Aquifer Loss Coefficient given Specific Capacity Solution

STEP 0: Pre-Calculation Summary
Formula Used
Aquifer Loss Coefficient = ((Discharge/Specific Capacity)-Head Loss in well)/Discharge
B = ((Q/Sc)-CQn)/Q
This formula uses 4 Variables
Variables Used
Aquifer Loss Coefficient - Aquifer Loss Coefficient is constant for a given flow rate.
Discharge - (Measured in Cubic Meter per Second) - Discharge is the rate of flow of a liquid.
Specific Capacity - (Measured in Square Meter per Second) - Specific Capacity is the quantity that which a water well can produce per unit of drawdown.
Head Loss in well - (Measured in Meter) - The Head Loss in well is essentially the difference between the head of the aquifer immediately outside and in the well a head inside because of all these losses.
STEP 1: Convert Input(s) to Base Unit
Discharge: 1.01 Cubic Meter per Second --> 1.01 Cubic Meter per Second No Conversion Required
Specific Capacity: 0.037 Square Meter per Second --> 0.037 Square Meter per Second No Conversion Required
Head Loss in well: 0.091 Meter --> 0.091 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
B = ((Q/Sc)-CQn)/Q --> ((1.01/0.037)-0.091)/1.01
Evaluating ... ...
B = 26.936928017126
STEP 3: Convert Result to Output's Unit
26.936928017126 --> No Conversion Required
FINAL ANSWER
26.936928017126 26.93693 <-- Aquifer Loss Coefficient
(Calculation completed in 00.020 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

7 Specific Capacity of Well Calculators

Aquifer Loss Coefficient given Specific Capacity
Go Aquifer Loss Coefficient = ((Discharge/Specific Capacity)-Head Loss in well)/Discharge
Specific Capacity given Aquifer Loss
Go Specific Capacity = (Discharge/(Head Loss in well+Aquifer loss))
Well Discharge given Specific Capacity
Go Discharge = Specific Capacity*(Head Loss in well+Aquifer loss)
Aquifer Loss given Specific Capacity
Go Aquifer loss = (Discharge/Specific Capacity)-Head Loss in well
Drawdown given Specific Capacity of Well
Go Total Drawdown in Well = Discharge/Specific Capacity
Discharge given Specific Capacity
Go Discharge = Specific Capacity*Total Drawdown in Well
Specific Capacity given Drawdown
Go Specific Capacity = Discharge/Total Drawdown in Well

Aquifer Loss Coefficient given Specific Capacity Formula

Aquifer Loss Coefficient = ((Discharge/Specific Capacity)-Head Loss in well)/Discharge
B = ((Q/Sc)-CQn)/Q

What is Aquifer?

An aquifer is a body of rock and/or sediment that holds groundwater. Groundwater is the word used to describe precipitation that has infiltrated the soil beyond the surface and collected in empty spaces underground.

How to Calculate Aquifer Loss Coefficient given Specific Capacity?

Aquifer Loss Coefficient given Specific Capacity calculator uses Aquifer Loss Coefficient = ((Discharge/Specific Capacity)-Head Loss in well)/Discharge to calculate the Aquifer Loss Coefficient, The Aquifer Loss Coefficient given Specific Capacity is defined as the value of aquifer loss coefficient when we have prior information of other parameters used. Aquifer Loss Coefficient is denoted by B symbol.

How to calculate Aquifer Loss Coefficient given Specific Capacity using this online calculator? To use this online calculator for Aquifer Loss Coefficient given Specific Capacity, enter Discharge (Q), Specific Capacity (Sc) & Head Loss in well (CQn) and hit the calculate button. Here is how the Aquifer Loss Coefficient given Specific Capacity calculation can be explained with given input values -> 7.052758 = ((1.01/0.037)-0.091)/1.01.

FAQ

What is Aquifer Loss Coefficient given Specific Capacity?
The Aquifer Loss Coefficient given Specific Capacity is defined as the value of aquifer loss coefficient when we have prior information of other parameters used and is represented as B = ((Q/Sc)-CQn)/Q or Aquifer Loss Coefficient = ((Discharge/Specific Capacity)-Head Loss in well)/Discharge. Discharge is the rate of flow of a liquid, Specific Capacity is the quantity that which a water well can produce per unit of drawdown & The Head Loss in well is essentially the difference between the head of the aquifer immediately outside and in the well a head inside because of all these losses.
How to calculate Aquifer Loss Coefficient given Specific Capacity?
The Aquifer Loss Coefficient given Specific Capacity is defined as the value of aquifer loss coefficient when we have prior information of other parameters used is calculated using Aquifer Loss Coefficient = ((Discharge/Specific Capacity)-Head Loss in well)/Discharge. To calculate Aquifer Loss Coefficient given Specific Capacity, you need Discharge (Q), Specific Capacity (Sc) & Head Loss in well (CQn). With our tool, you need to enter the respective value for Discharge, Specific Capacity & Head Loss in well and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!