Wind Load Effect given Ultimate Strength for Applied Wind Loads Solution

STEP 0: Pre-Calculation Summary
Formula Used
Wind Load = (Ultimate Strength-(0.9*Dead Load))/(1.3)
W = (U-(0.9*DL))/(1.3)
This formula uses 3 Variables
Variables Used
Wind Load - (Measured in Pascal) - Wind Load is the load, placed on the exterior of a structure by wind.
Ultimate Strength - (Measured in Pascal) - ultimate strengths is the capacities to resist design loads and their related internal moments and forces.
Dead Load - (Measured in Pascal) - Dead Load consisting of basic load plus volume change due to (shrinkage,temperature).
STEP 1: Convert Input(s) to Base Unit
Ultimate Strength: 20 Kilonewton per Square Meter --> 20000 Pascal (Check conversion ​here)
Dead Load: 10.01 Kilonewton per Square Meter --> 10010 Pascal (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
W = (U-(0.9*DL))/(1.3) --> (20000-(0.9*10010))/(1.3)
Evaluating ... ...
W = 8454.61538461538
STEP 3: Convert Result to Output's Unit
8454.61538461538 Pascal -->8.45461538461539 Kilonewton per Square Meter (Check conversion ​here)
FINAL ANSWER
8.45461538461539 8.454615 Kilonewton per Square Meter <-- Wind Load
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verifier Image
Verified by Alithea Fernandes
Don Bosco College of Engineering (DBCE), Goa
Alithea Fernandes has verified this Calculator and 100+ more calculators!

6 Partial Safety Factors for Loads Calculators

Basic Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads
​ Go Dead Load = (Ultimate Strength-(1.7*Live Load))/(1.4)
Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads
​ Go Live Load = (Ultimate Strength-(1.4*Dead Load))/(1.7)
Basic Load Effect given Ultimate Strength for Applied Wind Loads
​ Go Dead Load = (Ultimate Strength-(1.3*Wind Load))/(0.9)
Wind Load Effect given Ultimate Strength for Applied Wind Loads
​ Go Wind Load = (Ultimate Strength-(0.9*Dead Load))/(1.3)
Ultimate Strength when Wind and Earthquake Loads are not Applied
​ Go Ultimate Strength = (1.4*Dead Load)+(1.7*Live Load)
Ultimate Strength when Wind Loads are Applied
​ Go Ultimate Strength = (0.9*Dead Load)+(1.3*Wind Load)

Wind Load Effect given Ultimate Strength for Applied Wind Loads Formula

Wind Load = (Ultimate Strength-(0.9*Dead Load))/(1.3)
W = (U-(0.9*DL))/(1.3)

What is Wind Load?

Wind load is primarily horizontal load caused by the movement of air relative to earth. Wind load is required to be considered in structural design especially when the heath of the building exceeds two times the dimensions transverse to the exposed wind surface.

How to Calculate Wind Load Effect given Ultimate Strength for Applied Wind Loads?

Wind Load Effect given Ultimate Strength for Applied Wind Loads calculator uses Wind Load = (Ultimate Strength-(0.9*Dead Load))/(1.3) to calculate the Wind Load, The Wind Load Effect given Ultimate Strength for Applied Wind Loads formula is defined as the load, placed on the exterior of a structure by wind. Wind Load is denoted by W symbol.

How to calculate Wind Load Effect given Ultimate Strength for Applied Wind Loads using this online calculator? To use this online calculator for Wind Load Effect given Ultimate Strength for Applied Wind Loads, enter Ultimate Strength (U) & Dead Load (DL) and hit the calculate button. Here is how the Wind Load Effect given Ultimate Strength for Applied Wind Loads calculation can be explained with given input values -> 0.008462 = (20000-(0.9*10010))/(1.3).

FAQ

What is Wind Load Effect given Ultimate Strength for Applied Wind Loads?
The Wind Load Effect given Ultimate Strength for Applied Wind Loads formula is defined as the load, placed on the exterior of a structure by wind and is represented as W = (U-(0.9*DL))/(1.3) or Wind Load = (Ultimate Strength-(0.9*Dead Load))/(1.3). ultimate strengths is the capacities to resist design loads and their related internal moments and forces & Dead Load consisting of basic load plus volume change due to (shrinkage,temperature).
How to calculate Wind Load Effect given Ultimate Strength for Applied Wind Loads?
The Wind Load Effect given Ultimate Strength for Applied Wind Loads formula is defined as the load, placed on the exterior of a structure by wind is calculated using Wind Load = (Ultimate Strength-(0.9*Dead Load))/(1.3). To calculate Wind Load Effect given Ultimate Strength for Applied Wind Loads, you need Ultimate Strength (U) & Dead Load (DL). With our tool, you need to enter the respective value for Ultimate Strength & Dead Load and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.