Well Loss given Drawdown Solution

STEP 0: Pre-Calculation Summary
Formula Used
Head Loss in well = Total Drawdown in Well-Aquifer loss
CQn = st-BQ
This formula uses 3 Variables
Variables Used
Head Loss in well - (Measured in Meter) - The Head Loss in well is essentially the difference between the head of the aquifer immediately outside and in the well a head inside because of all these losses.
Total Drawdown in Well - (Measured in Meter) - The Total Drawdown in Well is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test.
Aquifer loss - (Measured in Meter) - Aquifer loss is product of discharge and aquifer loss coefficient.
STEP 1: Convert Input(s) to Base Unit
Total Drawdown in Well: 0.83 Meter --> 0.83 Meter No Conversion Required
Aquifer loss: 27.13 Meter --> 27.13 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
CQn = st-BQ --> 0.83-27.13
Evaluating ... ...
CQn = -26.3
STEP 3: Convert Result to Output's Unit
-26.3 Meter --> No Conversion Required
FINAL ANSWER
-26.3 Meter <-- Head Loss in well
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

2 Well Loss Calculators

Well Loss given Specific Capacity
​ Go Head Loss in well = (Discharge/Specific Capacity)-Aquifer loss
Well Loss given Drawdown
​ Go Head Loss in well = Total Drawdown in Well-Aquifer loss

Well Loss given Drawdown Formula

Head Loss in well = Total Drawdown in Well-Aquifer loss
CQn = st-BQ

What is Well Loss?

When water is pumped out of a well, the total drawdown caused includes not only that of the logarithmic drawdown curve at the well face, but also drawdown caused by flow through well screen and axial movement within the well. The latter drawdown is called well loss.

How to Calculate Well Loss given Drawdown?

Well Loss given Drawdown calculator uses Head Loss in well = Total Drawdown in Well-Aquifer loss to calculate the Head Loss in well, The Well Loss given Drawdown is defined as the value of well loss when we have prior information of other parameters used. Head Loss in well is denoted by CQn symbol.

How to calculate Well Loss given Drawdown using this online calculator? To use this online calculator for Well Loss given Drawdown, enter Total Drawdown in Well (st) & Aquifer loss (BQ) and hit the calculate button. Here is how the Well Loss given Drawdown calculation can be explained with given input values -> -27.029 = 0.83-27.13.

FAQ

What is Well Loss given Drawdown?
The Well Loss given Drawdown is defined as the value of well loss when we have prior information of other parameters used and is represented as CQn = st-BQ or Head Loss in well = Total Drawdown in Well-Aquifer loss. The Total Drawdown in Well is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test & Aquifer loss is product of discharge and aquifer loss coefficient.
How to calculate Well Loss given Drawdown?
The Well Loss given Drawdown is defined as the value of well loss when we have prior information of other parameters used is calculated using Head Loss in well = Total Drawdown in Well-Aquifer loss. To calculate Well Loss given Drawdown, you need Total Drawdown in Well (st) & Aquifer loss (BQ). With our tool, you need to enter the respective value for Total Drawdown in Well & Aquifer loss and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Head Loss in well?
In this formula, Head Loss in well uses Total Drawdown in Well & Aquifer loss. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Head Loss in well = (Discharge/Specific Capacity)-Aquifer loss