50 Matching calculators found!
Ambient Temperature (
522 Calculations)
The Ambient Temperature formula is defined as the ambient Temperature where there ECM is being performed.
Rocket Exit Temperature (
233 Calculations)
The Rocket Exit Temperature formula defines the exit Temperature at an exhaust, given that we know the total Temperature and Mach number.
Excess Temperature in Boiling (
94 Calculations)
The Excess Temperature in Boiling formula is defined as the difference between the surface Temperature and saturated Temperature.
Biot Number using Fourier Number (
1158 Calculations)
The Biot Number using Fourier Number formula is defined as the function of Temperature at any time t , Temperature of bulk fluid, initial Temperature and fourier number.
Temperature after given time elapsed (
387 Calculations)
The Temperature after given time elapsed formula calculates the Temperature of the lumped body for the given time by using Temperature-Time relation.
Temperature given Gibbs free entropy (
14 Calculations)
The Temperature given Gibbs free entropy formula is defined as the relation of Temperature with internal energy and change in entropy at particular Temperature, pressure, and volume.
Time taken to reach given Temperature (
3197 Calculations)
The Time taken to reach given Temperature formula calculates the time required for a lumped body to reach a certain Temperature by using the Temperature-Time relation for the lumped body.
Surface Entropy given Critical Temperature (
26 Calculations)
The Surface Entropy given Critical Temperature formula is defined as the difference between the surface tension (dependent on Temperature) and reciprocal of critical Temperature.
Lapse rate (
45536 Calculations)
Lapse Rate is a measure of the rate of decrease in Temperature with an increase in altitude, typically expressed as a ratio of the change in Temperature to the altitude difference.
Room Temperature (
2251 Calculations)
The Room Temperature formula is defined as is the range of air Temperatures that most people prefer for indoor settings, which feel comfortable when wearing typical indoor clothing.
Temperature Strain (
29 Calculations)
The Temperature Strain formula is defined as change in length divided by original length due to Temperature.
Rise in Temperature (
61 Calculations)
The Rise in Temperature formula is defined as the increase in Temperature observed either as a result of the transducer's operation or because of external factors affecting the transducer.
Membrane Temperature (
27 Calculations)
The Membrane Temperature formula is defined as the Temperature of the membrane at a unit volumetric flux and applied pressure driving force.
Critical Temperature (
809 Calculations)
The Critical Temperature at a point in a fluid flow is defined as the Temperature that would exist if the flow became sonic at that point.
Dew Point Depression (
8700 Calculations)
Dew Point Depression (T-Td) is the difference between the Temperature and dew point Temperature at a certain height in the atmosphere.
Wet Bulb Temperature (
636 Calculations)
The Wet Bulb Temperature formula is defined as the lowest Temperature of air that is possible if water if added at constant pressure in air-water mixture.
Temperature Lapse Rate (
148 Calculations)
The Temperature Lapse Rate (dT/dZ) is the rate at which an atmospheric variable, normally Temperature in Earth's atmosphere, falls with altitude.
Final Temperature of Pipe (
32 Calculations)
The Final Temperature of Pipe formula is defined as the value of Temperature that a pipe or pipeline reaches after being exposed to various environmental and operational factors over time.
Melting Temperature of Metal (
206 Calculations)
The Melting Temperature of Metal formula is defined as the Temperature at which the material changes the state to liquid from solid.
Modified Heat of Vaporization (
26 Calculations)
The Modified Heat of Vaporization formula is defined as the function of latent heat of vapourization, specific heat of water vapor, plate surface Temperature and saturated Temperature.
Entry Temperature of hot fluid (
206 Calculations)
The Entry Temperature of hot fluid formula is defined as the Temperature of hot fluid entering the heat exchanger.
Ambient Temperature during LBM (
57 Calculations)
The Ambient Temperature during LBM formula is defined as the Temperature of the surrounding where LBM is being performed.
Entry Temperature of cold fluid (
263 Calculations)
The Entry Temperature of cold fluid formula is defined as the Temperature of the cold fluid entering the heat exchanger.
Adiabatic Saturation Temperature (
83 Calculations)
The Adiabatic Saturation Temperature formula is defined as the humidity saturation Temperature of the inlet air undergoing an adiabatic process.
Isothermal Work using Temperature (
1019 Calculations)
Isothermal Work using Temperature is the energy transferred to or from an object via the application of force along with a displacement for a system whose Temperature is constant.
Surface Tension given Temperature (
1389 Calculations)
The Surface Tension given Temperature formula is a relationship that allows one to calculate the magnitude of surface tension at different Temperatures.
Voltage Equivalent of Temperature (
29696 Calculations)
Voltage Equivalent of Temperature is the equivalent value which can be found out by dividing the Temperature value by 11600.
Radiation Heat Transfer Coefficient (
197 Calculations)
The Radiation Heat Transfer Coefficient formula is defined as the function of stefan boltzmann constant, emissivity, plate surface Temperature and Saturated Temperature.
Jet velocity given Temperature drop (
320 Calculations)
The Jet velocity given Temperature drop formula is defined as the square root of 2 times the product of specific heat at constant pressure and Temperature drop.