Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 500+ more calculators!
Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 500+ more calculators!

11 Other formulas that you can solve using the same Inputs

Drainage Area when Peak Discharge given in Field Application
Drainage Area=Peak Discharge/(1/3.6)*Coefficient of Runoff*Mean Intensity of Precipitation Go
Mixed Liquor Suspended Solids in Aeration Tank when Maximum Solids is Given
mlss=(Maximum solids/((Peak Discharge+Return activated sludge)*8.34)) Go
Return Activated Sludge Flow Rate when Maximum Solids Entering the Clarifier is Given
Return activated sludge=(Maximum solids/(mlss*8.34))-Peak Discharge Go
Maximum Solids Entering the Clarifier
Maximum solids=(Peak Discharge+Return activated sludge)*mlss*8.34 Go
Catchment Area when maximum Flood Discharge is known in Ryve’s formula
Catchment Area=(Peak Discharge/Ryves Coefficient)^1/0.66 Go
Catchment Area when maximum Flood Discharge is known in Dickens Formula
Catchment Area=(Peak Discharge/Dickens Constant)^1/0.75 Go
Design Surface Loading Rate when Surface Area of Circular Settling Tank is Given
Surface loading rate=(Peak Discharge/Surface Area) Go
Peaking Factor when Peak Discharge in Circular Settling Tanks is Given
Peaking factor=(Peak Discharge/Average daily load) Go
Surface Area of Circular Settling Tank
Surface Area=(Peak Discharge/Surface loading rate) Go
Peak Discharge in Circular Settling Tanks
Peak Discharge=Average daily load*Peaking factor Go
Catchment Area when Peak Discharge is given in Jarvis formula
Catchment Area=(Peak Discharge/Coefficient)^2 Go

Average Daily Load when Peak Discharge in Circular Settling Tanks is Given Formula

Average daily load=(Peak Discharge/Peaking factor)
q=(Q<sub>p</sub>/f)
More formulas
Peak Discharge in Circular Settling Tanks Go
Peaking Factor when Peak Discharge in Circular Settling Tanks is Given Go
Surface Area of Circular Settling Tank Go
Peak Discharge when Surface Area of Circular Settling Tank is Given Go
Design Surface Loading Rate when Surface Area of Circular Settling Tank is Given Go
Return Activated Sludge Flow Rate Go
Influent Flow Rate when Return Activated Sludge Flow Rate is Given Go
Maximum Solids Entering the Clarifier Go
Peak Discharge when Maximum Solids Entering the Clarifier is Given Go
Return Activated Sludge Flow Rate when Maximum Solids Entering the Clarifier is Given Go
Mixed Liquor Suspended Solids in Aeration Tank when Maximum Solids is Given Go
Assumed Solid Loading Rate of Circular Settling Tanks Go
Maximum Solids when Solid Loading Rate is Given Go
Surface Area when Solid Loading Rate is Given Go
Actual Solid Loading Rate of Circular Settling Tanks Go
Solids Processed when Actual Solid Loading Rate is Given Go
Total Settling Tank Surface Area when Actual Solid Loading Rate is Given Go

What is average daily demand?

Average Daily Demand (ADD) - The total volume of water delivered to the system over a year divided by 365 days. The average use in a single day expressed in gallons per day.

How to Calculate Average Daily Load when Peak Discharge in Circular Settling Tanks is Given?

Average Daily Load when Peak Discharge in Circular Settling Tanks is Given calculator uses Average daily load=(Peak Discharge/Peaking factor) to calculate the Average daily load, The Average Daily Load when Peak Discharge in Circular Settling Tanks is Given is defined as a customer's average daily consumption of water in mld. Average daily load and is denoted by q symbol.

How to calculate Average Daily Load when Peak Discharge in Circular Settling Tanks is Given using this online calculator? To use this online calculator for Average Daily Load when Peak Discharge in Circular Settling Tanks is Given, enter Peak Discharge (Qp) and Peaking factor (f) and hit the calculate button. Here is how the Average Daily Load when Peak Discharge in Circular Settling Tanks is Given calculation can be explained with given input values -> 5 = (10/2).

FAQ

What is Average Daily Load when Peak Discharge in Circular Settling Tanks is Given?
The Average Daily Load when Peak Discharge in Circular Settling Tanks is Given is defined as a customer's average daily consumption of water in mld and is represented as q=(Qp/f) or Average daily load=(Peak Discharge/Peaking factor). Peak Discharge is the maximum volume flow rate passing a particular location during a storm event and Peaking factor is the ratio of the maximum flow to the average daily flow in a water system. .
How to calculate Average Daily Load when Peak Discharge in Circular Settling Tanks is Given?
The Average Daily Load when Peak Discharge in Circular Settling Tanks is Given is defined as a customer's average daily consumption of water in mld is calculated using Average daily load=(Peak Discharge/Peaking factor). To calculate Average Daily Load when Peak Discharge in Circular Settling Tanks is Given, you need Peak Discharge (Qp) and Peaking factor (f). With our tool, you need to enter the respective value for Peak Discharge and Peaking factor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Share Image
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!