Width of Chromatographic Peak using Column Efficiency Solution

STEP 0: Pre-Calculation Summary
Formula Used
Width of Chromatographic Peak = Retention Volume/(sqrt(Column Efficiency/16))
Wb = VR/(sqrt(N/16))
This formula uses 1 Functions, 3 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Width of Chromatographic Peak - (Measured in Meter) - Width of Chromatographic Peak is the distance between points where lines tangent to the peak's left and right inflection points intersect the baseline.
Retention Volume - (Measured in Cubic Meter) - The Retention Volume is defined as the volume of the mobile phase required to elute the solute from the column.
Column Efficiency - Column Efficiency, also known as plate count, is a measure of the dispersion of a peak.
STEP 1: Convert Input(s) to Base Unit
Retention Volume: 11.2 Liter --> 0.0112 Cubic Meter (Check conversion here)
Column Efficiency: 5.5 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Wb = VR/(sqrt(N/16)) --> 0.0112/(sqrt(5.5/16))
Evaluating ... ...
Wb = 0.0191027841854627
STEP 3: Convert Result to Output's Unit
0.0191027841854627 Meter -->19.1027841854627 Millimeter (Check conversion here)
FINAL ANSWER
19.1027841854627 19.10278 Millimeter <-- Width of Chromatographic Peak
(Calculation completed in 00.004 seconds)

Credits

Created by Soupayan banerjee
National University of Judicial Science (NUJS), Kolkata
Soupayan banerjee has created this Calculator and 200+ more calculators!
Verified by Pratibha
Amity Institute Of Applied Sciences (AIAS, Amity University), Noida, India
Pratibha has verified this Calculator and 50+ more calculators!

17 Osmolality Calculators

Peak Resolution in Chromatography
Go Peak Resolution = (Retention Volume of Molecule 2-Retention Volume of Molecule 1)/((Width of Chromatographic Peak of Molecule 1+Widths of Chromatographic Peak of Molecule 2)/2)
Blood Urea Nitrogen using Calculated Serum Osmolality
Go Blood Urea Nitrogen = 2.8*((Calculated Serum Osmolality)-(2*Serum Sodium)-(Serum Glucose/18))
Serum Glucose using Calculated Serum Osmolality
Go Serum Glucose = 18*((Calculated Serum Osmolality)-(2*Serum Sodium)-(Blood Urea Nitrogen/2.8))
Serum Sodium using Calculated Serum Osmolality
Go Serum Sodium = ((Calculated Serum Osmolality)-(Serum Glucose/18)-(Blood Urea Nitrogen/2.8))/2
Calculated Serum Osmolality
Go Calculated Serum Osmolality = (2*Serum Sodium)+(Serum Glucose/18)+(Blood Urea Nitrogen/2.8)
Width of Chromatographic Peak using Column Efficiency
Go Width of Chromatographic Peak = Retention Volume/(sqrt(Column Efficiency/16))
Retention Volume using Column Efficiency
Go Retention Volume = Width of Chromatographic Peak*(sqrt(Column Efficiency/16))
Column Efficiency in Chromatography
Go Column Efficiency = 16*((Retention Volume/ Width of Chromatographic Peak)^2)
Increase of Splicing Potential by Wild-type Sequence
Go Splicing Potential = log10(Weight Factor for Increase of Splicing Potential)
Calculated Serum Osmolality using Osmolar Gap
Go Calculated Serum Osmolality = Measured Osmolality-Osmolar Gap
Measured Osmolality using Osmolar Gap
Go Measured Osmolality = Osmolar Gap+Calculated Serum Osmolality
Osmolar Gap
Go Osmolar Gap = Measured Osmolality-Calculated Serum Osmolality
Total Volume of Mobile Phase within Column given Retention Factor
Go Void Volume = Retention Volume/(Retention Factor+1)
Retention Volume using Retention Factor
Go Retention Volume = Void Volume*(Retention Factor+1)
Decrease of Splicing Potential by Mutant Sequence
Go Splicing Potential = -log10(Weight Factor)
Plasma Osmolality
Go Plasma Osmolality = (2*Sodium Concentration in Plasma)
Plasma Concentration using Plasma Osmolality
Go Sodium Concentration in Plasma = Plasma Osmolality/2

Width of Chromatographic Peak using Column Efficiency Formula

Width of Chromatographic Peak = Retention Volume/(sqrt(Column Efficiency/16))
Wb = VR/(sqrt(N/16))

What is Column Chromatography?

Column chromatography in chemistry is a chromatography method used to isolate a single chemical compound from a mixture. Chromatography is able to separate substances based on differential adsorption of compounds to the adsorbent; compounds move through the column at different rates, allowing them to be separated into fractions. The technique is widely applicable, as many different adsorbents (normal phase, reversed phase, or otherwise) can be used with a wide range of solvents.

How to Calculate Width of Chromatographic Peak using Column Efficiency?

Width of Chromatographic Peak using Column Efficiency calculator uses Width of Chromatographic Peak = Retention Volume/(sqrt(Column Efficiency/16)) to calculate the Width of Chromatographic Peak, The Width of Chromatographic Peak using Column Efficiency formula is defined as the peak's full width at half maximum. Lower peak widths indicates better chromatographic resolution. Width of Chromatographic Peak is denoted by Wb symbol.

How to calculate Width of Chromatographic Peak using Column Efficiency using this online calculator? To use this online calculator for Width of Chromatographic Peak using Column Efficiency, enter Retention Volume (VR) & Column Efficiency (N) and hit the calculate button. Here is how the Width of Chromatographic Peak using Column Efficiency calculation can be explained with given input values -> 19102.78 = 0.0112/(sqrt(5.5/16)).

FAQ

What is Width of Chromatographic Peak using Column Efficiency?
The Width of Chromatographic Peak using Column Efficiency formula is defined as the peak's full width at half maximum. Lower peak widths indicates better chromatographic resolution and is represented as Wb = VR/(sqrt(N/16)) or Width of Chromatographic Peak = Retention Volume/(sqrt(Column Efficiency/16)). The Retention Volume is defined as the volume of the mobile phase required to elute the solute from the column & Column Efficiency, also known as plate count, is a measure of the dispersion of a peak.
How to calculate Width of Chromatographic Peak using Column Efficiency?
The Width of Chromatographic Peak using Column Efficiency formula is defined as the peak's full width at half maximum. Lower peak widths indicates better chromatographic resolution is calculated using Width of Chromatographic Peak = Retention Volume/(sqrt(Column Efficiency/16)). To calculate Width of Chromatographic Peak using Column Efficiency, you need Retention Volume (VR) & Column Efficiency (N). With our tool, you need to enter the respective value for Retention Volume & Column Efficiency and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!