is the area exposed when specimen is cut transversely.
Time - (Measured in Second) - Time is the fundamental dimension of measurement.
Specimen Height - (Measured in Meter) - Specimen Height is the height of specimen defined in question.
STEP 1: Convert Input(s) to Base Unit
Permeability Number: 4.36 Henry per Meter --> 4.36 Henry per Meter No Conversion Required
Air pressure on wall: 0.0385 Kilogram-Force per Square Meter --> 0.377556024999973 Pascal (Check conversion ​here)
Cross-sectional area of specimen: 0.002027 Square Meter --> 0.002027 Square Meter No Conversion Required
Time: 3 Second --> 3 Second No Conversion Required
Specimen Height: 5 Meter --> 5 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
V = (PN*ρ*A*tp)/hsp --> (4.36*0.377556024999973*0.002027*3)/5
Evaluating ... ...
V = 0.00200204065995766
STEP 3: Convert Result to Output's Unit
0.00200204065995766 Cubic Meter --> No Conversion Required
FINAL ANSWER
0.00200204065995766 0.002002 Cubic Meter <-- Volume of Air Flow through Specimen
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rajat Vishwakarma
University Institute of Technology RGPV (UIT - RGPV), Bhopal
Rajat Vishwakarma has created this Calculator and 400+ more calculators!
Verifier Image
Verified by Nishan Poojary
Shri Madhwa Vadiraja Institute of Technology and Management (SMVITM), Udupi
Nishan Poojary has verified this Calculator and 400+ more calculators!

11 Permeability Number Calculators

Cross-Sectional Area of Specimen
​ Go Cross-sectional area of specimen = (Volume of Air Flow through Specimen*Specimen Height)/(Permeability Number*Air pressure on wall*Time)
Air Pressure during Testing
​ Go Air pressure on wall = (Volume of Air Flow through Specimen*Specimen Height)/(Permeability Number*Cross-sectional area of specimen*Time)
Time Taken during Testing
​ Go Time = (Volume of Air Flow through Specimen*Specimen Height)/(Permeability Number*Air pressure on wall*Cross-sectional area of specimen)
Volume of Air Passed through Specimen
​ Go Volume of Air Flow through Specimen = (Permeability Number*Air pressure on wall*Cross-sectional area of specimen*Time)/Specimen Height
Height of Specimen
​ Go Specimen Height = (Permeability Number*Air pressure on wall*Cross-sectional area of specimen*Time)/Volume of Air Flow through Specimen
Permeability Number
​ Go Permeability Number = (Volume of air*Height of Specimen)/(Air pressure on wall*Cross-sectional area of specimen*Time)
Grain Fineness Number
​ Go Grain Fineness Number = Sum of Product of Factor and Grams/Total Mass of Sand
Pressure during Testing or Standard Specimen
​ Go Pressure in Casting = 501.28/(Permeability Number*Time)
Permeability Number or Standard Specimen
​ Go Permeability Number = 501.28/(Pressure in Casting*Time)
Time Taken in Standard Specimen Testing
​ Go Time = 501.28/(Permeability Number*Pressure in Casting)
Ranginess Factor
​ Go Ranginess Factor = Modulus of Cube/Modulus of Casting

Volume of Air Passed through Specimen Formula

Volume of Air Flow through Specimen = (Permeability Number*Air pressure on wall*Cross-sectional area of specimen*Time)/Specimen Height
V = (PN*ρ*A*tp)/hsp

What is permeability number?

The Permeability Number the rate of flow of air passing through a standard specimen under a standard pressure.
The standard permeability test is to measure time taken by a 2000 cub cm of air at a pressure typically of 980 Pa (10 g/cm2), to pass through a standard sand specimen confined in a specimen tube. The standard specimen size is 50.8 mm in diameter and a length of 50.8 mm.

How to Calculate Volume of Air Passed through Specimen?

Volume of Air Passed through Specimen calculator uses Volume of Air Flow through Specimen = (Permeability Number*Air pressure on wall*Cross-sectional area of specimen*Time)/Specimen Height to calculate the Volume of Air Flow through Specimen, The Volume of air passed through specimen is the amount that passes through the specimen during testing. Volume of Air Flow through Specimen is denoted by V symbol.

How to calculate Volume of Air Passed through Specimen using this online calculator? To use this online calculator for Volume of Air Passed through Specimen, enter Permeability Number (PN), Air pressure on wall (ρ), Cross-sectional area of specimen (A), Time (tp) & Specimen Height (hsp) and hit the calculate button. Here is how the Volume of Air Passed through Specimen calculation can be explained with given input values -> 0.001997 = (4.36*0.377556024999973*0.002027*3)/5.

FAQ

What is Volume of Air Passed through Specimen?
The Volume of air passed through specimen is the amount that passes through the specimen during testing and is represented as V = (PN*ρ*A*tp)/hsp or Volume of Air Flow through Specimen = (Permeability Number*Air pressure on wall*Cross-sectional area of specimen*Time)/Specimen Height. Permeability Number is the rate of flow of air passing through a standard specimen under a standard pressure, Air pressure on wall is the pressure exerted by air on the walls in which it is confined, Cross-sectional area of specimen is the area exposed when specimen is cut transversely, Time is the fundamental dimension of measurement & Specimen Height is the height of specimen defined in question.
How to calculate Volume of Air Passed through Specimen?
The Volume of air passed through specimen is the amount that passes through the specimen during testing is calculated using Volume of Air Flow through Specimen = (Permeability Number*Air pressure on wall*Cross-sectional area of specimen*Time)/Specimen Height. To calculate Volume of Air Passed through Specimen, you need Permeability Number (PN), Air pressure on wall (ρ), Cross-sectional area of specimen (A), Time (tp) & Specimen Height (hsp). With our tool, you need to enter the respective value for Permeability Number, Air pressure on wall, Cross-sectional area of specimen, Time & Specimen Height and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!