BOD5 of Settled Effluent from Trickling Filter Solution

STEP 0: Pre-Calculation Summary
Formula Used
Effluent BOD = Influent BOD*exp(-1*Treatability Constant*Depth of actual filter*(Volumetric flow per unit area)^(-1*Empirical Constant))
Qo = Qi*exp(-1*K30/25*D2*(Qv)^(-1*A0))
This formula uses 1 Functions, 6 Variables
Functions Used
exp - n an exponential function, the value of the function changes by a constant factor for every unit change in the independent variable., exp(Number)
Variables Used
Effluent BOD - (Measured in Kilogram per Cubic Meter) - Effluent BOD is the amount of BOD present in the outing sewage.
Influent BOD - (Measured in Kilogram per Cubic Meter) - Influent BOD is the total amount of BOD which is present in the incoming sewage.
Treatability Constant - Treatability Constant at 30°C and 25 ft filter depth.
Depth of actual filter - (Measured in Meter) - Depth of actual filter is the virtical dimension of the actuall filter.
Volumetric flow per unit area - (Measured in Meter per Second) - Volumetric flow per unit area of filter unit.
Empirical Constant - The Empirical constant is a self determined constant whose value is accessible from table of such constants. This constant is used to calculate the intrinsic carrier concentration.
STEP 1: Convert Input(s) to Base Unit
Influent BOD: 11.2 Milligram per Liter --> 0.0112 Kilogram per Cubic Meter (Check conversion here)
Treatability Constant: 3 --> No Conversion Required
Depth of actual filter: 7.6 Meter --> 7.6 Meter No Conversion Required
Volumetric flow per unit area: 5 Meter per Second --> 5 Meter per Second No Conversion Required
Empirical Constant: 100 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Qo = Qi*exp(-1*K30/25*D2*(Qv)^(-1*A0)) --> 0.0112*exp(-1*3*7.6*(5)^(-1*100))
Evaluating ... ...
Qo = 0.0112
STEP 3: Convert Result to Output's Unit
0.0112 Kilogram per Cubic Meter -->11.2 Milligram per Liter (Check conversion here)
FINAL ANSWER
11.2 Milligram per Liter <-- Effluent BOD
(Calculation completed in 00.020 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

3 Biodegradable Oxygen Demand Calculators

BOD5 of Influent Wastewater to Trickling Filter
Go Influent BOD = ((Effluent BOD)/(exp(-1*Treatability Constant*Depth of actual filter*(Volumetric flow per unit area)^(-1*Empirical Constant))))
BOD5 of Settled Effluent from Trickling Filter
Go Effluent BOD = Influent BOD*exp(-1*Treatability Constant*Depth of actual filter*(Volumetric flow per unit area)^(-1*Empirical Constant))
BOD5 Load given Organic Loading
Go BOD loading to filter = Organic loading*Area of filter*Filter length

BOD5 of Settled Effluent from Trickling Filter Formula

Effluent BOD = Influent BOD*exp(-1*Treatability Constant*Depth of actual filter*(Volumetric flow per unit area)^(-1*Empirical Constant))
Qo = Qi*exp(-1*K30/25*D2*(Qv)^(-1*A0))

What is effluent ?

Effluent is an outflowing of water or gas to a natural body of water, from a structure such as a wastewater treatment plant, sewer pipe, or industrial outfall. Effluent, in engineering, is the stream exiting a chemical reactor.

How to Calculate BOD5 of Settled Effluent from Trickling Filter?

BOD5 of Settled Effluent from Trickling Filter calculator uses Effluent BOD = Influent BOD*exp(-1*Treatability Constant*Depth of actual filter*(Volumetric flow per unit area)^(-1*Empirical Constant)) to calculate the Effluent BOD, BOD5 of Settled Effluent from Trickling Filter the amount of dissolved oxygen needed by aerobic biological organisms to break down organic material present in a given water. Effluent BOD is denoted by Qo symbol.

How to calculate BOD5 of Settled Effluent from Trickling Filter using this online calculator? To use this online calculator for BOD5 of Settled Effluent from Trickling Filter, enter Influent BOD (Qi), Treatability Constant (K30/25), Depth of actual filter (D2), Volumetric flow per unit area (Qv) & Empirical Constant (A0) and hit the calculate button. Here is how the BOD5 of Settled Effluent from Trickling Filter calculation can be explained with given input values -> 11200 = 0.0112*exp(-1*3*7.6*(5)^(-1*100)).

FAQ

What is BOD5 of Settled Effluent from Trickling Filter?
BOD5 of Settled Effluent from Trickling Filter the amount of dissolved oxygen needed by aerobic biological organisms to break down organic material present in a given water and is represented as Qo = Qi*exp(-1*K30/25*D2*(Qv)^(-1*A0)) or Effluent BOD = Influent BOD*exp(-1*Treatability Constant*Depth of actual filter*(Volumetric flow per unit area)^(-1*Empirical Constant)). Influent BOD is the total amount of BOD which is present in the incoming sewage, Treatability Constant at 30°C and 25 ft filter depth, Depth of actual filter is the virtical dimension of the actuall filter, Volumetric flow per unit area of filter unit & The Empirical constant is a self determined constant whose value is accessible from table of such constants. This constant is used to calculate the intrinsic carrier concentration.
How to calculate BOD5 of Settled Effluent from Trickling Filter?
BOD5 of Settled Effluent from Trickling Filter the amount of dissolved oxygen needed by aerobic biological organisms to break down organic material present in a given water is calculated using Effluent BOD = Influent BOD*exp(-1*Treatability Constant*Depth of actual filter*(Volumetric flow per unit area)^(-1*Empirical Constant)). To calculate BOD5 of Settled Effluent from Trickling Filter, you need Influent BOD (Qi), Treatability Constant (K30/25), Depth of actual filter (D2), Volumetric flow per unit area (Qv) & Empirical Constant (A0). With our tool, you need to enter the respective value for Influent BOD, Treatability Constant, Depth of actual filter, Volumetric flow per unit area & Empirical Constant and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.