Credits

Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1000+ more calculators!
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has verified this Calculator and 100+ more calculators!

C Parameter (LTL) Solution

STEP 0: Pre-Calculation Summary
Formula Used
c_parameter = Admittance*(1+(Admittance*Impedance/6))
C = Y*(1+(Y*Z/6))
This formula uses 2 Variables
Variables Used
Admittance - Admittance is the mathematical inverse of the impedance. (Measured in Mho per Meter)
Impedance - Impedance (Z), in electrical devices, refers to the amount of opposition faced by the direct or alternating current when it passes through a conductor component, circuit, or system. (Measured in Ohm)
STEP 1: Convert Input(s) to Base Unit
Admittance: 5 Mho per Meter --> 5 Siemens per Meter (Check conversion here)
Impedance: 0.6 Ohm --> 0.6 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
C = Y*(1+(Y*Z/6)) --> 5*(1+(5*0.6/6))
Evaluating ... ...
C = 7.5
STEP 3: Convert Result to Output's Unit
7.5 Siemens -->7.5 Mho (Check conversion here)
FINAL ANSWER
7.5 Mho <-- C parameter
(Calculation completed in 00.016 seconds)

10+ ABCD Value Calculators

Characteristic Impedance Using B Parameter (LTL)
characteristic_impedance = B parameter/(sinh(propagation constant*Length)) Go
Admittance Using B Parameter (LTL)
admittance = (((B parameter/Impedance)-1)*6/Impedance) Go
C Parameter (LTL)
c_parameter = Admittance*(1+(Admittance*Impedance/6)) Go
B Parameter (LTL)
b_parameter = Impedance*(1+(Impedance*Admittance/6)) Go
Propagation Constant Using D Parameter (LTL)
propagation_constant = acosh(D parameter)/Length Go
Impedance Using D Parameter (LTL)
impedance = (D parameter-1)*(2*Admittance) Go
Impedance Using A Parameter (LTL)
impedance = (A parameter-1)*(2*Admittance) Go
Admittance Using D Parameter (LTL)
admittance = 2*(D parameter-1)/Impedance Go
A Parameter (LTL)
a_parameter = 1+(Impedance*Admittance/2) Go
D Parameter (LTL)
d_parameter = 1+(Impedance*Admittance/2) Go

C Parameter (LTL) Formula

c_parameter = Admittance*(1+(Admittance*Impedance/6))
C = Y*(1+(Y*Z/6))

What are the 4 parameters of a line?

The transmission line has mainly four parameters, resistance, inductance, capacitance, and shunt conductance. These parameters are uniformly distributed along the line. Hence, it is also called the distributed parameter of the transmission line.

How to Calculate C Parameter (LTL)?

C Parameter (LTL) calculator uses c_parameter = Admittance*(1+(Admittance*Impedance/6)) to calculate the C parameter, The C Parameter (LTL) formula is defined as a generalized line constant. also known as an open circuit conductance. It is used for determining the performance of input, output voltage, and current of the transmission network. C parameter and is denoted by C symbol.

How to calculate C Parameter (LTL) using this online calculator? To use this online calculator for C Parameter (LTL), enter Admittance (Y) and Impedance (Z) and hit the calculate button. Here is how the C Parameter (LTL) calculation can be explained with given input values -> 7.5 = 5*(1+(5*0.6/6)).

FAQ

What is C Parameter (LTL)?
The C Parameter (LTL) formula is defined as a generalized line constant. also known as an open circuit conductance. It is used for determining the performance of input, output voltage, and current of the transmission network and is represented as C = Y*(1+(Y*Z/6)) or c_parameter = Admittance*(1+(Admittance*Impedance/6)). Admittance is the mathematical inverse of the impedance and Impedance (Z), in electrical devices, refers to the amount of opposition faced by the direct or alternating current when it passes through a conductor component, circuit, or system.
How to calculate C Parameter (LTL)?
The C Parameter (LTL) formula is defined as a generalized line constant. also known as an open circuit conductance. It is used for determining the performance of input, output voltage, and current of the transmission network is calculated using c_parameter = Admittance*(1+(Admittance*Impedance/6)). To calculate C Parameter (LTL), you need Admittance (Y) and Impedance (Z). With our tool, you need to enter the respective value for Admittance and Impedance and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate C parameter?
In this formula, C parameter uses Admittance and Impedance. We can use 10 other way(s) to calculate the same, which is/are as follows -
  • a_parameter = 1+(Impedance*Admittance/2)
  • b_parameter = Impedance*(1+(Impedance*Admittance/6))
  • c_parameter = Admittance*(1+(Admittance*Impedance/6))
  • d_parameter = 1+(Impedance*Admittance/2)
  • admittance = 2*(D parameter-1)/Impedance
  • impedance = (D parameter-1)*(2*Admittance)
  • propagation_constant = acosh(D parameter)/Length
  • admittance = (((B parameter/Impedance)-1)*6/Impedance)
  • characteristic_impedance = B parameter/(sinh(propagation constant*Length))
  • impedance = (A parameter-1)*(2*Admittance)
Where is the C Parameter (LTL) calculator used?
Among many, C Parameter (LTL) calculator is widely used in real life applications like {FormulaUses}. Here are few more real life examples -
{FormulaExamplesList}
Share Image
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!